Thermocouple Calibrators
-
Product
Calibration Services
-
Hirst Magnetic Instruments Ltd
Calibration is essential to keeping our sensitive measuring equipment accurate. We calibrate equipment traceable to National Physical Laboratory (NPL) standards.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Portable Calibration Baths
6109A / 7109A
-
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Manual Pressure Calibration
-
Manual pressure calibrators are a fast and practical solution for generating and adjusting pressure while calibrating analog pressure gauges and other sensors. They are convenient for mobile calibration applications. Fluke Calibration's pressure monitors combine very high accuracy measurement capability and a variety of unique features in compact and easy to use packages, either standalone or integrated with a calibrator. Models include E-DWT DHI electronic deadweight testers; RPM4 DHI pressure monitors and 7050 Ruska pressure monitors.
-
Product
Portable Analyzer and Calibrator
-
ECD’s portable analyzer and calibrator product lines are a simple convenient way to obtain fast, accurate pH and ORP measurements. They provide a milliVolt output signal for fast field analysis of samples, calibration verification, or trouble-shooting of installed sensors.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard COMPACT
-
Rotary Precision Instruments UK Ltd
Designed for horizontal or vertical applications with a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
Calibration Hand Pumps
-
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
Product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
-
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
Product
Humidity Calibration
-
Trescal provides full Humidity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Humidity Calibration services can be delivered at your site or at our lab. Accreditations for our humidity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Economy Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052D
-
The Keysight 85052D economy mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection. Connector gauges may be ordered separately.
-
Product
Vacuum Sensor, Thermocouple Vacuum Gauge for Rough Vacuum
DV-4 Series
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.
-
Product
Cable Assy 78-Pin D-Type Female to 8 x Mini Thermocouple Plugs, 1m
A078DFR-08M002T5A100
-
This 78-pin D-type thermocouple cable assembly is terminated with 8 male mini thermocouple plugs. It is constructed from 7/0.15 (26AWG) silver plated copper wire and screwlocks are provided to secure the D-type to its associated products.
-
Product
Humidity Calibration Cell
-
Humidity calibration involves checking the accuracy of and making the proper adjustment to sensors that measure moisture content in the air.
-
Product
In-Line Speedometer Calibrator Module
-
Hypertech’s In-line Speedometer Calibrator Module is an in-line module to correct the speedometer and odometer for non-stock tire sizes and/or rear gear ratios. This module is perfect for vehicles with computers that don’t allow for tire size and/or rear gear ratio correction or re-calibrate for tire sizes and/or rear gear ratios outside the range of programmers.
-
Product
Isolated Thermocouple Input Module
ADAM-3011
-
1000 VDC, fully isolatedConfigurable thermocouple typeFlexible DIN-rail mountingLinearized thermocouple measurementOperates from a single +24VDCTemperature range of 0 to 50°C
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
-
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
Horizontal Calibration Instruments (Lab)
Labconcept Nano
-
The Labconcept Nano is a new reference in the field of dimensional metrology. It integrates 40 years of knowledge and continuous improvement. It is a remarkable instrument for all measuring tasks that require extremely high accuracy.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Calibration & Demag.
Model 8515-D
-
The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
Calibration Services
-
For over 25 years, OAI (Optical Associate Inc.), is the leader in NIST traceable calibration of instruments for measuring Ultra Violet (UV) light. Originally designed to meet the demanding needs of the semiconductor wafer fabrication industry, OAI developed the most repeatable NIST traceable calibration in the industry.
-
Product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Temperature Calibrator
Model KM-CAL-906
-
Kusam Electrical Industries Limited
This temperature Calibrator gives high accuracy of 0.02% for measure and source. It has dual display, 5 digits for measure and 6 digits for source & white LED for backlight. Volts, RTD & Thermocouple. It gives output up to 500W to 5kW and output for calibrating R, S, K, E, J, T, N, B, L, U type of Thermocouples RTD & Continuity.
-
Product
Class 1 Sound Level Calibrator
HD2020
-
The HD2020 sound level calibrator is a portable, battery operated sound source, suitable for sound level meters (portable and laboratory) and acoustic stations.
-
Product
Robot Calibration
-
Achieve improved absolute robot positioning accuracy via dynamic robot calibration using API’s Laser Tracker and Active Target a self-orienting motorized 360° rotation SMR.
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Calibration Hex Step Adapters
-
When performing torque wrench calibration or testing, adapters are often needed, especially with torque wrenches that have open-end heads. Mountz’s calibration hex step adapter features four common sizes, which will increase the productivity of your torque wrench calibration process. This adapter will make testing and calibration simple and efficient.
-
Product
Process Calibrators
-
AMETEK Sensors, Test & Calibration
Our process calibrators include innovative handheld multifunction calibrators, multi-channel scanners, and handheld loop calibrators and power sources. Our multifunction calibrators feature a new large full color display with an advanced simplicity, easy-to-use interface. The multi-scanner is perfect when there is a need to create traceable documents for sensor calibrations. Calibrate 16 types of RTDs, and 13 types of thermocouples with our handheld calibrators.





























