Product
Ethernet to Modbus RTU Interface
Model 9099
-
* Use Modbus TCP/IP, VXI-11, or Raw Sockets (Telnet) or to control Modbus RTU slave devices.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Interfaces with PLCs or any Modbus TCP/IP Controller.* Fully VXI-11 compliant.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the Modbus network or devices.* 9099 is a 2x to 5x faster than the 8099 and includes a new Modbus device control page.
-
Product
Modbus RTU Rs486/232/422
-
It provides client/server communication between devices connected to different types of buses or networks. Modbus-RTU (Remote Terminal Unit) means that the Modbus protocol is used on top of a serial line with an RS-232, RS-485 or similar physical interface.
-
Product
Ethernet To Modbus RTU Interfaces
-
ICS's Ethernet to Modbus Interfaces provide Modbus TCP/IP to Modbus RTU serial conversion and Raw Socket (Telnet) to control Modbus RTU Slave Devices. Available in small Minibox™ and OEM board formats. OEM board has Ethernet, GPIB and USB interface ports. All Interfaces include the VXI-11 protocol for use with: LINUX, UNIX, SunOS, Apple OS X, HP-UX, IBM-AIX and Windows 2K or later Windows systems.
-
Product
M-6000 Modbus RTU Remote Data Acquisition
-
M-6000 data acquisition remote I/O modules are similar to our I-6000 modules and support both Modbus RTU and DCON protocols. They come in a wide variety of analog and digital configurations. The analog and digital I/O types they support include: current, voltage, thermistor, thermocouple, frequency, relay, strain gauge, etc.
-
Product
TM Series Tiny DCON & Modbus RTU Data Acquisition Modules
-
The tM Series tiny compact modules communicate over Modbus RTU and DCON protocols and provide Analog and Digital I/O functions like isolated digital input, relay and open-collector output. They easily integrate with HMI, SCADA, PLC’s and other systems. They are equipped with two removable terminal block connectors for easy wiring.
-
Product
Modbus Register Converter - Serial To Modbus RTU Interface
-
Translates Modbus registers and variable types from an older Modbus devices to a new Modbus device. The Model 2390 allows upgrading Modbus RTU devices without changing the system software. The 2390 also provides serial control of Modbus RTU devices for new applications that want the ease of using simple ASCII commands strings when controlling Modbus RTU devices.
-
Product
Zigbee Wireless Modbus RTU Data Acquisition
-
ZigBee is a specification based on the IEEE 802.15.4 standard for Wireless Personal Area Networks (WPANs). ZigBee operates in the ISM radio bands and is an inexpensive and self-organizing mesh network for industrial control, embedded sensing, medical data collection, smoke and intruder warning, etc. A ZigBee network consists of a Master, router/repeater and end device. We offer ZigBee converters, repeaters and ZigBee wireless I/O. Our ZigBee data acquisition products come with our FREE EZ Data Logger Software for data logging.
-
Product
M-7000 Modbus RTU Remote Data Acquisition Modules
-
M-7000 data acquisition remote I/O modules are similar to our I-7000 modules and support both Modbus RTU and DCON protocols. They come in a wide variety of analog and digital configurations. The analog and digital I/O types they support include: current, voltage, thermistor, thermocouple, frequency, relay, strain gauge, etc.
-
Product
ANSI X3.28 to Modbus RTU Converter
Model 2399
-
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
Product
Ethernet To Modbus RTU Minibox™ Interface
-
ICS's Model 9099 Ethernet to Modbus RTU Interface is a small Minibox™ Ethernet Modbus Converter that converts Modbus TCP/IP, VXI-11 and Raw Socket to control Modbus RTU Slave Devices. The Model 9099 does not require special drivers and is compatible with the following systems: LINUX, UNIX, SunOS, MAC OS X, HP-UX, IBM-AIX, Windows 2K or later and Modbus capable PLCs. ICS's 9099 uses VXI-11 RPC calls for secure communication with virtually any computer. Easily programmed on a PC by making VISA calls or on a MAC/UNIX/LINUX computer with RPC calls. Special drivers are not required. ICS Electronics is the premier VXI-11 device supplier with 100% VXI-11 compliance in every product. See our extensive Application Notes or download our VXI-11 Tutorial and the VXI-11 Specification for more information about the VXI-11 Standard.
-
Product
4DI/4 Relay Output Modbus RTU Remote I/O
ND-6160
Data Acquisition Module
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
Product
8DI/8DO Modbus RTU Remote I/O
ND-6150
Data Acquisition Module
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
Product
Modbus RTU Analog Input Modules
-
The Datexel range of Modbus RTU analog input cards for both RS485 and RS232 with Modbus or ASCII protocol can be combined with the DAT9000 series of Modbus Masters. A choice of input cards or modules are available and have various optional inputs such as Voltage, Current, Thermocouples, RTD, and Resistance. Also a choice of 2, 4, 8 channel options are available. The DAT3011 is a Modbus RTU Slave with 1 selectable universal input (Thermocouples, RTD, mV, RTD's or Resistance), 2 x 4-20mA or 0-10V input and 2 x4-20mA outputs. The DAT3011 also has 3 digital inputs and 3 relay outputs. Each module is isolated from each other and is set up using the DAT3000 software Development package which is free of charge from the Datexel download web page. Datexel also has universal input modules. An 8 channel analog input card is available making the DAT3000 series a very economical solution to large and small scale Data Acquisition. Combining these analog input cards with the analog output cards, the digital input/output cards and the communication devices make Datexel the smart choice where Data Acquisition is required.
-
Product
RS232 RS485 RS422 Serial To Ethernet Modbus Converters / Device Servers
-
In the past two decades, legacy serial communication protocols such as Modbus have merged rapidly with modern TCP/IP communication, yielding benefits including widely available infrastructures and greater distance, reliability, and flexibility. CommFront offers a range of industry-proven, easy-to-use serial to Ethernet converters and device servers, both hardware and software types. The applications of our serial to Ethernet converters include acting as a device server or a Modbus RTU/ASCII to Modbus TCP protocol converter; extending serial ( RS232 / RS485 / RS422 / TTL) communication distance over Ethernet network; controlling serial devices from remote Modbus TCP software or Modbus RTU master via Ethernet network; making a wide variety of M2M communication applications possible by enabling client access independent of any operating system or proprietary protocol; and converting conventional serial data network into TCP/IP network, etc.
-
Product
4 Digit Temperature Meter (5 Channels)
CM1-TX5
-
RS-485 Modbus RTU protocol (with communication LED indicator)RS-485 address 1~255Communication Baudrate 9600, 19200, 38400, 57600, 115.2KParity check N81, N82, E81, O81Input 5 channels of signal selectable:thermocouple/PT100.5 channels of input can be set to play 1~10 seconds loop display.1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself.5 channels of input signals with LED unit cycle display.Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system.Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoringCan be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel
-
Product
Temperature & Humidity Transmitter
HTO
-
- CO2 measuring element: NDIR Sensor 2- CO measuring element: Electrochemical sensor- Temperature/Humidity sensing element : CMOS sensor- Analog output option:4~20mA or 0~10V- Communication output option:RS485 Modbus RTU- Configured by PC with free software via USB cable (option)- Present value offset adjustable- Inside buttons for adjust output parameters- LCD backlight color to Indicated CO/CO concentration 2- Temperature measuring range can be -50~100℃ via USB console port to setting
-
Product
10 Digit Rate/Batch Counter (Pulse)
CS2-TM-Pulse
-
The CS2-TM(Pulse Input) is innovation totalizer.Adtek builds in high technology with wide input range from 0.01Hz~ 140.00KHz with auto-range function at same unit. There are three setting modes for K factor, 1/K factor and flow speed to match the difference output description of flow-meters.The Totalizer provides high accuracy measurement, display, control and communication (Modbus RTU mode) of Pulse from Flowmeter or encoder, proximity switch, photo switch for length control.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.
-
Product
M-2000 Modbus RTU Remote Data Acquisition Modules
-
M-2000 data acquisition remote I/O modules are similar to our I-2000 modules and support both Modbus RTU and DCON protocols. They come in a wide variety of analog and digital configurations. The analog and digital I/O types they support include: current, voltage, thermistor, thermocouple, frequency, relay, strain gauge, etc.
-
Product
Gas Detection System Controller
SMC Sentry IT
-
The SMC Sentry IT Controller is a powerful network-enabled hazardous gas detection system that operates up to 32 detectors and interfaces with devices over Modbus RTU, 4-20 mA, Sentry PSG Bus, and conventional dry contact. The embedded web application enables users to view important data remotely and provides connectivity into the Industrial Internet of Things (IIoT).
-
Product
Load Cell Transmitter
MODEL SST-HV
-
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
Product
Master And Slave
Smart I/O
-
An I/O server is a software which controls and monitors one or more PLCs /RTU's using various communication protocols.Our I/O servers are built on highly optimized Windows 32bit platform. They are capable of handling very large scale SCADA systems with minimal impact on CPU usage, resulting in effective timing and usage of available hardware.Currently, we have Master and Slave solutions for DNP3 and Modbus (ASCII, RTU, TCP). Please select the appropriate tab above for more informaiton.If you are looking for a specific I/O Server, please contact us with your needs.
-
Product
M-7000 Modbus RTU Remote Data Acquisition Modules
-
M-7000 data acquisition remote I/O modules are similar to our I-7000 modules and support both Modbus RTU and DCON protocols. They come in a wide variety of analog and digital configurations. The analog and digital I/O types they support include: current, voltage, thermistor, thermocouple, frequency, relay, strain gauge, etc.
-
Product
Digital Panel Meter
VAM
-
VAM Voltage & Current Meter has been designed with high accuracy dual channels(isolated) measurement, dual display and communication of 0~600V and 0~10A for DC/AC/TMRS. In compact size(48 x 96mm)● Build in mathematic function such as Addition / Subtraction / Multiplication / Division / high or low selector in 2 channels input to meet various testing equipment inquiry.They are also build in 4 Relay outputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.
-
Product
ANSI X3.28 To Modbus RTU - Serial To Modbus RTU Converter
-
Designed for legacy systems where there is a need to replace older X3.28 protocol Controllers and with new Modbus RTU Controllers. The Model 2399 provides ANSI X3.28 to Modbus RTU Conversion without changing the existing system software. The 2399 also provides serial control of Modbus RTU devices for new applications that want the ease of using simple ASCII commands when controlling Modbus RTU devices.
-
Product
Modbus-RTU I/O Modules
-
Sophisticated watchdog timer functions allow the application to define the module's failsafe output state. The watchdog timer invokes the failsafe condition when communication between the host and module exceed a duration specified by the application. For further security, a second hardware watchdog timer monitors the microcontroller for failed operations or a "lock-up" condition and automaticaly resets the unit.
-
Product
Digital Panel Meter
CM3-VA9
-
CM3-VA9 is a multifunctional 3-phase voltage/ current meter.With 3 phase voltage or current display at the same, configurable display range via front buttons, anti-inference design, reliable quality and easy to use and install, CM3-VA9 also has multiple I/O functions including 6relay outputs, 3 analogue output and a RS485 communication port running the Modbus RTU Protocol
-
Product
Networked Absolute Inclinometer
T7
-
The T7 is available in several interface and protocol options. The physical interface can be RS232, RS485 or US Digital's CAN (Controller Area Network). The protocol can be either US Digital's serial protocol or Modbus RTU. The RS232 version supports a single T7 with up to 100 ft of cable. For users that need longer cable lengths or multiple T7s on a single bus, the RS485 or US Digital CAN (Controller Area Network) version can be used. The USD-CAN protocol allows a network of up to sixty-four T7s to be connected to a single host. Power for each T7 is supplied over the CAN network cable. The host accesses the USD-CAN T7s through US Digital's low cost CANA-232/CANA-485 adapter module. This module allows the host to access each T7 on the network using simple, easy serial port commands, just like the RS232 version. The RS485 version supports up to 32 T7s on the bus.
-
Product
1-Port Isolated RS-232/422/485 Communication EtherCAT Slice IO Module
AMAX-5090
-
Versatile Communication: The AMAX-5090 supports RS-232, RS-422, and RS-485 communication, making it adaptable to various industrial applicationsSeamless Data Transfer: With TxD and RxD channels and full/half-duplex capabilities, it ensures smooth and reliable data transmissionEffortless Integration: Interfaces for UART and Modbus RTU to EtherCAT simplify integration into existing systemsRobust Performance: Featuring a 1,000-byte receive and transmit buffer and a wide range of baud rates (1,200 to 115,200 bps), it guarantees efficient and high-speed data processingRugged and Reliable: Built for demanding environments, it operates in temperatures ranging from -25°C to 60°C and is compliant with RoHS standards
-
Product
Flow Monitor
B2900
-
Blancett B2900 flow monitor offers advanced digital signal processing technology in an easy-to-access package. Enclosed in a spacious polycarbonate NEMA 4X housing, the electronics are located on a single board, designed for straightforward and convenient field installation. The B2900 enclosure features an LCD display with push button programming as well as a pre-drilled hole for external wiring connections, such as Modbus RTU and other outputs.
-
Product
8-Slot Distributed DA&C System For RS-485
ADAM-5000E
-
RS-485 communication for easy installation and networking8 slots for up to 128 points data monitoring card control in one moduleSupports ADAM ASCII protocol or Modbus®/RTU protocolSupports Modbus/RTU protocol with user-defined Modbus addressExtensive software support, includes windows DLL drivers, OCX drivers, OPC server and popular HMI/SCADA software driversSeamlessly integrated with easy-to-use ADAMView data acquisition software