product
Data Logger Centesimal Thermometer
HD2127.2
Centesimal thermometer in the range ±199.99°C, decimal outside this range, 2 inputs for Pt100 probes with SICRAM module.
-
product
Micro-Surface Microprobe
ICT-4
ICT-4 Micro-Surface Microprobe - For use on integrated circuits and other micro specimens. 0.013'' diameter .5'' straight stainless steel shaft; slightly protruding sensor bead to facilitate temperature probing. 5'' tubular handle fits micro-manipulators. Maximum intermittent temperature 200°C, continuouse use 100°C, Time constant 0.025 Seconds. 5 foot lead. Not isolated.
-
product
Security/Detection
ST60 Dual
A two-channel silicon-based thermopile detector in a TO-5 package. Each small active area size is 0.61mm x 0.61mm. This is our lowest-cost and fastest time constant two-channel detector. It delivers a time constant of 18ms with Nitrogen encapsulation gas combined with a very low Temperature Coefficient of Responsivity of -0.04%/°C. This detector has a very short thermal shock response to ambient temperature change.
-
product
Cable Assembly, 9-Pin D-Type, Male to Unterminated With Tinned Ends, 1m, HV
A009DM5-T-HA100
A range of 9-Pin D-Type High Voltage cable assemblies with unterminated connections on one end, constructed from PTFE Type C insulated wire. The unterminated connections are coded to match the connector pin designation.
-
product
Digital Probe Thermometer
TA288
A multi-purpose thermometer for your laboratory, workbench or office. Simple to use and provides a clear digital readout in °C or °F. a sharp and sensitive metal probe, and a protective plastic sheath
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Satellite Communications Modems
satTRAC
satTRAC Modems provide RF conversion and modem processing for TT&C and Payload links with support for all commonly used frequencies and waveforms.
-
product
PS/2 Type Power Supply; ATX 500W
PS500-XP2
*Input Range: 90 ~ 265VAC Full Range*Output Voltage:**+5V, 24A (0.3A min)**+3.3V, 24A (0.5A min)**+12V, 34A (1A min)**+12V1, 17A (1A min)**+12V2, 17A (1A min)**-12V, 0.8A**+5Vsb, 2.5A*MTBF(hours): At 25°C 100,000h*Safety: TUV, CUL, CB, IEC60950-1, GB4943-2001, UL60950-1, EN60950-1*Dimensions: 150 x 140 x 86 mm*Compatible with Axiomtek products: AX61221/AX61222/AX60501/AX60551/AX60552/AX61400/AX6145/AX6156/AX61492/AX61220
-
product
AC Voltage Transducer
TD SERIES: AC
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C ± 5 °C• High Dielectric Strength 2.6KV AC / Min,Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
product
Cable Assembly, 50-Pin D-Type, Male to Unterminated With Ferrules, 0.5m HV, Exit Away From Pin 1
40-972-050-0.5m-MU-HV
50-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24 AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assembly can be secured to the mating part by a screwlock. The 50-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.
-
product
NI-9411, ±5 V to 24 V, 6 Differential/Single-Ended Channels, 500 ns C Series Digital Module
779005-01
±5 V to 24 V, 6 Differential/Single-Ended Channels, 500 ns C Series Digital Module - The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.
-
product
Thermalert Clinical Monitoring Thermometer
TH-8/AOP
The TH-8/AOP is one of our most economical precision thermometers in the Physitemp product line. The TH-8 offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-8 has a temperature range 0f -10 to +60°C with 3 probe inputs. The TH-8 is also switchable from celsius to Fahrenheit. The TH-8 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
product
Impulse Tester
MIG2412SPD
The MIG2412SPD is a impulse tester for testing SPD (Surge Protection Devices) in accordance with IEC 61643-1 and VDE 0675. Up to maximum 24kV/12kA making it suitable for testing Class I to III or in accordance with VDE Class A,C, D. The MIG2412SPD is a hybrid generator with a voltage wave shape 1,2/50 ìs at "no load" and a current wave form 8/20 ìs at short circuit for testing Class III (D) SPD connected to power line.
-
product
CTE Tester
CTE-360
The CTE-360 measures thermal expansion coefficients on wide range of materials over a temperature range of -20°C to 100°C. Although intended primarily for the study of materials used in electronic packaging applications, it can be used on virtually any solid, gel, paste, or viscous liquid over this temperature range.
-
product
AC/DC Power Supply 20 W
CFM21M090-S
AC/DC power supply with 20 W from Cincon | input ranges 90 - 264 VAC | output 9 V | operates in temperature from -25 to +70 °C | provides 2 MOOP safety and is class II | screw terminals
-
product
Temperature, Humidity, CO2 Transmitter
H6020
The regulators are designed for online measurement of temperature (C or F), relative humidity and carbon dioxide concentration of air without aggressive ingredients. Measured temperature andrelative humidity are recomputed to following humidity expression: dew point temperature, absolutehumidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Complete Solution for Developing & Testing Discrete Voltage-Level Interfaces
M4KDiscrete Module
The M4KDiscrete module provides a complete solution for developing and testing discrete voltage-level interfaces. The M4KDiscrete contains control I/O registers that are memory-mapped and may be accessed in real time. The module supports twenty programmable I/O discretes that can record or control the external discretes that are connected to it. In addition, the module can record changes in the input discrete with an associated time tag via a built-in FIFO. Output discretes are open collector, capable of handling up to 32V with a maximum sink current of 100 mA each. Ordering Information:The user can set each discrete:• Either as input or output.• Either to TTL (0 – 5V) or Avionics (0 – 32V) voltage levels on inputs and• Either enable or disable external debounce on inputsThere is a 4092 Word FIFO (a string of 1023 discrete entries) containing the data and time tags.The M4KDiscrete module is supplied with C drivers, including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application.
-
product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74C-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
MIL-STD-1553 A / B Test And Simulation 3U PXI Module
PXI-C1553
*Dual redundant*1, 2 or 4 channels*Simultaneous bus controller, 31 remote terminals, bus monitor*Error entry and detection*FPGA based hardware architecture*PXI trigger on 1553 bus events*10 programmable, discrete I / O (up to 30V)*IRIG-B timecode encoder / decoder with free-running mode*Real-time recording and physical bus playback*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, LabView Real-Time and other systems
-
product
CANdo Software Development Kit
SDK
The CANdo SDK (Software Development Kit) is designed to provide a quick & easy way of integrating the CANdo Interface into any Windows program, written in a programming language that supports Windows DLLs. Example projects are provided written in C, C++, C#, VB & Delphi.
-
product
USB-C® – USB 2.0 C Receptacle to A Plug
AUT17032-CRAP
This fixture is designed for USB-C 2.0 Plug and USB-A products.
-
product
Fibre Channel Software Development Kit
Fibre Channel SDK
Avionics Interface Technologies
Software Drivers for Windows, Linux, VxWorks, and other Operating Systems (on request) - Compatible with all Fibre Channel Interface Modules - Includes documented APIs with source code examples for ANSI C, C++, and LabVIEW - Support provided by AITs industry leading applications engineering team
-
product
PXIe-1486, 8 Input, 8 Output, or 4 Input/4 Output PXI FlexRIO FPD-Link™ Interface Module
787455-01
The PXIe-1486 combines the Texas Instruments Flat Panel Display Link™ (FPD-Link™) interface with the Xilinx FPGA for high-throughput vision and imaging applications. This module provides a high-speed digital interface for using and testing modern advanced driver assistance systems (ADAS) and autonomous drive (AD) camera sensors and electronic control units (ECUs). Additionally, the PXIe-1486 makes use of a combination of FPD-Link™ serializers and deserializers with a Xilinx FPGA to provide a high-throughput and customizable FPD-Link™ interface on PXI. The included FlexRIO driver, with LabVIEW FPGA examples, provides access and control for power-over-coax, I²C back-channel communication, and general-purpose input/output (GPIO) communication on the FPD-Link™ channels. The PXIe-1486 is ideal for applications such as in-vehicle data logging, lab-based playback, or hardware-in-the-loop (HIL). FPD-Link is a trademark of Texas Instruments.
-
product
Cable Assembly, 37-Pin D-Type, Male to Unterminated With Ferrules, 0.5m, HV
40-972-037-0.5m-FU-HV
The 37-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assembly can be secured to the mating part by a screwlock. The 37-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.
-
product
Miniature LVDT Position Sensors
Miniature LVDTs are ideal where reliable measurements are needed in small spaces. With options for venting up to 30,000 psi, and temperature ratings to 400°F (200°C), these LVDTs operate in hydraulic equipment, embedded in robotics, and used in harsh downhole conditions.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
K Thermocouple Immersion Probe
TP656/1
“K” Type thermocouple imemrsion probe. Tolerance according to IEC 60584-2 standard. °C max: 1000. Response time: 1 s.
-
product
NI-9470, 5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module
787089-01
5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module - The NI‑9470 is a digital output module that features proportional valve drive control. You can use the NI-9470 to perform pulse width modulation (PWM), dither control, and current readback. The NI‑9470 features eight output channels compatible with signals from 5 V to 30 V and transient overvoltage protection between the output channels and the backplane.
-
product
Microphone Pre-Amp Audio Interfaces
Analog Devices mic pre-amp audio interfaces provide a high fidelity, high performance solution for audio products. Specifications for this family include ultralow 1.5 dB noise figures, 140 dB gain range, and high gain capability. Operating in an extended industrial temperature range of –40°C to +85°C, this portfolio of mic pre-amp audio interfaces supports many applications, including precision instrumentation, active filters, low noise amplifier front ends, surveillance systems, computerized voice recognition, and a variety of other industrial and consumer products. As the first choice for serious audio engineers, Analog Devices mic pre-amp audio interfaces can give your applications the performance needed to meet the most demanding specifications.
-
product
2 kHz C Band Fast Swept Tunable Laser Source
CA92050-KT
The CA92050-KT 2 kHz fast swept tunable laser modules offer superior performance for the test of Fiber Vibration Sensing, DWDM components, AWG , WSS, OPM components, Fiber sensing( especially for vibration fiber sensing application) , optical amplifiers, and other general purpose of fiber optical test and measurement with high wavelength resolution applications.