Current
See Also: Direct Current, Alternating Current, Resistivity, Flow, Inductance
-
product
Meter Test Equipment
Signals & Systems India Private Limited
Our meter test equipment is a user-friendly and innovative device for energy meter calibration, built on the current technologies – Bluetooth & Android. The metrology sub-unit measures and communicates the parameters to an Android Tab via Bluetooth. All user interfaces – textual, graphical, and data entry are made available on the Android application, with innovative features. Being a portable device measuring the voltages and currents from the metering panel, the product ensures the safety of the test personnel by making use of wireless communication between the equipment – which is connected to the High Voltage- and the user interface – Tab.
-
product
Dual Mobile Communications DC Source w/ DVM
66309D
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66309D dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a half rack box) and eliminates the need for two separate power supplies.The 66309D dc source provides all of the capabilities of the 66309B with the addition of a built in digital voltmeter.
-
product
Autoranging System DC Power Supply, 80 V, 510 A, 15000 W, 400 VAC
N8951A
The Keysight N8900 Series is a family of 5 kW, 10 kW, and 15 kW autoranging, single-output power supplies available in 14 different voltage, current, and power combinations and either 208 VAC or 400 VAC (28 total models).
-
product
POWERSTROKE FUEL INJECTOR TEST KIT
DFST20
*Tests Powerstroke engines from 1994 to current*Includes adapters necessary to pressure test the fuel system*Adapters can be used for testing at both the fuel filter and at the fuel pump
-
product
Multifunctional testers
MI 3152 EurotestXC
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
product
PXIe 2 A Relay Module, 26xDPDT
42-139A-202
The 40-139A-202 (PXI) and 42-139A-202 (PXIe) are 26xDPDT relay modules suitable for high density switching applications with medium power and feature 2 A current capacity with voltage rating to 300 VDC/250 VAC
-
product
Universal Multichannel System up to 15 kV
- Up to 16 high voltage channels- 15 kV maximum output voltage- Maximum Current 1 mA- CPE, Radial Multipin or Kings connectors- Available with either positive, negative or mixed polarity- Up to 1 nA /100 pA current set / monitor resolution- Up to 200 mV/10 mV voltage set / monitor resolution- Low Ripple, down to < 10 mVpp- 2 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down (1 ÷ 500 V/sec) - TRIP parameter- Current generator operation in over current condition
-
product
SPA100
Our highly sensitive source picoammeter is designed for measuring and logging very small currents down to the pA range - making it an ideal instrument for scientific and research applications, including physics, materials science and electron microscopy. Full-featured at an affordable price, the SPA100 combines sensitivity, accuracy and stability to allow users to measure low currents with high precision as well as conveniently source bias voltages for experimentation. SPA100 also doubles as an ultra-high resistance meter, measuring accurately into the teraohm range. As with all our “headless” products, the SPA100 connects to PC via USB and utilises our complimentary software EPIC - enabling users to easily measure, graph and capture readings with timestamps and measurement stability information.
-
product
Test Bench Automation & Control Software
itk.TACware
Automation software for the effective, time efficient and user friendly operation of component test benches. The structure and implementation of the software is specifi cally optimized for highly dynamic test benches with high demands on control quality. Inparticular, itk.TACware provides a solution for test benches of medium degree of complexity (e.g. steering test benches and suspension strut test benches), that meets all current requirements for test bench automation.
-
product
Series Precision Fixed-Ratio Current Transformers
PMT25100
Power Measurement Technologies Inc.
Precision two-stage toroidal current transformers find application as the reference in determining the accuracy of instrumentation current transformers.
-
product
Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.
72-7226 CAL
The 72-7226 CAL from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.
-
product
Power Supply
EXC-PSM104P85S
The EXC-PSM104P85S is an isolated DC power supply specifically designed to provide reliable power for highly demanding PC104-Plus imbedded applications. The EXC-PSM104P85S has a wide input voltage range while providing robust and reliable power for embedded and industrial motherboards. The power supply is also fully compliant with MIL-STD-704A and E, MIL-STD-1275B and MIL-STD-461E.The EXC- PSM104P85S has totally independent safety features including input undervoltage lock-out, output overvoltage protection, output current limit protection, and temperature protection. Additionally, the Soft-Start function limits inrush current during startup.
-
product
Autoranging System DC Power Supply, 500 V, 60 A, 10000 W, 400 VAC
N8948A
The Keysight N8900 Series is a family of 5 kW, 10 kW, and 15 kW autoranging, single-output power supplies available in 14 different voltage, current, and power combinations and either 208 VAC or 400 VAC (28 total models).
-
product
Lock-In-Amplifiers
Current and voltage inputWorking frequency up to 45 kHzAdjustable sensitivity, time constant and phaseLocal and remote controlCompact and EMI-shielded case
-
product
Digital Volt Or Current Meter
CS1/CS2-VA
Measuring Voltage or Current for DC / AC / TRMS Accuracy: DC: +/-0.04% or AC: +/-0.1%; Display range: -19999~29999 User function, Easily programmable via the front panel. 1 relay, 1 Analogue output or RS 485 communication port in option with flexible functions. CE approved
-
product
VME64X 7U 8 slot with P0
101V64XM08-0621R
7U VME64x Backplane 8-slot with P0, compliant with ANSI/VITA 1.1-1997, VME extension, and VITA 1.7 Increased Current. The extra 1U provides room for extra power bugs or busbars. Includes termination passive inboard and daisy chain automatic active.
-
product
Transformer Turns Ratio Meter
TTRM 101
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1L-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Resonant Testing System
Originally designed to precrack specimens for fracture mechanics, the current versions offer much more possibilities due to a modular concept:*Bending up to 160 Nm*Tension/Compression up to 8 kN*Torsion
-
product
C/I Clamp Meters
*AC current measuring capability up to 400 amps*Compact size, fits easily into tool pouch*Data hold and Max hold to capture important readings*Lifetime Limited Warranty
-
product
Digital Multimeter
Basic
The digital multimeter (DMM) is an essential tool in every electronic enthusiasts arsenal. The SparkFun Digital Multimeter, however, is not your average multimeter, it features a loud continuity sound, current/voltage sense, and quality probes. You can use the multimeter to measure DC and AC voltage, DC current, resistance, continuity, and test diodes. With this version we've done away with the bright flashy colors that can get us into trouble and gone with a nice, neutral gray. This multimeter should provoke no strong feelings one way or the other, we know this because our guts say "maybe."
-
product
Single Channel Detectors
Infrared detectors for gas analysis, flame detection and radiometry in TO18 or TO39 packages.Housing types TO18 and TO39Voltage or current modeSignal processing with JFET or operational amplifierThermally compensated (optional)With special chip holder for reducing the microphonic sensitivity (optional)
-
product
Power Supply QD305 2x30V/5A
*on / off switch output section*two independent adjustable DC output*independent outputs serial and parallel*constant voltage and current*Low ripple and noise*four digit LED displays three*for 16 hours at full load*automatically search out
-
product
F-S General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
product
PXI Single 33x8 Matrix 2-Pole 1A
40-581-002
The Worlds highest density 2-pole single slot 3U PXI Matrix Module, the 40-581has 264 crosspoints configured as a 2-pole 33x8 matrix. The use of high density electromechanical relays means that the 40-581 is a low cost high density matrix solution with current handling up to 1 Amp. The 40-581 module is suitable for matrix applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based matrices do not have sufficient power handling capability.
-
product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25V-16
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
600 AMP MULTIMETER CLAMP
MD79
*Provides readings for volts, amps and ohms required for automotive electrical system tests*Handy 35mm AmpTip clamp jaws ergonomically measure at jaw tip for small sized conductors up to 60A and regular current, and Hz measures at jaw center for regular conductors up to 600A*Records max, min and calculates average readings over time
-
product
LV Iron Core Motor Starting Reactors
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
product
GPS/GNSS Antenna Signal Splitter 3-Way, TNC Female, IP67 Weatherproof, 1-2 GHz
GPS321
INSTOCK Wireless Components, Inc
GPS321 is a three way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power a remotely located active GPS antenna from one receiver while blocking the DC path from the other. Furnished with TNC female connectors all ports. A special feature of this unit is the 200 ohm internal load which provides a current drain for the GPS receiver not powering the active antenna. Some GPS receivers incorrectly sense an antenna fault when there is no current draw. The 200 ohm internal load provides a simulated antenna current drain which prevents receiver faulting. Max voltage rating at the DC blocked ports is 15 VDC; maximum current rating is 75 mA. Max voltage rating at the DC pass port is 50 VDC; max current rating is 2000 mA.