Transformer Comparators
-
product
Transformer Winding Resistance Meter
10A
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Automatic Instrument Transformer Test Set
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
product
200KHz AUTOMATIC TRANSFORMER TEST SYSTEM
VE2729XAU
Its a Microprocessor Based 200KHz Automatic Transformer Tester with inbuilt 20 Pin Channel Scanner for Automatic Switching and Testing Coils & Transformers (Ferrite) with Max. 20 PINS. Test Parameters : -> Inductance (L)-> Leakage Inductance (Lk)-> Capacitance (C)-> DC Resistance (Rdc)-> AC Resistance (Rac)-> Turns Ratio with Winding Polaity-> Quality Factor (Q)-> Impedance (Z)
-
product
Variable Transformer DC Power Supplies
Variable DC power supplies are AC to DC power supplies with a variable DC output. The output can be varied with a Variable Transformer (also known as variac). The Variable Transformer can be adjusted manually or with a motorized control. The AC input power can be single phase or three phases. With single phase AC input, the DC output ripple is very high (50%). With three phase AC input, the DC output ripple is low (5%). This would be a key benefit for selecting three phase AC input instead of single phase.
-
product
Loss Measuring System for Transformers
LiMOS
HIGHVOLT Prüftechnik Dresden GmbH
The transformer loss measuring system LiMOS is designed for highly accurate measurement of losses and other parameters required in the framework of routine and type testing of power transformers. The combined voltage/current sensors and the digital signal processing enable a very compact design with only one HV device per phase with smallest volume and footprint. The digitized and preprocessed signals are transmitted via fiber optic cable to the receiver unit (LiMO-MCSU).
-
product
Transformer Ratio Meter
TRM 1000
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
product
Filament Transformers
Osborne designs and produces high impedance and unregulated Filament Transformers. An unregulated filament transformer supplies a specified voltage and current to the filament of an electron vacuum tube. High impedance filament transformers are designed around a tungsten tube filament. Osborne often works with our clients to increase the life-span of their vacuum tubes through the use of a regulated voltage supply.
-
product
Current Transformers
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
product
Transformer Degaussing Analyzer
KRI6691
The KRI6691 transformer degaussing analyzer injects current into the test winding by applying ±90V voltage, and collects the terminal voltage and winding current to draw the hysteresis characteristic curve. Linear quantitative analysis of transformer remanence can be performed, and rapid demagnetization can be achieved by tracking the hysteresis curve.
-
product
Transformer Test Equipment
A range of equipment dedicated to the testing of transformers of all types and sizes.
-
product
Transformer Ratio Meters / TRM-11
TRM-11
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fully automatic: No manual balancing. Automatic measure transformer group. Automatic calculation of ratio error.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Auxiliary Current Transformers
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
product
Transformer Winding Resistance Meters
TWA Advanced Series
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
product
Split type AC Current Transformer
CTS-400
MULTI MEASURING INSTRUMENTS Co., Ltd.
*5A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy to install by metal fitting.
-
product
Transformer Oil BDV Tester (Single Cup)
HTJY-80B / 288
Wuhan Huatian Electric Power Automation Co., Ltd.
The tester is designed to test the power strength of all kinds of insulating oil.
-
product
Auxiliary Potential Transformers
Osborne Auxiliary Potential Transformers (Aux PT’s) are used in utility and commercial industrial power systems. Osborne works with our clients to identify the safety advantages of using auxiliary potential transformers (Aux PT’s) to establish protection schemes for high voltage equipment. Aux PT’s step the voltage down to safer levels, normally below 600 V AC.
-
product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.
-
product
PPS Clamp Transformer
PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.
-
product
Linear Variable Differential Transformers (LVDTs)
Whilst there are several ways to measure displacement, the Linear Variable Differential Transformer (LVDT) remains a popular transducer in most industrial applications. LVDTs initially were used as a means of taking dimensional readings in laboratories. They gained popularity in a wide variety of industrial monitoring and control applications, and whilst an LVDT is used to measure displacement the technology can be employed within other transducer types.
-
product
32 Channel Analog Comparator Module
DP-VXI-5106
DP-VXI-5106, is a 32 Channel Analog Comparator Module with 32 channels of differential analog window comparators. Each channel is provided with a window comparator as well as a Level Comparator , software selectable on an independent channel basis. All the 32 channels have been grouped into four groups of 8 channels each. This allows the user to configure the comparator module based on the application to initiate alarm action to exactly meet application requirements. Each Comparator channel can be programmed to generate a VXI bus interrupt or can be masked through software. An Interrupt is generated on an individual channel basis or on a group basis. Front panel outputs of buffered TTL and a 2-CO relay contact is available for every group (4 outputs total each). Also, a common buffered TTL interrupt output and a common 2-CO relay contact is also available at the facia providing extensive flexibility in application engineering.This module is an ideal device for GO / NO-GO testing in Test Stand Automation where important signals must be continuously monitored for system shut down purposes and safety inter-lock implementation. The hardware implementation in the Comparator module provides high-speed throughput and reliable inter-lock implementation. The interrupt out signal can be further wired as trigger signals for pre and post trigger analysis of signal data for post acquisition detailing.Each channel provides a Window Comparator implementation and a Level Comparator implementation. The configuration is programmable through software and the alarm can be generated if the signal is within the window or outside the window. Similarly, a high and low limit can be set and a trigger is generated if the signal exceeds the high limit or drops below the low limit.
-
product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Transformer Rated Pre-Wired Meter Enclosures
TESCO Transformer-Rated Pre-Wired Meter Enclosures are built with the TESCO tradition of quality and durability. TESCO enclosures are designed for use in commercial and industrial metering installations where voltage ratings of 480 and above are required. The enclosures are available with ringless, single piece or two piece covers and can be pre-wired between the test switch and socket to meet your exact specifications.
-
product
Digital Gauge Counter with Comparator Function
DG-4320/4340
The DG-4320/4340 Digital gauge counters display and calculate the measured values from linear gauge sensors.In addition to four basic functions (Multiplication switching, factor setting, offset setting and number of decimal place setting), new features such as calculation display function and condition memory function are equipped. It helps in-line measurement to work at production site efficiently.
-
product
Transformer Calibrator
HTQA-C / 345
Wuhan Huatian Electric Power Automation Co., Ltd.
A device used to change the current.
-
product
Split-Core Current Transformers
CTS Series
Continental Control Systems LLC
The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit. 0.333 Vac output at rated current Accuracy ±1% from 10% to 100% of rated current Phase angle <2° degrees at 50% of rated current (valid for 70 A or higher) 8 ft. twisted-pair wire, 600 Vac rated UL recognized for voltages up to 600 Vac, CE mark, RoHS
-
product
Transformer Testing Equipment
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).