Showing results: 1411 - 1425 of 2280 items found.
-
40-873-002 -
Pickering Interfaces Ltd.
The 40-873-002 is a 4 to 1 RF MUX with 2 banks in a single PXI slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
40-873-102 -
Pickering Interfaces Ltd.
The 40-873-102 is a 4 to 1 RF MUX with 2 banks in a single PXI slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
YAVHF3X4 -
6TL Engineering
Fixture friendly. Use this product inside a Faraday chamber, and benefit from the fact that wiring in-out the chamber is drastically reduced! This module features three multiplexers in cascade configuration, for frequencies up to 2,5GHz. In/out is through SMB connectors, selectable for 75 and 50 Ohm. There’s direct control of the relays (24Vdc) or integrating CAN bus interface.
-
ABex AM-306 Relay -
Konrad Technologies GmbH
The ABex AM-306 is a performance relay card for signal interconnection up to 110V / 2A. The relay board has 100 channels divided into 88 single channels and 3 blocks witch 4 channels each which are switched to a common root (multiplexer).The ABex AM-306 is designed as a pin compatible replacement for the ABex AM-302 as well as the ABex AM-303.
-
40-788-021-T -
Pickering Interfaces Ltd.
The 40-788-021-T (PXI) and 42-788-021-T (PXIe) are single failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-021-T -
Pickering Interfaces Ltd.
The 40-788-021-T (PXI) and 42-788-021-T (PXIe) are single failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-788-022-T -
Pickering Interfaces Ltd.
The 40-788-022-T (PXI) and 42-788-022-T (PXIe) are dual failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-022-T -
Pickering Interfaces Ltd.
The 40-788-022-T (PXI) and 42-788-022-T (PXIe) are dual failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-788-122-T -
Pickering Interfaces Ltd.
The 40-788-122-T (PXI) and 42-788-122-T (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-042-T -
Pickering Interfaces Ltd.
The 40-788-042-T (PXI) and 42-788-042-T (PXIe) are dual failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-788-042-T -
Pickering Interfaces Ltd.
The 40-788-042-T (PXI) and 42-788-042-T (PXIe) are dual failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-122-T -
Pickering Interfaces Ltd.
The 40-788-122-T (PXI) and 42-788-122-T (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-121-T -
Pickering Interfaces Ltd.
The 40-788-121-T (PXI) and 42-788-121-T (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-788-121-T -
Pickering Interfaces Ltd.
The 40-788-121-T (PXI) and 42-788-121-T (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-041-T -
Pickering Interfaces Ltd.
The 40-788-041-T (PXI) and 42-788-041-T (PXIe) are single failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.