Showing results: 1441 - 1455 of 2277 items found.
-
42-785C-532-T -
Pickering Interfaces Ltd.
The 40-785C-532-T (PXI) and 42-785C-532-T (PXIe) are dual failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-542-T -
Pickering Interfaces Ltd.
The 40-785C-542-T (PXI) and 42-785C-542-T (PXIe) are dual failsafe SP6T 40 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-422-T -
Pickering Interfaces Ltd.
The 40-785C-422-T (PXI) and 42-785C-422-T (PXIe) are dual failsafe SP4T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-432-T -
Pickering Interfaces Ltd.
The 40-785C-432-T (PXI) and 42-785C-432-T (PXIe) are dual failsafe SP4T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-522-T -
Pickering Interfaces Ltd.
The 40-785C-522-T (PXI) and 42-785C-522-T (PXIe) are dual failsafe SP6T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-442-T -
Pickering Interfaces Ltd.
The 40-785C-442-T (PXI) and 42-785C-442-T (PXIe) are dual failsafe SP4T 40 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-451-T -
Pickering Interfaces Ltd.
The 40-785C-451-T (PXI) and 42-785C-451-T (PXIe) are single failsafe SP4T 50 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-552-T -
Pickering Interfaces Ltd.
The 40-785C-552-T (PXI) and 42-785C-552-T (PXIe) are dual failsafe SP6T 50 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-452-T -
Pickering Interfaces Ltd.
The 40-785C-452-T (PXI) and 42-785C-452-T (PXIe) are dual failsafe SP4T 50 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-572-T -
Pickering Interfaces Ltd.
The 40-785C-572-T (PXI) and 42-785C-572-T (PXIe) are dual failsafe SP6T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers a single slot.
-
40-785C-472-T -
Pickering Interfaces Ltd.
The 40-785C-472-T (PXI) and 42-785C-472-T (PXIe) are dual failsafe SP4T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-572-T -
Pickering Interfaces Ltd.
The 40-785C-572-T (PXI) and 42-785C-572-T (PXIe) are dual failsafe SP6T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-571-T -
Pickering Interfaces Ltd.
The 40-785C-571-T (PXI) and 42-785C-571-T (PXIe) are single failsafe SP6T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-571-T -
Pickering Interfaces Ltd.
The 40-785C-571-T (PXI) and 42-785C-571-T (PXIe) are single failsafe SP6T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
778572-46 -
NI
2.7 GHz, 50 Ω, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2546 is an RF signal multiplexer switch module. The multibank architecture of the PXI‑2546 makes it ideal for test systems that require parallel operations such as RF stimulus-response testing. The module also provides excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.