Impedance
-
product
Materials Test Systems
An impedance analyzer is a device that uses a programmable AC voltage / current source, together with voltage and current measurement circuits, to characterize sample impedance over a wide range of frequency. An example of this being the world famous Solartron Analytical 1260A Impedance Analyzer that provides EIS impedance characterization over more than 12 decades of frequency from uHz to tens of MHz. Impedance Analysis characterization is a key technology that enables new materials development for semiconductors, smart-materials, ferroelectrics, piezo-electrics, solid oxide, solid electrolytes, ceramics, polymers, OLED and many more materials.
-
product
Micro Coax, Contact, ITA, RG178
610141102
Primary mating contact 610140102. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG178Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Micro Coax, Contact, Receiver, RG316
610140101
Primary mating contact 610141101. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outerCable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Single Channel Potentiostats
12XX Series
The 12xx Series Potentiostats has two current models: the 1287A and 1280Z. This family of potentiostats communicate through trusted GPIB interface technology that can convert to USB for easy connection modern computers. The Solartron Analytical 1287A and 1280Z are often driven by CorrWare software for DC testing, such as Cyclic Voltammetry, and ZPLOT for AC testing, such as Electrochemical Impedance Spectroscopy.
-
product
Ground Pro Meter
Verifies Critical Grounding Parameters of a FacilityMeasures AC voltage, DC voltage, EMI voltage and AC impedanceProvides Accurate Measurements of Ground Impedance on a Working ToolMeets ANSI/ESD S20.20 requirements for AC impedanceIdentifies Potential EOS Generators
-
product
NF50 N-Female to N-Female Adapter
NF50 Adapter, N-Female to N-Female, Frequency Range: up to 6 GHz, Impedance: 50 Ohm
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Special - LISN
Impedance stabilization network which can be used to measure disturbance voltages of PLC (power line communication).
-
product
Transducer Simulator
Model 0V
SPECIFICATIONS: Impedance: 700 ohms nominal. Output Ranges: 10 turn vernier 0 - 3mV/V. Excitation: 20v ac/dc max,
-
product
Known impedance for use in loudspeaker measurements
Impedance Box
An impedance box is necessary for measuring the impedance of a loudspeaker. Listen Inc.’s impedance box contains a 0.25Ω resistance. This value is suitable for most loudspeakers, but may be easily swapped out for a different value by the user if speakers with a particularly high or low impedance are being tested. It is available with either XLR or 1/4″ balanced connectors. Please specify type of connectors when ordering.
-
product
RF Power Generators
MKS RF Power Generators provide reliable solid state power for thin films processing equipment. They are vital components of semiconductor fabrication systems, which produce the integrated circuits (ICs) or chips required by modern computers and electronic equipment. MKS RF Generators, combined with our Impedance Matching Network and our V/I Probe form a complete RF Delivery System.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Differential Probe
DP-800HS
*1:1 High Sensitivity*100 Gain Design*x1, x10, x100 Attenuator*Bandwidth: DC-50MHz*Input Impedance 3MΩ // 2.5PF*Max. 800Vp-p Input or ±400V DC or AC 280V RMS*Output Impedance 50Ω
-
product
Line-impedance stabilisation network
NNB 21 set
The NNB 21 line impedance stabilization network is designed for measuring of grid bound interferences of a device under test according to the satndard CISPR 25/ISO 7637. It measures the RF interference, which couples into the vehicle electrical system. Measurements during the development in a frequency range from 100 kHz to 1GHz can be carried out.
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
Impedance Analysis For E5061B-3L5 LF-RF Network Analyzer
E5007A
The E5007A provides the impedance analysis (ZA) firmware for the E5061B LF-RF network analyzer. This option enables the analyzer to measure impedance parameters of electronic components such as capacitors, inductors, and resonators. The combination of NA and ZA capabilities further enhances the analyzer’s versatility as a general R&D tool. Basic ZA functionalities including fixture compensation and equivalent circuit analysis are supported by the firmware. The DC biased impedance measurement is possible with the built-in DC bias source provided by the E5061B-3L3/3L4/3L51.
-
product
High Voltage Probe
HVP-40M
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
product
High Voltage Meter
STME-VM
Statclean Technology (S) Pte Ltd
This is a High Input Impedance Voltmeter with 70 Gigohm input impedance. Capable of measuring up to DC voltage up to +/-5.5kV with 1.0V resolution over a range of himidity and temperature, the meter measures with better than 1% accuracy without loading the power source. Its compact size and light weight body allows applications in laboratory and field work when powered by battery.
-
product
LISN Line Impedance Stabilisation Networks / AMN Artificial Mains Network
A LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network: *supplies the neccessary mains voltage (AC or DC) and current for the Equipment under Test (EuT).*couples interference voltage generated by the EuT and supplies it to the receiver.*provides well defined RF-impedance to the Equipment under Test (EuT)*keeps away unwanted disturbance coming from mains (filter)*protects the mains from unwanted disturbance voltage generated by the EuT
-
product
Broadband Dielectric Spectroscopy
Material Sensing & Instrumentation
Broadband Dielectric Spectroscopy is a powerful tool for investigating a variety of dielectric processes for both electrical and non-electrical applications. Also called Impedance Spectroscopy, the measurement separates molecular process on the basis of response time, providing a unique relaxation frequency along with a signature variation with frequency.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
Mini Coax, Contact, Receiver, RG178
610104141
Primary mating contact 610103130. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance ≤ 5 mΩCable Specifications RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Precision Impedance Analyzer
TH2851-015
Changzhou Tonghui Electronic Co., Ltd.
■ Test frequency: 10Hz-15MHz ■ High precision: using automatic balance bridge technology, four-terminal pair test configuration
-
product
Multi Function Testers
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
product
Coax, Contact, Receiver, 20/26 GHz, SF142B, 90 Series modules only
610102109
Primary mating contact 610102110. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 OhmsFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications SF142B Environmental SpecificationsOperating Temperature -65°C to +125°Vibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Mini Coax, Contact, ITA, RG316 Double Shield
610103152
Mini Coax, Contact, ITA, RG316 Double Shield.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
High Definition Arbitrary Waveform Generator
T3AWG Series
T3AWG3K Series consists of six high definition high performance Arbitrary Waveform Generators (HD AWG) consisting of 2, 4 and 8 channels, 16 bit vertical resolution, 12 Vpp max output voltage (50Ω into 50Ω), 128 Mpts/ch memory (optional 1 Gpts/ch), a maximum sampling rate of 1.2 GS/s and a max sinewave frequency of 250 MHz and 350 MHz respectively. The baseline HW voltage offset capability provide the unmatched ability to generate ±24 V or 48V output voltage window (50Ω into High Impedance).
-
product
Power Absorption Clamp
Beijing KeHuan Century EMC Technology Co,.LTD
Frequency Range: 30MHz-1GHz Typical Insertion Loss: 17 dB ± 4 dB Output Impedance: 50Ω Connector: N(f), 50Ω Maximum Current: 30 A