Showing results: 466 - 480 of 8141 items found.
-
Temp1000IS -
MadgeTech, Inc
The Temp1000IS temperature data logger is a rugged, submersible, battery powered, stand alone device which can be used to automatically record temperatures between -20 and 80°C. This all in one compact, portable, easy to use device is able to measure and record data for up to 32,767 temperature readings.
-
WISER 8000 -
TECAT Performance Systems, LLC
The TECAT WISER Model 8000 dual strain measurement and monitoring system is a wireless data acquisition system for measuring two external strain channels at high data rates up to 8kHz. The small, light, power-efficient, and non-invasive design enables strain measurements in a wide range of applications. With dual external sensor inputs two Micro-Measurements strain gauge bridges can be measured by a single system, for example to measure both thrust and torque loads simultaneously.The Model 8000 has a long range data transmission of >1,000 meters with up to +/- 0.025% FSR sensitivity for remote measurements. After initial setup using the WISER software interface, the system can be wired directly to your DAQ system, for seamless data collection.
-
IDC -
IDEAL NETWORKS
IDEAL Data CENTER (IDC) is the test result management software for LanTEK III cable certifiers from IDEAL Networks. IDC allows data cable installation professionals to easily download, manage, edit and print pdf reports. IDC offers a simple user interface with time saving features including; Microsoft ribbon toolbars; 4 button clicks to import data from the tester and 3 simple steps to create a professional report. IDC is the fastest management software from IDEAL Networks.
-
General Standards Corporation
General Standards Corporation is a leading supplier in data acquisition I/O boards, provides a complete family of data acquisition cards for sonar, industrial, and embedded applications on several form factors/busses, and for many operating systems. Functions available include analog I/O, serial I/O, and high speed parallel I/O.
-
UPC2100 -
Validyne Engineering
The UPC2100 PCI Sensor Interface card provides real-world data acquisition and control for your PC. Up to 16 sensor inputs in any mix or combination are accepted by the UPC2100. No external signal conditioning is required. The UPC2100 includes configuration and data acquisition software and is compatible with C#, .NET, C++, Visual Basic, LabView.
-
DataMan 2-D -
Cognex Corporation
In addition to breakthrough code reading, there are DataMan products for every step of the direct part marking (DPM) process, including quality verification, and data validation. Easy-to-use and reliable DataMan products enable quality control solutions for applications that require the highest read rates for 2-D Data Matrix codescritical to product traceability.
-
IQW -
Rohde & Schwarz GmbH & Co. KG
The R&S®IQW wideband I/Q data recorder is a versatile instrument for fast and reliable realtime recording, storage and playback of wideband I/Q data streams. In contrast to field tests, recording of live RF scenarios allows users to perform tests in the lab under real-world conditions reproducibly and at lower cost
-
Saildrone Inc.
Saildrone is the world leader in providing ocean data solutions with uncrewed surface vehicles, offering unrivaled payload, range, and reliability. Saildrone vehicles have sailed almost 1,000,000 nautical miles and spent almost 25,000 days at sea collecting data that provides unprecedented intelligence for climate, mapping, and maritime security applications.
-
EGMS -
MadgeTech, Inc
Egg Temperature and Humidity Data Logging System. Comes with two enclosure bases (vented for RH and non).
-
U3120M -
COMET SYSTEM, s.r.o.
The Datalogger is designed to record temperature and humidity humidity. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. It is possible to set the regular sending of JSON messages to Comet Database, the sending interval is adjustable.The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
-
EL-USB-3 -
Lascar Electronics Ltd
This data logger measures and stores up to 32,510 voltage readings over a 0-30V d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista.
-
Model 71862 -
Pentek, Inc.
The 71862 is a multichannel, high-speed data converter with programmable DDCs (digital downconverters). It is suitable forconnection to HF or IF ports of a communications or radar system. Its built-in data capture feature offers an ideal turnkey solution as well as a platform for developing and deploying custom FPGA-processing IP. XMC (VITA 42) with PCIe Gen 3 interface.
-
pHTemp2000 -
MadgeTech, Inc
The pHTemp2000 is a battery powered, stand alone pH and temperature data logger with an LCD. This all-in-one compact, portable, easy to use device will measure and record data up to 131,071 readings per channel. The pHTemp2000 will directly connect to many commonly used pH and ORP electrodes through a female BNC connector mounted on its side.
-
U3121M -
COMET SYSTEM, s.r.o.
The Datalogger is designed to record temperature and humidity from expternal probe. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. It is possible to set the regular sending of JSON messages to Comet Database, the sending interval is adjustable.The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
-
Monarch Instrument
The Track-It™ RH/Temp Data Logger is a battery powered stand alone compact data logger that records up to 32,000 samples each of Relative Humidity and Temperature data. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.