product
Hardy Shaker
HI-913
This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.
-
product
Sound Power Reference Source
Qref
Precision omni-directionallity in all directions, horizontal and vertical plane. This source has a frequency range of application between 100 and 8000 Hz (third octave bands) Despite only weighing 1.4 kg and having a diameter of 105 mm, it produces a maximum sound power level of Lw 104 dB.
-
product
Coherent Modulation Transmitter
IQTX
Generating and controlling phase modulated optical signals is easy with the IQTX. The IQTX is referred to as a ‘Golden’ reference optical signal source because of its high repeatability and reliability.Its high bandwidth of 40 GHz ensures high quality optical signal generation, making it the ideal optical signal source for coherent communications applications.
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
product
RF Calibration Accessories
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
product
Reference Frequency Generator
MFCh
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
product
Signal Analyzer
Choose from an extensive selection of signal analyzer products from DC to 44.5 GHz and extendable to 325 GHz.With excellent total level accuracy, dynamic range and performance, Anritsu spectrum/signal analyzers not only can capture wideband signals but FFT technology supports multifunction signal analyses in both the time and frequency domains. Moreover, the built-in signal generators on some models outputs both continuous wave (CW) and modulated signals for use as a reference signal source.
-
product
IRIG Timecode Receiver and Generator
RG1
The RG1 Time Code receiver synchronizes to IRIG-A/B/G time codes and provides precise time in a memory register, for the host SBC.The IRIG output of the card can be used to synchronize other IRIG time code readers. Additionally, the RG1 includes a real-time clock (RTC) that may be used as a reference source for IRIG master applications, to free the system processor from the task of updating the master timer.
-
product
CN-37 Blackbody
Compact thermal camera reference source. Compatible with all thermography cameras on the market and IEC 80601-2-59 compliant. Available now, ready to ship.
-
product
Blackbody System
IR-508/301
Infrared Systems Development Corp.
The IR-508 blackbody reference source is designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 0.25" cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allows users to calibrate, align, and measure infrared devices and phenomena of all types.
-
product
Conventional Panel-mounted Type Power Amplifier Control Unit
PAT01
PAT01 is a power amplifier control unit that controls timing output and reference signal test source for power amplifier.
-
product
4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function PXI modules
PXI-2500 Series
ADLINIK PXI-2501 and PXI-2502 are high-speed, high-performance analog output multifunction PXI modules. These devices are able to update up to 8-CH, 12-bit analog outputs imultaneously sustaining 1 MS/s. The reference sources and output polarities are programmable individually per channel. Combine this with the multiplying PXI architecture, ADLINK PXI-2500 series PXI modules can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory. The PXI-2500 series integrate up to 8-CH, 400 kS/s, 14-bit single-ended analog inputs with programmable polarity, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timer/counters.
-
product
Mini Light Source Meter
MLS-100
•Stabilized Light Source•1310nm & 1550nm•Very small and lightweight•Controlled by Smartphone or PC via USB or Bluetooth•Smartphone application software and PC software•Li-ion Polymer Rechargeable battery•Battery charging via a USB interface•Universal 2.5mm adapter to accept FC, SC or ST•Reference light source for optical test
-
product
NI-6581B, 100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO
783887-01
100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO—The NI-6581B is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. A digital I/O adapter module for FlexRIO can be used to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581B can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.
-
product
2 Channels, 28-115 Vrms, 47 Hz-2.5 kHz (max. range) programmable
AC3
The module is used to provide an AC signal source when a secondary reference source other than the optional on-board reference module is required. The modules are programmable for full range voltage outputs from 2 to 115 VAC, and frequency from 47 Hz to 10 kHz.
-
product
Receiver-Synchronizer
VCH-311C
The receiver-synchronizer VCH-311C is intended for use in synchronization networks as a primary reference source of highly stable synchronization signals of the first level of the hierarchy, periodically corrected in frequency according to the exact time signals (time scale) of the NKA KNS GLNASS / GPS
-
product
Emissions Reference Source
ERS
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
product
RF Reference Source
96040A Series
The 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.
-
product
4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function PXI modules
PXI-2502
ADLINIK PXI-2501 and PXI-2502 are high-speed, high-performance analog output multifunction PXI modules. These devices are able to update up to 8-CH, 12-bit analog outputs imultaneously sustaining 1 MS/s. The reference sources and output polarities are programmable individually per channel. Combine this with the multiplying PXI architecture, ADLINK PXI-2500 series PXI modules can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory. The PXI-2500 series integrate up to 8-CH, 400 kS/s, 14-bit single-ended analog inputs with programmable polarity, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timer/counters.
-
product
Comb Generator
CG118
The main application of comb generator is to quickly verify 1GHz above radiated emission and conducted emission test setup.And the most important application is 3m chamber and 10m chamber 1GHz above to18GHz with 250MHz frequency spacing for site validation,shielding efficiency. reference signal source Noise Generators Signal Generators
-
product
Reference Sources
A physical or digital document that you would refer to for more information about a topic.
-
product
20 Bit Dual-Channel Reference Source
DRS20
The DRS20 is a dual-channel reference source offering ultra high precision and stability and provides a +/-10 V output. The output current can be up to 10 mA and the 4 wire connection provides a 1 µV/mA load regulation. The high precision and stability is achieved by using a temperature controlled voltage reference.
-
product
2 Channels, 2-28 Vrms, 47 Hz-20 kHz (max. range), programmable
AC2
The module is used to provide an AC signal source when a secondary reference source other than the optional on-board reference module is required. The modules are programmable for full range voltage outputs from 2 to 115 VAC, and frequency from 47 Hz to 10 kHz.
-
product
Timing And Sync
Precision timing is critical for defense and commercial industries and powering essential network operations. Safran offers secure time servers and solutions for accurate network synchronization, ensuring security, compliance, and adherence to best practices. Safran excels in delivering precision timing solutions, including NTPNTP, or Network Time Protocol, is a widely used networking protocol that enables computers and devices to synchronize their system clocks with a reference time source. It ensures accurate timekeeping in computer networks by allowing devices to obtain precise time information from NTP servers, which are typically synchronized to highly accurate atomic clocks. NTP is essential for various applications and services that rely on synchronized time, such as network security, authentication, and data logging. time server appliances and GPSGlobal Positioning System is a navigation satellite system. See also master clocks globally.
-
product
Signal Conditioners
General Purpose
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
product
High Accuracy AC Reference Source
515
Clarke-Hess Communications Research
The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.
-
product
4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function DAQ PCI Express Cards
DAQe-2500 Series
ADLINK DAQe-2500 series are high-speed and high-performance analog output multi-function DAQ PCI EXpress cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQe-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory.