Reference Standards
See Also: References, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transformers, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
Rubidium Frequency Standard
RFS VXI
-
*RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.
-
Product
Portable Reference Generator - 5VA
RG-5
-
Programmable Frequency & Voltage Portable Sine Wave Generator Sunlight Readlable Display Transformer Isolated Output 360 - 11000 Hz with 1Hz Resolution 1.9V to 125V Output with AGC
-
Product
Standard Emission Monitoring System
CEMS-2000
-
CEMS-2000 is a multi-gas monitoring system aimed to continuously and reliably measure emissions from various industrial combustions. The adoption of the hot-wet extractive method avoids the loss of content during sampling. The system is extendable with additional parameters upon request. All output signals proceed through the data acquisition system and then upload to the DCS or environmental authority server.
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1W1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Standards Waveform Generator
3110A
-
The 3110A software is built around the simple concept of a waveform segment. Each waveform segment can have a unique waveform, (sine, square, triangle, and/or DC offset). Frequency, amplitude and DC offset can be clipped, fixed, variable or swept. Segments can be calibrated (as required in CS101) and set to continue on to the next segment or to hold for an external trigger.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1C
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Reference Cells For PIV-IV Systems
-
NREL calibrated cell used for calibration transfer.The Abet Technologies solar reference cell is a precision instrument for the determination of solar simulator irradiance levels. The sensor is a mono-crystalline silicon solar cell having an area of2x2cm(4cm).The back of the solar cell is attached to the device in such a way that a good heat transfer to the device housing is guaranteed. Below the solar cell a Pt100 RTD temperature sensor is mounted to allow monitoring of device temperature. The device is not shunted allowing the whole IV-curve to be measured. The solar cell is protected by a high quality fused silica window, assuring spectral sensitivity over a 320 -1100 nm range.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-8
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-0
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Pyramid, 3-Sided Chisel 30°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard Connectors
-
C.C.P. Contact Probes Co., LTD.
The Standard Connector Series aims to offer a comprehensive selection of internationallycompatible connectors. Its smart design and simple structure makes it very cost effectiveeven at small volumes.
-
Product
Standard Voltage 50 Pin D-Type Connector Blocks and Breakouts for Pickering
-
The connector blocks and breakouts below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30J
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25A-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-6
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HF-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
15T Standard Running Line Monitor
RLM15T-3.0-S
-
The DLM 15T Running Line Monitor measures the tension on a rope passing through its three wheels. Typically used in cable laying and winch operations to measure and record line tension the robust design has become an industry standard. The monitor can be supplied as a separate item for integration with customers existing PLC’s or with a DLM digital display/HMI touch screen display.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3F
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Disciplined Frequency Standard
2975AR
-
The 2975AR contains a rubidium timebase and provide one 10 MHz, one 5 MHz and one Signal Generator output. The Signal Generator uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50 MHz using front panel controls or from an RS232 serial interface. The 2975AR can be disciplined by a 1pps input signal and provides a 1pps output signal. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
Product
Standard 0.83 (23.50) - 2.85 (80.80) Battery Probe
CCA-004
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 470Overall Length (mm): 11.94
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
Flat, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0F
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard Resistors for Temperature Measurement
-
Measurements International Ltd.
High Stability, Split Guard Circuit, Internal Temperature Sensor, Custom Values Available, Includes Calibration Data.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2E
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64