Compensators
-
Product
Smart Power Stage
-
Renesas Smart Power Stage (SPS) modules have integrated high accuracy current and temperature monitors that can be fed back to the controller and doubler to complete a multiphase DC/DC system. They simplify design and increase performance by eliminating the DCR sensing network and associated thermal compensation.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
Product
Compensating Reactor
RCTD
-
This module is properly designed for testing Tan Delta in rotating machines with TD 5000 and allows increasing the test current and getting the maximum test voltage with high capacitive burdens
-
Product
pH 5+ Handheld pH Meters
-
These meters are perfect for fast, accurate results. Automatic temperature compensation (ATC) ensures accuracy from 0 to 80°C. Meters include a protective rubber boot that also acts as a meter stand.
-
Product
Humidity Transducers & Transmitters
-
TE Connectivity (TE) offers packaged humidity and temperature sensors with voltage (analog) output signals. Designed for 2% accuracy in ranges from 10-95% relative humidity (RH), these sensors can be used for HVAC and air quality applications in which compensation for humidity is required. A specialized version for low RH settings is available.
-
Product
Ellipsometer
RC2
-
The RC2 design builds on 25 years of experience. It combines the best features of previous models with innovative new technology: dual rotating compensators, achromatic compensator design, advanced light source and next-generation spectrometer design. The RC2 is a near-universal solution for the diverse applications of spectroscopic ellipsometry.
-
Product
VIS/NIR Sensor
AF26
-
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
Product
E-Series Average Power Sensor
E9301A
Power Sensor
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Data Collector for Water Levels
DCX-22 AA
-
KELLER AG für Druckmesstechnik
The data collector DCX-22 AA measures and records ground water levels using KELLER's two sensor AA-technology (absolute-absolute). The submersible depth sensor measures the water level. Barometric pressure variations are measured and compensated with the built-in waterproof air pressure sensor which is mounted in the electronics housing at the top of the borehole.
-
Product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
-
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.
-
Product
Gas Filter Correlation CO Analyzer
Model N300
-
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Focus Control And Stabilization
-
Applied Scientific Instrumentation
The CRISP system is designed to maintain focus over time i.e. compensate for thermal & other factors that may cause the sample to drift out of focus over time. It also can be used to maintain a given focal point while scanning the sample in XY. If you are looking to find the optimal focal point while scanning through the sample in Z phase.
-
Product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
Dual Wavelength Multimode Light Source
FiberLink 6652
-
The Fiberlink 6652 Dual Wavelength Multimode Light Source is a cost effective, compact, handheld light source. The temperature compensated outputs are calibrated to couple -20dBm of optical power into multimode fiber.
-
Product
Toroidal Turns Analyzer
1000
-
International Electro-Magnetics, Inc.
The Model 1000 is designed to be used in production environments to test for actual turns on toroidal cores. It is able to test single winding toroids as well as multiple windings. It automatically compensates for variations in core permeability.
-
Product
EIS Battery Analyzer
BA8100
-
The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.
-
Product
Carbon Dioxide Sensor, CO2
ENVIROMUX-CO2
-
CO2 room sensor for periodically unoccupied areas. Measures CO2 in a range of 0 to 2,000 ppm. 0 to 5 VDC output. Continuous automatic air pressure compensation. LED indicators for operation status and system test. Maximum cable length: 1000 ft (305m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: RoHS.
-
Product
AC Resonant Test System
-
Yangzhou Power Electric Co., Ltd
Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
Product
Athermal FBG, Std/Mini Devices, Single/Double Ended
T95
-
Technica Optical Components, LLC
The T95 is a Wavelength Reference consisting of a Fiber Bragg Grating (FBG) encapsulated in a package that contains advanced materials effective at providing passive temperature compensation by matching the coefficient of temperature expansion (CTE) of the FBG’s fiber.
-
Product
Guardian Ground Bond Tester
19572
-
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
Product
Multibeam Echosounder - Deep Water
SeaBat 7160
-
The SeaBat 7160 transducer array is comprised of linear receive and transmit arrays mounted together on a support base. The T-shaped array geometry provides the basis for a compact, high-resolution sonar which is easily installed for portable or hull mounts – a first for a high-resolution system in this frequency range. The system features a pitch-stabilized transmitter and an active roll compensated receiver.
-
Product
Receivers and Sensors
-
Choose the optical receiver that meets your system performance and layout requirements. Add sensors for automatic compensation for environmental changes.
-
Product
Stand-Alone Doppler Current Sensor
DCPS
-
The Doppler Current Profiler Sensor (DCPS) is a medium-range, 600kHz current profiler smart sensor. It offers high-quality ocean current measurements and is ideally suited for cabling directly to various systems or dataloggers via serial or AiCap bus. With its integrated compensation for tilting and movement, the sensor is commonly used to measure current from buoys and other moving platforms.The 5400/5400R version of the current sensor is 300m depth rated, the 5402/5402R version is 4500m depth rated, and the 5403/5403R version is 6000m depth rated and intended for commercial as well as research use. It comes with an integrated temperature sensor that can be calibrated on request.As an extension to the DCPS, we now offer the current profiler with an integrated pressure unit called the 5400P. This version enables acoustic wave measurements in addition to profiling currents. Ideal for small observatories, the DCPS sensor is the market's lowest-cost current and wave sensor.
-
Product
Oxygen Gas Analyzer
KM 5490
-
Kusam Electrical Industries Limited
• As it uses a high quality oxygen sensor, it is very precise and its performance is stable.• It uses the advance technology design and has multiple functions.• With highlight backlight display and acousto-optic alarming, it is easily configured.• The in built temperature compensation makes the meter measure the correct value of oxygen in the environment temperature of -10 ~ 40�C.• As its case is ergonomically designed, it looks elegant, and is easy to carry.
-
Product
MAX PH/ORP/Temp Logging Bench Meter
MW151
-
The Milwaukee MW151 MAX 3-in-1 pH/OPR/Temp. Logging Portable Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design with a small lab footprint. The MW151 MAX is accurate to ± 0.002 pH with automatic or manual temperature compensation with a built in dedicated GLP key. Ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
Product
Temperature Data Acquisition
THERMES-USB
-
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
Product
CO2 Concentration
H5521
-
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Isocratic Pumps - Single Headed, Positive Displacement Piston Pumps
ReaXus MX Class
-
The economical MX Class consists of single-headed, positive displacement piston pumps incorporating additional features for challenging applications. With pressure capability up to 5,000 psi, the MX Class can be used in both analytical and smallscale preparative HPLC separations. Further applications include demanding metering and dispensing, as well as Sample Injection, Infusion, or Cone Wash for Mass Spectrometers. Standard fluid path material is Stainless Steel.Features include available pressure monitoring with automatic pressure compensation, Pulse Dampener, integrated Prime-Purge Valve, interactive keypad control, and complete PC control and status through RS-232 and Micro USB 2.0 ports. Requiring minimal bench space for the performance, the MX Class will easily integrate into most workspaces.





























