Filter Results By:

Products

Applications

Manufacturers

Enclosures

Surround and hold test elements.


Showing results: 451 - 465 of 701 items found.

  • Portable Trace Oxygen Analyzer

    7100P - Bacharach, Inc.

    The Neutronics 7100P Portable Trace Oxygen Analyzer is a portable analyzer designed for trace oxygen gas measurement in pure gases such as nitrogen, argon, and helium. This analyzer features a rapid-response mini-zirconia sensor with a measurement range of 0 to 1000 ppm oxygen. Extremely fast response, high accuracy, and simple calibration make this portable analyzer a low-maintenance solution that delivers reliable performance in a rugged light-weight steel enclosure.

  • Adjustable Leg Kit For The 20" Platform, 27 - 36", Supports 350 Lbs.

    310113566 - Virginia Panel Corporation

    The legs are designed to alleviate added weight from your enclosure by giving the platform extra support. Each kit includes two legs which have a mounting block for attachment to the receiver platform. The legs are adjustable in height from 27 inches to 36 inches in 1 inch increments using the telescoping feature of the legs. The leveling guide can be adjusted to exact heights between the 1 inch increments.

  • Energy Probes

    RjP-600 Series - Laser Probe Inc.

    The RjP-600 Series energy probes integrate the detector and preamplifier in the same enclosure, thereby maximizing signal integrity between the detector and preamplifier. This permits longer cable runs between the probe and instrument, as is often necessary in production environments. Probe specific information, like calibration date and wavelength response curves, is stored in the probe for access by the instrument. Other features include interchangeable filter holders and ¼-20 mounting hole.

  • Ingress Protection – Dripping Water Tests (IPX1 and IPX2)

    Keystone Compliance

    Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests is called the dripping water test. These tests are numbered IPX1 or IPX2. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the dripping water ingress protection test, would always be either a 1 or a 2.

  • Level Switches

    Whitman Controls

    We are a level switch provider offering a highly diversified offering of level switches and sensors, rangingfrom simple single and multi-level liquid level switches to more advanced sensortechnologies used in the measurement of liquids and solids across more ruggedmedia applications. These devices come in numerous sizes and materials, with ourmore advanced vibrating forks and rods providing numerous electrical settings,fittings, and various enclosures for more hazardous environments.

  • Conductor Damage Test Set

    CD-2M - Lumetronics

    Is designed to carry out tests specified for Switches used for Domestic and similar applications as included under IS:3854:1997. It is used to ensure that Screwtype terminals of switches are such that they clamp the conductor without causing undue damage to the conductor strands. It is a compact and robust andequipment housed in a bench top enclosure. The CD-2M is motorized to allow easy operation. The Instrument is designed to meet the requirements of IS:3854:1997 and other related specifications.

  • Data Logger

    QuadThermoVault - MadgeTech, Inc

    The QuadThermoVault is a four channel thermally insulated, battery powered, oven temperature data logger able to withstand extreme temperatures. It can withstand oven temperatures of up to 662ºF for up to 25 minutes when properly sealed. Its stainless steel enclosure and thermal properties lend itself to be the ideal temperature data recorder for applications such as powder coating cure ovens, wet coating cure ovens, batch ovens and conveyor ovens.

  • Frequency Sensor

    DARE Electronics

    DARE?s frequency sensors and monitors are available in both AC powered and DC powered models in a wide variety of standard or custom enclosures. Used in aircraft, ground support equipment (GSE), ground power applications, and other military and industrial applications, DARE frequency sensors, monitors, and frequency sensing relays will protect equipment that is sensitive to fluctuations in power line frequency from damage due to over and / or under frequency conditions.

  • RTM ThermalBlade

    F9 Systems, Inc.

    This ATCA compatible design offers the flexibity to verify the thermal characteristics of your Advanced TCA chassis, logic cards and backplane designs. Used in conjunction with the ThermalBlade the RTM emulates a typical rear mounted logic card. Application component heights and features, airflow resistance and enclosure power dissipation can be evaluated and analyzed.Maximum sustainable watts are 113 with two switches turned on. Watts are dissipated throughout the entire RTM ThermalBlade equally.

  • Anechoic Chambers

    Eckel Noise Control Technologies

    Anechoic Chambers are echo-free enclosures with a sound energy absorption level of 99% to 100%, or a reflected sound pressure level of 10% or less. The frequency at which the energy absorption drops below 99%, or the pressure reflection exceeds 10%, is known as the low-frequency cut-off. Sound absorption is obtained by lining the walls, ceilings, and floor with wedges or other sound absorbing elements or SuperSoft panels, depending on performance level required and cut-off desired.

  • Fixed Digital Gas Detector

    OLCT 10N - Teledyne Gas & Flame Detection

    The OLCT 10N is a digital combustible gas detector designed for to detect combustible, toxic gases or oxygen. Intended for use in combina​tion with the MX 16, MX 32 and MX 43 controller, the OLCT 10N provides a fast and accurate response.All transmitter information is received by the controller in less than 1 second.Non-intrusive operator interface requires only a simple magnetic wand and allows ​one man calibration without opening the enclosure.

  • System Switch with High Performance DMM

    3700A - Tektronix, Inc.

    The Model 3706A system switch with high performance DMM contains six slots for plug-in cards in a compact 2U high enclosure that easily accommodates the needs of medium to high channel count applications. When fully loaded, a mainframe can support up to 576 two-wire multiplexer channels for unrivaled density and economical per channel costs. The result is a tightly integrated switch and measurement solution that’s equally at home on the bench or in the rack.

  • Ingress Protection: Immersion Water Tests (IPX7 and IPX8)

    Keystone Compliance

    Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves immersing the equipment under test (EUT), in water. These tests are numbered IPX7 and IPX8. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the immersion ingress protection test, would always be a 7 or an 8.

  • Bench-Top LPR Data Logger

    MS6200L - Metal Samples Company

    The MS6200L is a bench-top data logger capable of measuring and storing data from all types of linear polarization resistance (LPR) corrosion probes. The instrument is microprocessor-based and features a simple, menu-driven interface using a 2-key keypad and a 2-line LCD display. It is housed in a rugged but lightweight plastic enclosure and is ideally suited for use in laboratory environments. The adjustable handle can be used for carrying the unit, or can be used as a tilt stand to adjust the viewing angle.

  • Vibrating Forks / Rods

    Whitman Controls

    We provide a highly diversified offering of level switches and sensors, ranging from simple single and multi-level liquid level switches to these more advanced sensor technologies used in the measurement of liquids and solids across more rugged media applications. These devices come in numerous sizes and materials, with our more advanced vibrating forks and rods providing numerous electrical settings, fittings, and various enclosures for more hazardous environments.

Get Help