Impedance
-
Product
LCR Meters & Impedance Measurement Products
LCR Meter
Hewlett Packard, Agilent and Keysight have contributed innovations and product excellence in impedance analysis for over half a century. Whether your application is in R&D, production, quality assurance, or incoming inspection, we take pride in contributing to your success. We strive to deliver complete solutions to meet your needs, from impedance analyzers to a wide variety of test accessories. Achieve success with Keysight’s impedance measurement solutions.
-
Product
Impedance Monitors
-
Single channel impedance monitorA flexible frequency generator/analyzerSupporting external load/potentiostat - TDI Dynaload RBL488 series & XBL series - WonATech WEL Load - Other 3rd parties potentiostat/galvanostat
-
Product
LISN Line Impedance Stabilisation Networks / AMN Artificial Mains Network
-
A LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network: *supplies the neccessary mains voltage (AC or DC) and current for the Equipment under Test (EuT).*couples interference voltage generated by the EuT and supplies it to the receiver.*provides well defined RF-impedance to the Equipment under Test (EuT)*keeps away unwanted disturbance coming from mains (filter)*protects the mains from unwanted disturbance voltage generated by the EuT
-
Product
High Impedance Differential Module
HID
-
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
WavePulser 40iX High-speed Interconnect Analyzer
WavePulser 40iX Series
Analyzer
WavePulser 40iX is the ideal single measurement tool for high-speed hardware designers and test engineers. The combination of S-parameters (frequency domain) and Impedance Profiles (time domain) in a single acquisition with a deep toolbox provides unmatched characterization insight of high-speed interconnects.
-
Product
Calibration Kit
N912
-
*N912 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Single Channel Potentiostats
PARSTAT Series
-
The PARSTAT-series of potentiostats is defined by offering superior performance as standard. The PARSTAT4000A and PARSTAT3000A complement each other.Both of these single channel potentiostats operate in VersaStudio software with all techniques available, including Electrochemical Impedance Spectroscopy up to high frequency.
-
Product
LCR Component Meter with Component Impedance Measurement
LCR45
-
The new LCR45 does everything that the popular LCR40 does, but we've added some significant enhancements. The LCR45 features a new high capacity micro and high resolution ADCs.*Fluid measurements of L, C and R (continuous readings with selectable hold function).*Fine resolution for improved performance at low inductance/capacitance/resistance.*Auto and Manual component type.*Auto and Manual test frequency.*Frequencies: DC, 1kHz, 15kHz and 200kHz.*Display of component values, complex impedance, complex admittance and magnitude/phase.
-
Product
Semiconductor Products
-
International Testware Corporation
International Testware supports all major ATE models for today's semiconductor products.CredenceAdvantestCaesarHewlett-PackardLTXIMSSchlumbergerAndo...and MANY moreTeradyneMosaidOur Solutions offer:Mixed-SignalEMI ReductionR/FCustom TailoredLow NoiseReliable PerformancePrecise Length MatchingSuperior Impedance ControlCrosstalk "Immunity"Minimal Inductance
-
Product
Medical Leakage Current Tester
2675Y
-
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
Product
Coax, Contact, Receiver and ITA, 40 GHz
610102114
Contact Adapter (Receiver/ITA)
The 40 GHz Coax contact is a blind mate connector that mates with 3.5 mm and 2.92 mm connectors. It is recommended to use 2.92 mm connectors for frequencies above 35 GHz. The temperature range is -50°C to +125°C.Mechanical SpecificationsDurability 20,000 cyclesContact Material Passivated stainless steel bodyberyllium copper contactsAu platedContact Plating Au platedContact Termination 2.92mm compatibleInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC – 40 GHzVSWR 1.35 DC - 18 GHz1.55 18 - 40 GHzInsertion Loss ≤ -0.3 dB @ DC - 18 GHz≤ -1.5 dB @ 18 - 40 GHzCable Specifications 2.92 mm CompatibleEnvironmental SpecificationsOperating Temperature -50°C to +125°C
-
Product
Battery Impedance Meter
-
Operation is fast and simple. Just press the spring-loaded probes onto the two poles of the battery. After 1.5 seconds, the unit beeps (indicating good contact) and displays the battery voltage and either the number of siemens or milliohms, depending on the knob setting. The display continues to show these numbers after the probes are removed; it resets only when the probes are pressed onto the next battery. The impedance and voltage of any battery between 1.2 and 60 volts can be read. Because of the wide range of voltages, even single low-voltage cells, such as NiMH, can be measured. The manufacturers of some batteries specify impedance in milliohms while other specify in siemens (one divided by the resistance in ohms). This meter will display both types of impedance for any given battery. Accuracy is +/- 2% of the value.
-
Product
Impedance Analyzers
HTF-1100.
-
A laboratory furnace used specifically for the electrical characterization of materials and also for heat treatment between ambient temperature and 1100 °C.
-
Product
Battery Impedance Tester
-
Weshine Electric Manufacturing Co., Ltd
The DC test method is adopted to simulate the actual use of the battery in a real and objective way, which can effectively eliminate the hidden dangers such as deficiency, deficiency and connection failure between batteries while measuring the internal resistance of the battery.
-
Product
Transducer Simulator
Model 7V
-
Impedance: 350 ohms nominal. Output Ranges:Fixed rotary switch: 0 to 3 mv/v in 6 steps of .5 mv/v .
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Impedance Meter, Audio, 200Ω, 2KΩ and 20KΩ scales
72-6948
-
Active device is essential for reliable installation of background music and paging systems in residences, offices buildings and public areas. Avoid costly service calls and amplifier damage by verifying actual speaker system impedance prior to operation. Unlike conventional volt/ohm meters, which measure DC resistance, this unit utilizes an internal 1KHz oscillator to measure true impedance. Accurately measure speaker lines that utilize impedance matching volume controls, switchers, transformers and passive crossovers. Because this unit accurately measures up to 20Kohm, it may also be utilized with 25V, 50V, 70V, and 100V speaker line transformers in commercial installations.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Micro Coax, Contact, Receiver, RG316
610140101
Coax Contact (ITA)
Primary mating contact 610141101. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outerCable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
Product
NM-SF 50 N-Male to SMA-Female Adapter
-
NM-SF 50 Adapter, N-Male to SMA-Female, Frequency Range: DC to 18 GHz, Impedance: 50 Ohm
-
Product
High Voltage Probe
CP-3308R
-
*100:1 scope probe *300MHz Bandwidth *Read out Function *Division Ratio x 100 *100MΩ Fix Input Impedance *1500V DC Working Voltage (CAT Ⅱ) *2000V AC peak to peak MAX. (CAT Ⅰ) *CE Approved.
-
Product
Calibration Kit
N911
-
*N911 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Handheld Electrochemical Battery Analyzer
EC-Series
-
Global Energy Innovations, Inc.
The EC1000™ and EC2000™ are the only handheld, Multi-Frequency, ElectroChemical Battery Analyzers on the market using CELScan™ technology. This means they can report both the Electrical (Impedance & Voltage) and Chemical (Sulfation and Dryout) properties of lead acid batteries (VLA, VRLA, GEL). Other battery types (NiCd, NiMH, Lithium-Ion and others) may also be tested using the EC1000™ and EC2000™.
-
Product
CellTest Multichannel Potentiostat
-
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
Product
Differential Probe
DP-16K Series
-
*High Frequency Performance Model*Bandwidth:(-3 dB)**DC~100 MHz (DP-16K)**DC~70 MHz (DP-16KM)**DC~50 MHz (DP-16KL)*2 Range: x100, x1000*Input Impedance:**10 MΩ // 10 pF each side to ground*Over Range Indicate LED*Rise Time: 4 ns
-
Product
Power Absorption Clamp
-
Beijing KeHuan Century EMC Technology Co,.LTD
Frequency Range: 30MHz-1GHz Typical Insertion Loss: 17 dB ± 4 dB Output Impedance: 50Ω Connector: N(f), 50Ω Maximum Current: 30 A
-
Product
Multifunction Meter for Electrical Installations
AMPI-525
-
*Short circuit loop measurement:*Impedance measurement with 23 A (44 A phase-to-phase), short circuit resistance RZW =10Ω*Measuring range: 95...440V, frequency 45...65 Hz*Short circuit loop measurement with resolution 0,01 Ω , without tripping the differential protections (I∆n ≥30mA)*Automatic short-circuit calculation, phase-neutral and phase-phase voltage detection





























