Current Injection
-
Product
Current Sensing Resistors, Thick Film Type
-
Panasonic Industrial Devices Sales Company of America
An AEC-Q200 Compliant SeriesPanasonic components specified as AEC-Q200 Compliant are consistently designed into automotive systems. However, today’s Design Engineers are specifying AEC-Q200 components to meet the high-quality standards of devices beyond automotive applications.
-
Product
DC BIAS CURRENT UNIT
3265B SERIES
-
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
Product
ABex Current Sense Module for Six Channel UUT Supply Monitoring
ABex TM-406 Current Sense
-
The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.
-
Product
Current Loop Expansion Kit
OP-SB85C
-
This expansion kit supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
Low Current Probe 80A
695
-
Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.
-
Product
Basic Fuel Injection Pressure Tester
FIT448
-
This set includes everything to test the following: Bosch AFC, MPC, Digijet/Digifant- (except CIS- use our FIT447) Chrysler Corporation Ford Motor Company General Motors (except TBI- use our FIT446) Japanese Fuel Injection Systems Others using Bendi. The 2-1/2" gauge has a dual scale dial with ranges from 0-100psi and 0-7 bar.
-
Product
Current Transformer
ST-9RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
Product
Mini AC Leakage Current Clamp Tester
M-100+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・18mmφCT window and ultra compact size.・Least affection from the external magnetic field.・The special alloy is used for core material that resists the rust over long period of use and ensures stable,high accurate measurements with very slight influence from aging.
-
Product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
Product
PXI/PXIe Battery Simulator Module, 4-Channel, Simplified Current Sink, 750 V Isolation
43-752A-902
-
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
30A, 100MHz High Sensitivity Current Probe
CP031A
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Current Sensors
-
Measurlogic offers an array of current sensors for every need, including split core, solid core and Rope current transformers (CTs); DC Shunts and Hall Effect Sensors. All of our electrical sensors are designed with an easy, un-intrusive installation in mind. With a low cost and high accuracy guarantee, we provide top of the line solutions for measurement and cost savings for residents and business owners alike.
-
Product
Mini AC Leakage Current Clamp Indicator
MLD-18
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・The LED will blink when detection leakage current exceeds AC 15mA.・Supports ELB with high-speed detection of 20ms.・The operating period is about one month, which is suitable for detecting intermittent leakage current.
-
Product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
-
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
400/5A CHEAP SPLIT CORE CAST RESIN CURRENT TRANSFORMER
LZCK310-10
-
Beijing GFUVE Electronics Co.,Ltd.
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
Product
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil
T3RC3000-HF
-
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil.
-
Product
Current Sensing Resistors, Metal Plate Type -MS, MB
-
Panasonic Industrial Devices Sales Company of America
An AEC-Q200 Compliant SeriesPanasonic components specified as AEC-Q200 Compliant are consistently designed into automotive systems. However, today’s Design Engineers are specifying AEC-Q200 components to meet the high-quality standards of devices beyond automotive applications.
-
Product
High Current / High Voltage Pulsers
DEI Division
-
Berkeley Nucleonics Corporation
is optimized for high impedance capacitive loads, driving extraction grids and deflection plates, and pulsing or gating power tube grids. It generates an output voltage of 6,000 volts with rise and fall times less than 60ns, with very flat voltage pulses from 160 nanoseconds to DC into a capacitive load.
-
Product
Current Probes
-
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.