Showing results: 2551 - 2555 of 2555 items found.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TT Series - IBEKO Power AB

    RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Power Phase Converter Single phase 220VAC to 3 phase 380VAC Converter

    SDT-40KW - Zhejiang Sandi Electric Co., Ltd

    SANDI SDT series single-phase to three-phase converter, adopted SVPWM modulation control technology, which can convert ordinary single-phase power to industrial three-phase power. After through SDT series single-phase to three phase converter power conversion, the three-phase power output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards of three-phase power quality, applicable to all types of load.The SDT series single-phase to three-phase converter can solve production inconvenience because of some areas with the three-phase electric power restrictions, also solved some user requirements that can?謒?apply for the three-phase electric because of space limitation.Features1) Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It's service life can up to 15 years or more.2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter?謒?usage, which reduced the cost of equipment investment, easy to connect wires and control.3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage.4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference.5) Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load.7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices.8) Output perfect protection function, with output over-voltage, overload, short circuit, over temperature, self-diagnosis protection and other protection.9) High conversion efficiency, high instantaneous power and low load loss.10) The input voltage, output voltage, frequency and phase can be custom made.SpecificationModel SDT-40KWIsolation mode Low Frequency TransformerAC InputRated voltage (Vac) 240V single-phase 60HZVoltage range (Vac) 190-270VInput current (A) 167AAC OutputRated power (KW) 40KWRated voltage 240V ± 2%Output phases Three-phase with Neutral wires (L1, L2, L3 + N)Rated current (A) 96AOutput frequency 60Hz ±0.05 (50HZ can be set)Waveform Pure sine waveVoltage accuracy Load balancing≤1%、Unbalanced load≤5%Waveform distortion rate (THD) Linear load≤2%、Nonlinear load≤3%Dynamic Response 5%,≤50ms (load 0~100%)Power Factor (PF) 0.99Inverter Efficiency ≧85%Electrical insulation properties 2000Vac、1 MinuteProtection FunctionOverload Ability 150%、10sProtection Input under voltage, overvoltage, output over-current, short circuit, overheating etc.Display LCD+LEDMethod of working Working continuouslyCooling method Intelligent fan coolingShort-circuit protection No automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protection IP20 (indoor)Working Altitude(m) ≤3000mWorking temperature (℃) -20~+50℃Relative humidity (℃) -25~+85℃Noise (1 meter) ≤60dBReference size: (W x D x H) 750×750×1480mmReference net weight (Kg) 340Kg

  • ARINC818 Cards

    AIM GmbH

    > ARINC818 is a specification which has become an Industry standard for the transmission of uncompressed digital video. This commercial standard uses Fibre Channel as a point-to-point communication link for low latency with the ARINC818 defining the packetized protocol for transmission of the digital video information. It is highly flexible and can be used for a variety of onboard display systems in both commercial and military applications. AIM’s ARINC818 cards use our field proven Common Core hardware design giving the best performance, best feature set and highest functional integration on the market. The use of SoC (System on Chip) based core designs with one dual core RISC processor per port, massive DDR3 memory and IRIG-B time encoder/decoder functions are standard. The ARINC818 modules are available in PCIe formats.The new ultra high performance intelligent 4-lane PCIe 2.0 interface modules offer 2 ports with full function test, simulation, monitoring and analyzer functions for ARINC818 interfaces. The dual core processor provides onboard processing and data transfer capabilities for the most demanding applications including ARINC818 support done on board level. Large and high data throughput DDR3 RAM is accessible for the onboard processor as is a high performance FPGA implementing the customized ARINC818 Interfaces enabling the board to analyze incoming data in real time. Each module provides 2 ARINC818 compliant ports. SFP cages make it suitable for different media types as optical or electrical network technologies. Each module is delivered with a Board Support Package (BSP) containing the onboard driver software, a full Application Programming Interface (API) and detailed getting started and programming guides. Powerful PBA.pro databus test and analysis software is optionally available for all our ARINC818 cards.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options