product
Surge Generator
SG61000-5
Automatic lightning surge generator (or Lightning surge immunity) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
-
product
Power Systems Recorder
TESLA 2000
ERLPhase Power Technologies Ltd
TESLA 4000 is an easy-to-use and cost effective, state-of-the-art, multi-time frame (simultaneous) power system monitoring recorder. Its integrated Phasor Measurement Unit (PMU) functionality streams synchrophasor data for wide area monitoring. Enabled with IEC 61850 protocol, TESLA has advanced communication capabilities that, together with its powerful recording features, provide the most versatile and complete monitoring of power system health.
-
product
Close Match Solar Simulators
We design and manufacture a wide range of world leading solar simulators that meet and surpass the IEC, ASTM and JIS international standards. Our close spectral match solar simulators are used across the globe in world-leading laboratories. Our award winning Unisim solar simulators are used in both research and development work as well as 24/7 production facilities and are regularly cited in the latest photovoltaic research literature.
-
product
Regenerative AC Emulator, 1200 VAC, 65 A, 90 KVA, 3‑Phase
SL1213A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Medical Computer Equipped With MXM Graphics Module Supporting NVIDIA Quadro® GPU With 8th/9th Generation Intel® Core™ I7/i5/i3 In LGA1151 Socket. Compliant With IEC 60601-1/IEC 60601-1-2
MLB-3002
- 2x PCIe Gen3 x4 expansion slot for Full Height Half Length add on card, each slot is 25W power budget and additional Molex 4 pin power cable (12V/1.5A and 5V/2A) support- ADLINK MXM Graphics module support (Type A/B, up to 120W)- 8th/9th Gen Intel® Core™ i7/i5/i3, Celeron® processor- Dual SODIMMs for up to 64GB DDR4 non-ECC memory (dependent on CPU)- DisplayPort (2 from CPU, 4 from MXM)- 1x M.2 E key supporting 1630 or 2230 for Wi-Fi/Bluetooth module, 1x M.2 B key supporting 2242 or 2280 for SATA storage module- Reliable Molex type 12V DC-in connector- 1x Intel® i219-LM and 3x Intel® i210-AT
-
product
Datalogging Digital Sound Level Meter with RS-232 Software and Cable
735
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 735 Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
product
ACP Portable Electrical Current Transformer Test,CT/PT Analyzer
Chongqing Assen Power Equipment Co., Ltd
ACP portable Current transformer analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
-
product
Voltage Dips and Interruptions Generator
CSS61000-11
The voltage dip and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point, CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have more fine performance such as high reliability, convenient operation, and full meet the standard requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11
-
product
Module Breakage Tester
MBT
The tester is used to provide confidence that the risk of physical injuries can be minimized if the PV module is broken in its specified installation. The module breakage test is specified in the IEC 61730 (MST 32).
-
product
Solar PV Test Equipment
The Seaward Solar range of electrical solar PV test equipment enables Photovoltaic installers to meet all testing and certification requirements of IEC 62446 safely and efficiently.
-
product
GNG-* “Go” and “Not go”gauge
GNG-*
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
product
Protection Relay Testing
Haomai Electric Power Automation Co.,Ltd.
1)Embedded industrial PC with 9.7" TFT LCD screen 2)Both online and offline test available 3)Can test both universal and IEC 61850 protection relay 4)6-phase current + 6-phase voltage output 5)Provide various type of messages which conforms to IEC 61850-9-1/9-2,GOOSE, IEC 60044-7/8 FT3 6)Able to test MU and optical digital signal 7)Built-in GPS module
-
product
Leakage Current Tester
TOS3200
The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment.It enables you to conduct tests that conform to the requirements of the applicable IEC, UL, JIS, and other standards, as well as the Electrical Appliance and Material Safety Law. The memory in the main unit stores the 51 types of test conditions laid down in the IEC/JIS standards for information technology equipment, household electrical appliances, audio, video electronic apparatus, luminaires, motor-operated electric tools, and electrical equipment for measurement and control and in the Electrical Appliance and Material Safety Law, thereby enabling you to conduct standard tests with simple panel operation.
-
product
Transformer Test Equipment
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
product
Fluorescent Lamp Asymmetric Pulse Tester
UI2002C
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
product
Heat Cycling System
Yangzhou Power Electric Co., Ltd
High current test systems are used to test the thermal stability of equipment and components. The test system induces a current in the test object causing it to heat up.The system can perform the heat cycle testing for power cables type test and pre-qualification test according to IEC 60840, and IEC 62067 etc. Based on pre-qualification test needs, test system is divided into two parts: test sample loop and simulation temperature loop.
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 30 KVA, 3‑Phase
SL1201A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
product
Reach-In Solar Panel Test Chamber
For testing various size solar panels WIEBER designs and manufactures Solar Panel Test Chamber. The test are to be performed according to various standards of ASTM, IEC, UC etc. Solar panels need to pass environmental tests as per IEC and other standards requirements to prove their long term performance and resistance to temperature and humidity extremes. Solor Chamber also known as Solar Photovoltaic Testing Chamber and PV Module Test Chamber.
-
product
Battery Capacity Testers|Discharge Testers
DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.
-
product
Optoelectronic Sensors
BERNSTEIN optoelectronic sensors can be divided into three basic types: * Through-beam, * Retro-reflective, and * Diffuse reflective. The specifications of the above mentioned sensors are defined in the standard IEC 60947-5-2 and are in conformity with the CE.
-
product
Transformer Ratio Meters
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
product
Burst-Generator
SFT 1420
The test generator SFT 1420 simulates quick transient noise interference as they are defined in the standard IEC / EN 61000-4-4. The single pulses show a very short rise-time (5 ns) and due to this a wide RF-spectrum up to 300 MHz. RF interferences are the result.
-
product
Digital Insulation Mult-Meter
8010 IN
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1
-
product
Annual testing of Automatic Identification System
AIS
The purpose of an annual testing is to determine that AIS is operational as defined in appropriate performance standards - the International Maritime Organization (IMO) Performance Standard (MSC 74(69)) and IEC standard, IEC 61993-2: Maritime Navigation and Radio Communications Equipment and Standards Automatic Identification Systems (AIS).
-
product
Innovative Open Standard
PROFINET
PROFINET is the innovative open standard for Industrial Ethernet, development by Siemens and the Profibus User Organization (PNO). With PROFINET, solutions can be implemented for factory and process automation, for safety applications, and for the entire range of drive technology right up to clock-synchronized motion control. PROFINET is standardized in IEC 61158 and IEC 61784. Profinet products are certified by the PNO user organization, guaranteeing worldwide compatibility.
-
product
HardFiber System
IEC 61850
The HardFiber System is a KEMA tested IEC 61850 Process Bus Solution that allows the mapping of measurements made in the switchyard to protection relays located in the control house using secure communications. The HardFiber System addresses the key technical and logistic challenges affecting the labor required for substation design, construction and maintenance.
-
product
Circuit Breaker Test Equipment
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.
-
product
Capacitor Contactor
KML
Lifasa - International Capacitors, SA
The new KML contactors are designed in accordance with IEC 60947-1 and are suitable for the connection of three-phase power capacitors. Thanks to its pre-load block mounted on the same contactor, the strong current tips produced at the moment of capacitor connection are reduced and the contactor itself is protected at the same time.