Thermocouple Calibrators
-
Product
Thermocouple Probes
-
sensor that measures temperature. It consists of two different types of metals, joined together at one end. When the junction of the two metals is heated or cooled, a voltage is created that can be correlated back to the temperature.
-
Product
Thermocouple Bench Selector Switches 6 or 12 Way IEC, ANSI
-
A 6 or 12 way selector in a moulded housing with aluminium front and rear panels. The rear inputs are switched via a front mounted rotary selector switch to the single output socket. Internally wired with thermocouple compensating cable and available with IEC or ANSI thermocouple types K, J, T, N & R/S.
-
Product
Ralston Quick-test™ Microbore Calibration Hoses
-
Ralston Instruments Quick-test™ hoses can be attached and detached without a wrench or thread sealant while maintaining a working pressure of 6900 psi (475 bar). Quick-test hoses are small in diameter, flexible, and low in volume. These hoses provide an ideal way of transmitting pressure during a vacuum or pressure calibration. A wide variety of adaptors provide a connection for most calibration applications.
-
Product
Power Calibrator And Protection Relay Test Set
CP11B
-
Calmet Smart Calibration Devices
Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
Product
K Thermocouple Penetration Probe
TP659
-
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
Product
Hardness Calibration
-
Trescal provides full Hardness Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Hardness Calibration services can be delivered at your site or at our lab. Accreditations for our hardness calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Pressure Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
In any industry, a lot is usually riding on strict pressure settings like the operations, safety systems, etc. Pressure calibrators help in ensuring that the pressure devices are measuring and displaying accurate values. Nagman offers a range of well built, rugged, reliable, easy to use, budget friendly options of pressure calibrators that you can choose from based on your needs.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
mA Loop Calibrators
-
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
Product
Torque Calibration
-
Our years of experience has show us that torque tools given the fact that they are mostly driven by large (and small) springs do tend to drift out of specification quicker than other measurement tools – we have the expertise in house to adjust your tools back into spec and of course provide before and after results.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm
CK520A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Cable Assy 78-Pin D-Type Female to 32 x Mini Thermocouple Plugs
A078DFR-32M002T5A100
Cable Assembly
This 78-pin D-type thermocouple cable assembly is terminated with 32 male mini thermocouple plugs. It is constructed from 7/0.15 (26AWG) silver plated copper wire and screwlocks are provided to secure the D-type to its associated products.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
mA Loop Calibrators
-
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
Product
Acoustic Calibrator
CAL150
-
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
Product
K Thermocouple Penetration Probe
TP657/1
-
“K” Type thermocouple flexible penetration probe. Tolerance according to IEC 60584-2 standard.
-
Product
Gauge Type T Thermocouple Wire
W-TW-20
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
RF Electronic Calibration Module (ECal), DC To 13.5 GHz, 4-ports
N4431D
-
The Keysight N4431D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4431D is a precision 4-ports ECal module that supports multiple selection of connectors like Type-N, 3.5 mm, 7-16 and 4.3-10 connectors and can be mixed up to 13.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Traditional Handheld Refractometer Calibration
104XXVP Series
-
Two-point NIST Traceable Certified Calibration for the following refractometers: 10430VP, 10431VP, 10433VP, and 10440VP.
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Automatic Calibration Module
ACM2506
-
ACM2506 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 6.5 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Electronic Calibration Module (ECal), 50 GHz, 2.4 Mm, 2-port
N4693D
-
The Keysight N4693D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4693D is a precision 2-port ECal module that supports 2.4 mm connectors up to 50 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4693D is included for securing your ECal module and accessories.
-
Product
Manual Pressure Calibration
-
Manual pressure calibrators are a fast and practical solution for generating and adjusting pressure while calibrating analog pressure gauges and other sensors. They are convenient for mobile calibration applications. Fluke Calibration's pressure monitors combine very high accuracy measurement capability and a variety of unique features in compact and easy to use packages, either standalone or integrated with a calibrator. Models include E-DWT DHI electronic deadweight testers; RPM4 DHI pressure monitors and 7050 Ruska pressure monitors.
-
Product
J-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 2 m
745690-J002
Thermocouple Contact (ITA)
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
-
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Pressure Test & Calibration Pumps
-
Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500psi (100bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 918 is an ideal comparison test pump for pressure instruments calibration.
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-K
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
Optical Power Meter W/6 Wavelength Calibrating Spots
-
With six wavelength calibrating spots (980nm, 1310nm, 1490nm, 1550nm, 1590nm and 1610nm), refined design, easy operation, linearity or non-linearity display, SC connector, the MXOPM26-50 hand-held optical power meter can be used for direct optical power measurement as well as relative measurement of optical link loss. It’s an essential test instrument in Optical Communication systems, CATV systems, construction and maintenance applications and more.





























