Impedance
-
product
Mini Coax, Contact, ITA, Solder Sleeve, RG316 & RG178
610103140
Mini Coax, Contact, ITA, Solder Sleeve, RG316 & RG178.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Solder SleeveInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 2 GHzVSWR ≤ 1.2 @ 2 GhzInsertion Loss ≤ 0.05 dB @ 500 Mhz≥ -0.3 dB @ 2 GhzDWV 1500 VDC Min.Contact Resistance < 5 mΩ @ 0.5 Amp & always < 10 mΩCable Specifications RG316 & RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Precision Impedance Meter
1689
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.
-
product
Battery Impedance Tester
KVBT-15S
KV Hipot Power Test Equipment Co.,Ltd
Battery Internal Resistance Tester with advanced AC discharge measurement method, is applied to test accurately the voltage and resistance of battery capacity and state.
-
product
PNMDF3.5F NMD 3.5mm F to 3.5mm F Adapter
PNMDF3.5F Adapter, NMD 3.5mm F to 3.5mm F, Frequency ,Range: up to 26.5 GHz, Impedance: 50 Ohm
-
product
Coax, Contact, Receiver, 75 Ohm HD, sm59/U Belden 1855A, 3 GHz
610102133
Primary mating contact 610102132. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Female & Male Shield – BrassCenter Contact – BeCuContact Plating Center Conductor Shield – 30µ” Au over 100µ” NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 2.0 lbs max [0.91 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR ≤ 2.26 @ 3 GHzInsertion Loss -0.86 dB MaxDWV 1500 VDC min.Contact Resistance 5 mΩ center/ 3 mΩ outer Cable Specifications sm59/U Belden 1855AEnvironmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition EInsulation Resistance 1000 MΩ min.
-
product
Impedance Analyzers
HTF-1100.
A laboratory furnace used specifically for the electrical characterization of materials and also for heat treatment between ambient temperature and 1100 °C.
-
product
Mini Coax, Contact, Receiver, RG316
610104114
Primary mating contact 610103115. (May mate with other ITA contacts, as well.)*This contact available as a patchcord only. Please select link below to configure a patchcord.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance ≤ 5 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Coax, Contact, ITA, 20 GHz, RG 223, Crimp, 90 Series Modules only
610102117
Primary mating contact 610102116. (May mate with other ITA contacts, as well.)20 GHz coax contacts have an impedance of 50 Ohms and a current rating of 5 amps.It is recommended to use SF142 to achieve 20 GHz and RG223 to achieve 12 GHz.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 20 GHzVSWR 1.15 + .01 (f) GHz w/ RG142 (8 GHz)1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications RG 223 Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Vector Impedance Analyser
TE3000
The TE3000 Vector Impedance Analyser is a portable desktop instrument designed for high accuracy impedance measurement. The probe style construction and small output signal make it ideal for "in circuit" impedance characterisation of small signal devices without the risk of damage to the device under test. The TE3000 comes factory calibrated to the tip of the probe with optional custom calibration. Turn it on, set the frequency, take a measurement, and display the results in any format.
-
product
Antenna Analyzer
Measuring antenna SWR ratio with graphic display in a selected frequency range.Measuring antenna Impedance ( Z = R + j X )Measuring antenna resistance RMeasuring antenna reactance X, all the above with graphic display in a selected frequency range.Quick search for antenna resonance frequencyVery suitable for antenna measurement and adjustment.Portable and small size.Easy and intuitive operation
-
product
Micro Coax, Contact, ITA, RG316 Double Shield
610141104
Primary mating contact 610140104. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Controlled Impedance Field Solver
Si8000m
TheSi8000m is an all new boundary element method field solver , which builds on the familiar easy to use user interface in earlier Polar impedance design systems. The Si8000m adds enhanced modeling to predict the finished impedance of multiple dielectric PCB builds and also takes into account the local variations in dielectric constant on close spaced differential structures.
-
product
Vector Network Analyzer
Bode 100
With the multifunctional Bode 100 you get an exact picture of your electronic circuits and components in a frequency range from 1 Hz to 40 MHz. The Bode 100 is not only a state of the art Vector Network Analyzer, it also works as: Frequency Response Analyzer, Impedance Meter, Gain Phase Meter, Sine Wave Generator.
-
product
Mini Coax, Contact, ITA, RG178
610103130
Primary mating contact 610104141. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Impedance Analyzer
TH2839A
Changzhou Tonghui Electronic Co., Ltd.
■ Freq: 20Hz-5MHz, max. resolution 1mHz ■ Test Accuracy: 0.05% ■ Test Speed: Max.7.7ms ■ Auto-balance bridge technology, 4-terminal pair ■ High stability and consistency: up to 15 test ranges
-
product
Controlled Impedance Analyzers
HYPERLABS Controlled Impedance Analyzers can be used with various probes and adapters to quickly and reliably characterize impedance on PCB test coupons. These Test Systems are designed to comply with IPC-2141A standards for PCB coupon testing, and can be customized to meet specific customer needs.
-
product
IDM+
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
product
Micro Coax, Contact, Receiver, RG316 Double Shield
610140104
Primary mating contact 610141104. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor – SolderShield – SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss -√f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
EIS Interface (Electrochemical Impedance Spectroscopy)
BATT470m
The BATT470m electrochemical impedance analysis interface (EIS) provides an easy to use battery/cell impedance test platform for the electrochemical industry. Utilizing the highly accurate PSM3750 frequency response analyzer from N4L, the BATT470 provides impedance measurement of batteries/cells up to 100V DC. With a frequency range of 100mHz to 1MHz, the BATT470m covers a wide range of applications. Our software package - PSMComm2, featuring “EIS” mode, displays the in-phase and quadrature impedance of the cell in Nyquist form as well as overall impedance (Z), in bode form.
-
product
High Quality UCI - And Leeb-measuring Technology
SONODUR Product Family
Foerster Instruments, Incorporated
The non-destructive UCI test method (Ultrasonic Contact Impedance) as well as the Leeb test method enable fast and mobile measurement as a supplement to the classical hardness test. Due to the compact measuring probes and sensors of the SONO series, the devices can also be used in difficult test positions and with complex component geometries. Fields of application are e.g. incoming goods inspection, mix-up testing, production control, quality assurance, weld seam testing, cut edge testing, maintenance on installed components as well as the replacement of dynamic hardness testers for small material thicknesses (below 50 mm, e.g. boilers, tubes).
-
product
Precision Impedance Analyzer (20Hz to 10MHz)
ST2839
ST2839 series precision impedance analyzer is a new generation impedance test instrument by adopting the current international advanced automatic balance bridge principle. Its basic accuracy of 0.05%, the fastest test speed of 5.6ms, the frequency range of 20Hz-10MHz, and the impedance test range of up to 1GΩ can meet the testing requirements of components and materials, especially for low-loss (D) capacitors and high-quality Measurement of Factor (Q) Inductors. The four-terminal pair port configuration method can effectively eliminate the influence of the electromagnetic coupling of the test line, and expand the lower limit of the low-impedance test capability ten times lower than that of the conventional five-terminal configuration instrument.
-
product
Mini Coax, Contact, ITA, RG316
610103115
Primary mating contact 610104114. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 mΩ @ 0.5 Amp & always < 10 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
LCR Component Meter with Component Impedance Measurement
LCR45
The new LCR45 does everything that the popular LCR40 does, but we've added some significant enhancements. The LCR45 features a new high capacity micro and high resolution ADCs.*Fluid measurements of L, C and R (continuous readings with selectable hold function).*Fine resolution for improved performance at low inductance/capacitance/resistance.*Auto and Manual component type.*Auto and Manual test frequency.*Frequencies: DC, 1kHz, 15kHz and 200kHz.*Display of component values, complex impedance, complex admittance and magnitude/phase.
-
product
Calibration Kit
N911
*N911 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Mini Coaxial Contact, Receiver, RG316 Double Shield
610104149
Mini Coaxial Contact, Receiver, RG316 Double Shield.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Special Purpose Instruments
The Mechanical Impedance Sensor simultaneously measures an applied, driving-point force and response acceleration of a test structure for determining parameters such as mechanical mobility and mechanical impedance. The unit consists of a precision, shear mode accelerometer and a quartz force sensor in a common housing. Installation is primarily facilitated at the structural excitation points, in series with a stinger and vibration shaker.
-
product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V