Standard Transformers
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Standard 2.40 (68.00) - 6.20 (176.00) Battery Probe
BIP-8
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 188Test Center (mm): 4.78Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 60Recommended Travel (mm): 1.52Overall Length (mil): 396Overall Length (mm): 10.06
-
Product
Standardize Production Test Software For PCBAs And Electronic Devices
test
The vast majority of test project man-hours are spent on software development, so the choices that teams make in software tools and architecture have significant impact on deployment schedules. Standardizing software across a team or organization increases both efficiency and proficiency, lowering the risk of missed deadlines and improving test quality and reliability. Test software must:
-
Product
Standard Products
-
DLM’s standard product range is designed by experienced in-house design engineers and manufactured at our workshop in the UK by qualified technicians.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-FK180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
ANSI Standard Burden Sets
Voltage and Current
-
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
Product
Standard - 6.00 (170.00) - 14.00 (397.00) Feed Through Probe
P2447-1W
-
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 225Test Center (mm): 5.72Full Travel (mil): 300Full Travel (mm): 7.62Recommended Travel (mil): 200Recommended Travel (mm): 5.08Overall Length (mil): 1,145Overall Length (mm): 29.08
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5E
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Multiparameter CTD with a Wide Choice of Standard Sensors.
MIDAS CTD+
-
Featuring Valeport’s latest 400 Series electronics, the CTD+ will sample all fitted sensors at exactly the same instant, at up to 8Hz. Advanced setup software allows a variety of sampling regimes including burst modes, delay starts and conditional sampling. Available with up to 64Mbyte memory and internal battery pack, as well as a selection of real-time output formats, the CTD+ may be used with Valeport’s own water bottle carousel.
-
Product
PPS Clamp Transformer
-
PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
AC Test Transformer
-
Yangzhou Power Electric Co., Ltd
The AC test transformer are especially designed for testing high voltage products and components, such as cables, power transformers, gas-insulated switchgears, bushings and arresters. It is also suitable to test insulation materials. They are used to generate testing high voltage and function as part of the complete system. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
A Global Standard for Acoustic Absorption Measurements
Alpha Cabin
-
The Alpha Cabin has been especially designed for the measurement of acoustic absorption properties of materials and components used for the noise insulation of vehicles. The Alpha Cabin is significantly smaller than normal reverberation rooms and therefore ideally suited to use within limited space capacities. The acoustic absorption of the Alpha Cabin itself is also very low: Thanks to the high level of sound insulation, background noise in the frequency range of interest is kept to a minimum.
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4B
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Multi-Element Standards
-
These multi-element standards consist of multi-layer thin film coatings, one on top of the other, upto a maximum of 6 elemental coatings. It is generally recommended to have coating thicknesses < 20 µg/cm2, so as to cause negligible notable matrix effects, in particular absorption of X-rays emitted in lower deposits by those covering them.
-
Product
Precision Multirange Current Transformer
P-2000
-
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
Product
Cold-Atom Frequency Standard
-
Rack-mount microwave atomic clock using laser-cooled 87Rb atoms. Production unit target specifications: Allan deviation 2×10-12 @ 1 s, 2×10-14 @ 104 s; flicker floor 1×10-14; absolute accuracy < 1×10-13.
-
Product
Current Transformer
-
OutputDC 10VLinearityAs graph aboveApplied VoltageAC 2000V, 1min (between aperture and terminals)ImpendanceDC 500V, over 100M (between aperture and terminals)Fire Retardant Level94V0Output Terminals2.54 mm pinAnti-vibration50 Hz 5G
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2H
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
200KHz AUTOMATIC TRANSFORMER TEST SYSTEM
VE2729XAU
-
Its a Microprocessor Based 200KHz Automatic Transformer Tester with inbuilt 20 Pin Channel Scanner for Automatic Switching and Testing Coils & Transformers (Ferrite) with Max. 20 PINS. Test Parameters : -> Inductance (L)-> Leakage Inductance (Lk)-> Capacitance (C)-> DC Resistance (Rdc)-> AC Resistance (Rac)-> Turns Ratio with Winding Polaity-> Quality Factor (Q)-> Impedance (Z)
-
Product
Transformer Oil Gas Analysis
-
It is necessary to analyze outgas in transformer insulation oil in power plant facilities. Shimadzu offers a System GC compliant with ASTM D 3612 Method B (oil stripper sampling) or ASTM D 3612 Method C (headspace sampling). The Nexis GC-2030TOGAS3 system, equipped with a PDHID, enables the analysis of more trace amounts of permanent gas than conventional systems.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4A
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4E
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53