Phantom Loads
generate different current values based upon the current rating of the energy meter under test. 2) standby power of a device turned off.
See Also: Parasitic Drain
-
product
48V / 200 Amp Load
BD12-48P
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 48V and 50V, (24 or 25 cells at 2V each), battery systems and is extremely cost effective.
-
product
ResMap or DualMap Auto Load Table Top
Creative Design Engineering, Inc.
*Type: Table Top*Wafer load: open cassette*Wafer size: 4" to 8"*Mini Environment: N/A *Probe Changer: N/A *Aligner: N/A*Size: 12" x 28" x 10"*Range: 1m/ to 10M/*Accuracy: 0.5%*Repeatability: 0.02% *Static Repeatability: 0.1% dynamic
-
product
Electronic Loads
SLM AC/DC
AMETEK Programmable Power, Inc.
From the leader in programmable power products, Sorensen introduces the SL series electronic loads which offer the best value with the most flexible platform. A wide range of loads are available from 75-1800W with both DC and AC input in benchtop, modular and standalone form factors.
-
product
Load Cell Indicator
9840
The 9840 is suitable for use in calibration labs, field service, or anywhere high accuracy is important. Features include a bipolar 6-digit 2-line display, remote sense, low noise, 22-bit resolution, USB port with RS232 communication, mV/V calibration and the ability to store up to 25 different sensors. 6-point linearization, unit conversion, front-panel tare. Self calibration via TEDS Plug & Play ready IEEE1451.4 compliance.
-
product
24V / 400 Amp Load
EL12-24M
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with Telecom 48V Rectifiers and Power Supplies with output Voltages in the range of 38V to 60V and is extremely cost effective.
-
product
48V / 250 Amp Load
EL15-48M
For Telecom Rectifier and Power Supply testing. This particular Load has been designed to operate with Telecom 48V Rectifiers and Power Supplies with output Voltages in the range of 38V to 60V and is extremely cost effective.
-
product
Load Cells
An array of load cells, including bending beam, tension and compression link, button, low profile, through hole, S type, cannister, tension link, and single point load cells as well as load pins.
-
product
Power Factor RLC Load
3282(280V,1875W / 3700VA )
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
product
400GbE Load Modules
Keysight Network Applications and Security
The Ixia 400GbE Jumpstart Test System is a developer tool kit to help network equipment manufacturers shorten development and test time – accelerating pre-standard 400GbE networking hardware. Now customers can create, test and verify the interoperability of their next Higher Speed Ethernet technologies while maximizing their 400GbE test investment.
-
product
FaithTech Regenerative High-power Programmable DC Load
FTR9000 Series
Shenzhen FaithTech Technology Co., Ltd.
FTR9000 series is a regenerative programmable DC electronic load. It not only has the function of traditional consumable load, but also cleanly feeds the energy consumed by traditional load back to the power grid to achieve the purpose of energy conservation. It can be widely used in new energy equipment testing, lithium ion, fuel and other battery discharge testing, automatic testing system, AC/DC, DC/DC and other one-way module product testing and aging. The product is equipped with rich communication, programming interfaces, color screens and a variety of text menu interfaces, which is easy to operate and intuitive. It is a common equipment in the power electronics, new energy, sensors, motor drives, system integration and other industries.
-
product
Dynacell Load Cells
2527 Series
Dynacell is the world's first truly dynamic load cell, designed from the outset for measuring dynamic loads. Dynacell introduces the following advantages: *Reduces dynamic load errors which can be a significant percentage of reading*Increases productivity by allowing higher frequency operation while maintaining test validity *Improvements such as doubling the frequency are common
-
product
Load Monitoring Units (LMUs)
Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability
-
product
AC Load Bank (Rack Mounted)
K-1000 Rack Mounted
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
product
DC Electronic Load
Model - KM-mPD-501
Kusam Electrical Industries Limited
KM-mPD-501 DC electronic load mainly focuses on the testing of power circuit on PCB. KM-mPD-501 offers a solution for function test of Switch step up, Stepdown, Regulators and Driver IC . Engineer puts components, such as CPU, DSP, FPGA; etc on a PCB after the power circuit has been tested. It’s not complete to use a meter to measure the voltage. KM-mPD-501 offers engineer OVP, OCP and OPP functions that help engineer know the value of overload current . On the other hand, engineer can use a programmable DC power supply (mPP series) to offer external power and connect PCB’s output to KM-mPD-501. Then engineer can easily get output watt, figure out the efficiency of power circuit and check if inductances, capacitances and resistances perfectly work with the power circuit. KM-mPD-501 not only offers loading emulation of current but also provides OVP and OPP. User can use these functions to test solar power battery, rechargeable battery and motor driver. In school laboratory, KM-mPD-501 helps students do experiment on power circuit, linear circuit and driver circuit.
-
product
Fully Automatic No Load ( Routine) Testing Panel For Self Priming Motors
Aarohi Embedded Systems Pvt. Ltd
Aarohi introduced fully automatic routine testing panel. The primary purpose of the routine test is to insure freedom from electrical and mechanical defects, and to demonstrate by means of key tests the similarity of the motor to a “standard” motor of the same design. this panel also help to enhance productivity, Work efficiency & reduces need for skill operator.
-
product
Digital Test Light With Load Tester
28800
Works as a regular test light and when you push the button on the tool it applies an 800mA load at 12V DC to easily check for voltage drop on circuits. The display will indicate the voltage drop when the button is pushed. Displays voltage under load to tell if circuit has problems like corrosion, resistance, or faulty connections. 48" cord with heavy-duty alligator clamp for secure connections. Not computer safe with load applied. Not for use on airbags.
-
product
Signal, Module, Receiver, QuadraPaddle, 90 Series, 192 Position, Fully Loaded w/ Twin Female Contacts
510150130
Primary mating module 510151105. (May mate with other ITA modules, as well.)
-
product
Load Cell & Microvolt Meter
A high-sensitivity 5-digit meter for use with load cells, strain gauges and microvolt input signals where high accuracy and stability are required. Load cell operation allows 4- or 6-wire hookup and display in engineering units, such as lbs, kg or psi. Built-in excitation for up to four 350-ohm load cells in parallel.
-
product
Load Cells
For use in harsh environments, our Models T66 (bending beam),T85 and T85-T(shear beams)are manufactured fromstainless steel, fully welded and hermetically sealed to provide total environmental protection (IP68 and IP69K). The T85-Tmodel has a blind loading hole, ideal for use in platform scales.
-
product
Oscilloscope, 350 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch DSO, Fully Loaded with 10.1" Color Display
T3DSO2354HD
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
Dual DC Electronic Load
3330F Series(40W~250W)
3330F Series Dual DC Electronic Load is a two load unit in one module. Each 3330F Series module has its own control and display panel, CC/CR/CV/CP/ Dynamic modes, plug in 3300F with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be remote controlled via RS232、Ethernet、USB and GPIB interface.
-
product
Mixed-Signal Active Load Pull System
MT1000 And MT2000 Series
The MT1000 and MT2000 mixed-signal active load pull systems are the best commercially proven solutions capable of performing load pull at high speeds of up to 1000 impedance/power states per minute with no limitation on Smith Chart coverage, under the following conditions:Single-tone CW and pulsed-CW RF signalDC and pulsed-DC biasTime-domain NVNA voltage and current waveforms and load linesFrequencies between 1 MHz and 40 GH
-
product
Advanced Diagnostic Load Cell Tester
LCT-U
The Advanced Diagnostic Load Cell Tester Model LCT-U is a stand-alone hand-held device specially designed for fast, comprehensive troubleshooting of strain gauge load cells. The LCT-U can quickly diagnose problems with all common types of load cell available today, including 6-wire load cells (with sense wires).
-
product
SIM, Module, Receiver, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510170102
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
product
48V / 200 Amp Load
BD12-48P
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 48V and 50V, (24 or 25 cells at 2V each), battery systems and is extremely cost effective.
-
product
Unclamped Inductive Load Tester
ITC55100STD
Model ITC55100STD performs ruggedness testing of power MOSFETs and IGBTs. It also tests single and dual diodes, and forward and reverse bias of IGBTs when used with an optional ITC55-RSF Output Selector Box.
-
product
Website, Mobile & Web App Load Testing
LoadComplete
LoadComplete helps you design and run performance, stress, and load tests for mobile, websites, and web apps. It's very easy to use. In fact, it is so easy, that you can create your first load test within a few seconds, even without any programming knowledge. LoadComplete allows you to generate load through virtual machines, on-premise computers, or even the cloud. It's compatible with leading continuous integration environments, which allows you to find root causes immediately.
-
product
Full Load Testing For Self Priming Pumps With Pneumatic System For Loading & Unloading Of Pumps
Aarohi Embedded Systems Pvt. Ltd
While manufacturing of self priming pumps testing time is very important to avoid bottleneck. Aarohi developed semi automatic performance testing system with pneumatic system for loading & unloading of pumps which helps to enhance productivity & work efficiency.
-
product
AC & DC Electronic Loads
The Adaptive Power Systems Electronic Loads cover a wide range of power levels, voltage and current profiles and feature sets.Supported voltages range up to 1250Vdc or 350Vrms AC. From bench to system and DC or AC requirements, we can more than likely offer you the optimal programmable load to meet your needs.





























