Compensators
-
product
Conductivity / TDS Monitor / Controllers
750 Series II Conductivity Monitor & Controllers
The unique circuitry of the 750 Series II Conductivity Monitor/controllers guarantees accurate and reliable measurements. Drift-free performance is assured by “field proven” electronics, including automatic DC offset compensation and highly accurate drive voltage. Since temperature compensation is at the heart of accurate water measurement, all Myron L® Monitor/controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models corrected to 25°C. The TC may be disabled to conform with USP requirements.
-
product
USB Temperature Measurement Bundle
The USB Temperature Measurement Bundle includes a CompactDAQ Chassis with the C Series Temperature Input Module for temperature measurements. The USB Temperature Measurement provides a portable, USB-based sensor measurement system with features such as anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
product
In-situ Wafer Temperature Monitoring
CI Semi's family of noncontact temperature monitors (the NTM line), offers high end pyrometry products for the measurement of wafer temperatures during process. CI Semi’s flag ship of the line, the NTM Delta, incorporates real-time, same point emissivity measurement and compensation making it the ideal solution for in situ monitoring for processes such as RTP, CVD and PVD. The NTM family is sold to leading tool manufacturers.
-
product
IR Thermometers
Is a sensor that consists of a lens to focus the infrared (IR) energy on to a detector, which converts the energy to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature variation.
-
product
UHF True RMS Probe
The UHF True RMS Probe is a frequency compensated power probe capable of measuring power even in a multiple carrier installation. Regardless of physical waveform, the probe will measure the True RMS power of the signal. When used together with our Broadcast Power Monitor type 3024, you can add Web and SNMP capabilities to your mast site installation.
-
product
Capacitor for AC Filtering
PECA4 (690V)
Lifasa - International Capacitors, SA
These capacitors are especially suitable for applications where high levels of AC voltage are required. The design of this series has been optimized for the manufacture of high performance AC filters for compensation equipment with high pollution such as UPS or wind turbines.
-
product
Automatic Batteries with Filters with Thyristors
BATLVFS800
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of powerfactor in low voltage instalations.
-
product
Analog Power Modules
Renesas' family of analog power modules offers users a fully integrated DC/DC switching buck converter in one package. These modules combine the controller, power FETs, output inductor, and compensation circuitry in a single package minimizing both the external component count and complexity of converter design.
-
product
MAX PH/ORP/Temp Logging Bench Meter
MW151
The Milwaukee MW151 MAX 3-in-1 pH/OPR/Temp. Logging Portable Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design with a small lab footprint. The MW151 MAX is accurate to ± 0.002 pH with automatic or manual temperature compensation with a built in dedicated GLP key. Ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
product
CAT-5 Cable Equalizers
Analog Devices high speed, differential receivers and CAT-5 cable equalizers compensate for the transmission losses of UTP and coaxial cables up to 300 meters in length. Our design techniques for products such as the AD8123 optimize performance for low noise, short-to-medium range applications, while also providing the high gain bandwidth required for long cable equalizations. Various gain stages are summed together to best approximate the inverse frequency response of the cable. Logic circuitry controls the gain functions of the individual stages so that the lowest noise can be achieved at short-to-medium cable lengths.
-
product
Pressure Transmitter For Industrial Applications, Ratiometric Output
Series 21 C
KELLER AG für Druckmesstechnik
The C-series transmitters are noted for their ability to deliver high accuracy over a wide temperature range. This is achieved by means of mathematical modelling of the sensor characteristics and digital compensation. In order to do this, each transmitter is gauged over pressure and temperature, programmed and checked after calibration in the same test set-up.
-
product
Salinity Meter with Electrode
Salt 6+
Automatic Temperature Compensation (ATC) for the optimum accuracy under fluctuating temperatures :: Hold Function momentarily freezes reading for easy viewing and recording
-
product
Thermocouple Data Logger
IM2000 Series
We have been offering IM2000 Series Thermocouple Data Logger with direct interfaces for various types like J / K / R / S / T / B / E etc. Loggers have built in ambient compensation. The thermocouples are most commonly used sensors for measuring temperature in process industries. These can take any form and are available in various mechanical shapes. The temperature ranges are varied.
-
product
Dual Wavelength Multimode Light Source
FiberLink 6652
The Fiberlink 6652 Dual Wavelength Multimode Light Source is a cost effective, compact, handheld light source. The temperature compensated outputs are calibrated to couple -20dBm of optical power into multimode fiber.
-
product
Trace-Level UV Fluorescence SO2 Analyzer
Model T100U
Teledyne Advanced Pollution Instrumentation
The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.
-
product
Multibeam Echosounder - Deep Water
SeaBat 7160
The SeaBat 7160 transducer array is comprised of linear receive and transmit arrays mounted together on a support base. The T-shaped array geometry provides the basis for a compact, high-resolution sonar which is easily installed for portable or hull mounts – a first for a high-resolution system in this frequency range. The system features a pitch-stabilized transmitter and an active roll compensated receiver.
-
product
Radius Radiation Probe
Hawk Radius®
The Hawk® Radius is a ruggedized solution for monitoring both ambient and elevated levels of ionizing radiation. Like a Hawk with its remarkable vision, the Hawk Radius Probe “sees” things that other probes cannot. The high sensitivity weatherized pancake sensor can provide early warning of changing ambient radiation conditions, while the energy compensated detector can accurately report penetrating gamma radiation dose rate at elevated levels. Radius probes are typically deployed as part of an environmental radiation monitoring program, or for safety and security systems. In its standard configuration the probe detects beta, low energy gamma and x-radiation with one channel and energy compensated penetrating gamma radiation levels with a second channel. It can be configured to detect alpha radiation as well. The Hawk® Radius has been deployed worldwide in demanding conditions for protecting communities and collecting environmental radiation data. It can be deployed easily and requires minimum maintenance. The Radius is compatible with Medcomʻs GeigerLink adapter and the IMI Gateway App for use with personal computers. It can also be used with most data loggers including popular Campbell Scientific models.
-
product
Special Purpose Probes
6100 Series
Similar to a standard 10X scope probe except with BNC connections on both ends. With BNC connections on both ends, it provides a more stable connection when connecting to other equipment. This eliminates the use of a standard probe with a BNC adapter on the probe end that could come loose or break off the probe tip. The lead can be compensated to your scope with the trimmer tool included.
-
product
Time Delays
Analog Devices time delay products feature delay control modulation bandwidth up to 2.5 GHz, as well as a 0 ps to 70 ps continuously adjustable delay range for some members of this portfolio. Monotonic delay compensation allows for stable operation over both power supply and temperature variations.
-
product
External Pre-amplifiers
Although all Spectrum A/D cards have a very powerful input section with a highly configurable input amplifier and a variety of input ranges it is sometimes necessary to have additional external amplifiers if the signal to acquire has an extremely low level. Spectrum offers a range of perfectly matching external amplifiers to cover such cases. These powerful amplifiers have been rated using the Spectrum cards and offer best performance together with high amplification rates.The amplifiers are simply connected between the signal source and the Spectrum A/D card input and can be manually switched between different settings using small lever keys. All amplifiers allow the offset compensation by using an adjustable screw.
-
product
Handheld Digital Manometer
477AV
Measures Pressure, Flow and Velocity; ±0.5% Accuracy. The SERIES 477AV Handheld Digital Manometer is now available with pressure, flow, and velocity measurements along with a number of other convenient features. The built-in air velocity and flow calculations provide accuracy and conserve time and error associated with manual calculations. Also featured on this unit are adjustable zero and span values for calibrating in the field, as well as a damping feature to compensate for the fluctuating of readings.
-
product
TMR Current Sensors
MultiDimension Technology Co.,Ltd.
An open-close current transducer, high sensitivity and signal-to-noise ratio TMR chips are used in the design, which based on Tunneling magneto resistance effect. The transducer has a built-in temperature compensation and nonlinear compensation circuit, which can accurately measure DC, AC and pulse current. The transducer has many benefits ,such as high precision, wide bandwidth, low power consumption, excellent isolation performance and so on. Besides, the design of open-close structure makes it easier to install and unload.
-
product
Gas Filter Correlation CO2 Analyzer
Model N360
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Capacitor Duty Contactor
ENTES Capacitor Duty Contactors are specially designed for the control of capacitors in compensation panels.
-
product
PDS Motionscan Software
Allows a 3D Scanning sonar user to collect motion compensated 3D point clouds from a moving platformTeledyne PDS MotionScan system allows a 3D Scanning sonar user to collect motion compensated 3D point clouds from a moving platform. The MotionScan system is comprised of: an RTK capable dual antenna GPS with precision heading output, a heave, pitch and roll sensor, a topside control console. In combination with a BlueView 3D Multibeam Scanning Sonar this creates a full survey package.
-
product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
product
12 Channels 1.0 ~ 17.0 Gb/s (200Gbps) Pulse Pattern Generator and Error Detector
CA9806-12
The UC INSTRUEMNTS CA9806-12 is a highp erformance, flexible 12 channels Pulse Pattern Generator and Error Detector that can operate from 1.0 to 17.0 Gb/s (200 G). It is combined with three sets CA9806 4 CH 1.0 to 17.0 Gbps Pulse Pattern Generator and Error Detector that incorporates an external one by 4 rate clock synthesizer. Its small size allows it to be placed close to the device under test, it can also be placed further away using the TX driver pre and post emphasis controls features to compensate for cable and interconnect losses. It also has a non destructive, integrated eye outline capture feature along with a quick eye height and width measurement capability. Build-in 8.5 ~ 15 Gb/s eye diagram testing function.
-
product
Inertial Sensors
Our CV5 line of board-level OEM inertial sensors is ideal for platform stabilization, precision agriculture, terrain compensation, and more. Their small footprint and low weight enable them to install easily into almost any application. Our CV5-25 AHRS, CV5-15 VR, and CV5-10 IMU sensors offer industrial-grade precision at a fraction of the cost.
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.