Compensators
-
product
wavefront sensor
HASO3 FAST
Our HASO3 Fast Shack-Hartmann wavefront sensors provide fast accurate and reliable measurements by uniting the standard HASO family's standard functionalities that customers have come to rely on, including absolute measurement, unequalled accuracy and insensitivity to vibration, with an acquisition speed of 905 Hz and a spatial resolution of 14 x 14 microlenses.When coupled with our HASOv3 software package, you can perform both zonal and modal wavefront reconstruction; calculate the PSF*, MTF* and Strehl ratio*; visualize the spot diagram; and obtain the M* parameter. Adaptive optics users can take advantage of our CASAO software package to control adaptive optics loops to compensate for atmospheric turbulence, optimize the focal spots of laser beams and Freespace communications.
-
product
Automatic Capacitance Inductance Tester
HTRG-H / 397
Wuhan Huatian Electric Power Automation Co., Ltd.
Measure each phase capacitance, total capacitance and inductance of compensation capacitor.
-
product
LV Iron Core Shunt Reactors
Iron core Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system. Shunt Reactors are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. Shunt Reactors can be directly connected to the power line or to a tertiary winding of a three-winding power or distribution transformer.
-
product
Precision Multi-Functional Manometer
DM 9600
Large 2.8” Color, touch screenTemperature compensated pressure sensorAutomatic zeroing for long-term stabilityTwo (2) K type thermo-couple socketsSimultaneous display of pressure and temperature readings1000 points and 500 sites data memoryMicro SD card slotUSB charging and data downloadHands free operation via magnetic back case20-hour Lithium battery
-
product
Oscilloscope Probe Kit
6HP-9060
Switchable X1/X10/X100 attenuation with reference switch positions. Break-resistant center conductor & wide compensation range. Flatter response, sharper leading edges. Faster rise time and replaceable cable probe head tip and ground lead. Max. input voltage: 600V/1200V (DC-peak AC). Includes BNC adapter, IC tip, insulating tip & trimming tool.
-
product
Gas Flow Sensors
ESRF-ESF Sensor
ESRF-ESF is one of the few gas flow sensors featuring bidirectional gas flow sensing of up to ±300 ln/min with a total error band of < 1.25% RD. ESRF-ESF gas flow sensors provide calibrated and temperature compensated output on an SPI, I2C bus or analog output making them plug & play for direct interfacing to low voltage MCUs and systems. The user is provided with a multitude of interface and output options so that the right sensor configuration can be selected based on the specific requirements for each application.
-
product
Inclinometer Systems
Columbia Research Laboratories
Columbia Research Labs offers our standard Inclinometer System and our Differential Inclinometer System. The standard system includes a temperature compensated force balance inclinometer in conjunction with a power module and convenient digital display. It is available with either AC or DC Power supply input. The Differential System allows the customer to match the slope of two remotely located surfaces. The readout can be set to indicate the absolute tilt of either sensor or the differential angle between them.
-
product
Pressure Based Waves
5218
Measure pressure based Waves with the Aanderaa Wave Sensors- compact fully integrated sensors for measuring wave and tide conditionsThe 5218 wave sensor is designed to be mounted on the Aanderaa SeaGuard top-end plate or connected to SmartGuard using AiCaP CANbus or in other measurement systems using the RS-232 interface.The 5218R wave sensor sensor is designed for use with long cables by means of RS-422 full duplex interface.Both wave sensors are based on a silicon piezoresistive pressure sensor. The pressure measurements are sampled and temperature compensated by an advanced Digital Signal Processor.The wave sensor application areas are in fixed installations, either deployed in a seabed installation in shallow waters, or mounted onto a fixed structure in the upper water column.
-
product
Wide Dynamic Range Power Sensor, E-Series
E4412A
Fast measurement speed, up to 400 readings per second with the E4416AWide dynamic range (-70 dBm to +20 dBm)Calibration factors, linearity ana temperature compensations data stored in EEPROM Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to NIST Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
Bluetooth® Enabled Free Chlorine Equivalent (FCE ™) & Temperature Pen
UltrapenX2™ PTBT4
*Accuracy of up to ±0.3 ppm FCE*Calibration with pH and ORP Standard Solutions*Automatic Temperature Compensation*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Waterproof*Powered by One N Type Battery (Included)
-
product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
product
Barometers
Ideal for recording ambient changes in lab, monitoring conditions affecting sample analysis, and assisting in prediction of weather changesUnit includes a barometer, thermometer, clock, altitude adjustment, and weather symbol forecasting symbolsAdjustable altitude compensation from –900 to 3600 feet (–300 to 1200 meters)Barometric trend shows current reading, previous 1, 3, 6, and 12-hour readings in bar chart f
-
product
e-Compases
Designed to accurately detect the direction and magnitude of external magnetic fields, ST’s eCompasses use accelerometer measurements for tilt compensation, thus ensuring very accurate compass headings even when handheld or mobile devices are inclined.
-
product
GNSS Smart Antenna
iCON gps 70 series
For construction professionals, Leica Geosystems introduces the most efficient GNSS rovers, the Leica iCON gps 70 Series. With the iCON gps 70 T you can measure and stakeout points quicker than ever before without the need to keep the pole vertical and level the bubble. The combination of the latest GNSS technology and inertial measurement unit (IMU) equips the iCON gps 70 T with permanent tilt compensation and makes it resistant to any magnetic interference. Being fully calibration-free, the iCON gps 70 T is ready when you are – anytime, anywhere.
-
product
Temperature Data Acquistion
THERMES-USB RF
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.
-
product
Bluetooth® Enabled ORP/REDOX & Temperature Pen
UltrapenX2™ PTBT3
*Accuracy of ± 10 mV ORP*3 Calibration Options with Automatic Solution Recognition*Automatic Temperature Compensation in Calibration Mode*99.9% Pure Platinum Electrode*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type Battery (Included)*Waterproof
-
product
Dispersion Compensating Fiber
Dispersion compensating fiber from M2 Optics is used for correcting dispersion effects created over distances within G.652 single mode optical fibers. Offered in a 19" chassis for rack or benchtop use, these high quality testing platforms are easy to work with and provide consistent, repeatable results.
-
product
True RMS RF Millivoltmeter
3440A
The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.
-
product
Handheld Water Quality Meters
LAQUA PH220
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) - 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- °C & °F temperature readings- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
product
SparkFun Pulse Oximeter And Heart Rate Sensor
MAX30101 & MAX32664 (Qwiic)
The SparkFun Pulse Oximeter and Heart Rate Sensor is an I2C based biometric sensor, utilizing two chips from Maxim Integrated: the MAX32664 Biometric Sensor Hub and the MAX30101 Pulse Oximetry and Heart Rate Module. While the latter does all the sensing, the former is an incredibly small and fast Cortex M4 processor that handles all of the algorithmic calculations, digital filtering, pressure/position compensation, advanced R-wave detection, and automatic gain control. We've provided a Qwiic connector to easily connect to the I2C data lines but you will also need to connect to two additional lines. This board is very small, measuring at 1in x 0.5in (25.4mm x 12.7mm), which means it will fit nicely on your finger without all the bulk.
-
product
Diode Power probe
The COMM-connect 3026 Diode based temperature compensated probe is designed for use with the COMM-connect range of Power Monitors. The probe will handle from 50µW to 100mW . Used with external couplers and the our measurement system application from 1W to 1MW, a high dynamic range can be configured. The 3026 Diode based probe gives excellent stable results along with the COMM-connect Power Monitor variants. This gives our customers a number of applications to monitor and control the last part of your RF network installation from transmitters to the antenna.
-
product
C-Band Separate Dispersion Compensation Raman Fiber Amplifier
DRA5228/F
Hangzhou Huatai Optic Tech. Co., Ltd.
Raman Fiber Amplifier (RFA) utilizes the optic gain in the Stimulated Raman Scattering (SRS) in the optical fiber and realizes the amplification of the signal optic. FRA, with very low equivalent noise and a wide gain scope, can further widen the gain bandwidth by adopting multi-wavelength optical bump, which represents the development direction of the new optical fiber amplifier.
-
product
Reference Standards
GF333V2
Beijing GFUVE Electronics Co.,Ltd.
Standard kWh meter is a reference standard with the characteristics of wide-range, multifunction and high-precision. It has accuracy class of 0.02. By adopting techniques of DSP, embedded system and automatic temperature balancing and other compensation, it has not only advantages of light weight, small size, high precision, high performance, powerful function, original interface, ease-to-use, but also work stability.The product can be widely used in fields of electric energy measuring, electric energy laboratories and other relevant industry, not only in laboratories but also at the industrial field.
-
product
Automatic Battery
BATLV800
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
product
Semiconductor Optical Amplifier
SOA
Amonics SOA is a polarization maintaining optical amplifier with high fiber-to-fiber gain. It is designed for transmitter applications to increase optical launch power to compensate for the loss of other optical devices. The benchtop version incorporates a user-friendly front panel housing a LCD monitor display, key switch, power control knob and optical connectors. RS232 computer interface is also equipped on the rear panel. 1MHz with 10ns pulse width intensity modulation is available. The OEM module version is an ideal building block for OEM system integration, especially in optical communication network and CATV applications. It requires only a single +5V power supply.
-
product
Solid State
4701 Series
The 4701 Model is a Non-blocking Full Fan-Out (any input connected to any output simultaneously) coaxial switching system operating from 1 GHz to 18 GHz. The system is configured with maximum (12) N-type inputs and (12) SMA-type outputs. All inputs are outfitted with high linearity amplifiers in order to compensate for system insertion loss.
-
product
Guardian Ground Bond Tester
19572
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
product
Hydrometer
DMA-35
Explorer Technology Group (ETG)
Reads specific gravity and temperature. Package includes; a custom carry case, operating instructions and a 6 month limited warranty. The DMA-35n will be configured to read the specific gravity of battery acid at 77F/77F compensation and fluid temperature in degrees Fahrenheit as standard.
-
product
Thin Film Based Thermopile Detector: 2 or 1 Channels
DR46
A two-channel or a one-channel compensated thin-film thermopile in a TO-8 package. Each active area is 4mm x 0.6mm. Offers high output with excellent signal-to-noise ratio. An internal aperture minimizes channel-to-channel crosstalk increasing sensitivity.





























