Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
J-Type Thermocouples (Ungrounded) (32 deg F to 900 deg F )
745685-J02
-
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
High Accuracy Vacuum Gauge
-
With a 0-100 mtorr (micron) range that dedicates virtually half of the scale to the 0-10 mtorr range, it is the most accurate thermocouple vacuum gauge available. It offers excellent accuracy in the sub-micron range (below 1 micron) and exceptional repeatability, making it a superior all around gauge.
-
Product
Temperature Input Device
-
The Temperature Input Device is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take temperature measurements with your PC. You can connect the Temperature Input Device to any USB port to use your PC as a display and monitor data in real time. The device is compatible with J, K, R, S, T, N, E, and B thermocouples.The Temperature Input Device includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
782975-01
Temperature Input Module
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
Brake Fluid Boiling Point Tester
6513C
-
Peaceful Thriving Enterprise Co Ltd
This tester can measure the boil point of the brake fluid. It can measure the wet boiling temperature of the brake fluid for technician as a reference for maintenance. It can be the reference when technician is going to change the brake fluid. Besides the brake fluid, user can also measure the temperature of other fluid by connecting the tester with K-type thermocouple.
-
Product
Ammeter
AC Rectifier Type Coil Meter
-
measures the alternating voltage and current with the help of rectifying elements and permanent magnet moving coil type of instruments. However the primary function of rectifier type of instruments work as voltmeter. Now one question must arises in our mind why we use rectifier type of instruments widely in the industrial world though we have various other AC voltmeter like electrodynamometer type instruments, thermocouple type instruments etc? The answer to this question is very simple and is written as follows.
-
Product
Instrumentation Tutor
-
Unitech Scales And Measurements Pvt. Ltd
This comprises of temperature and speed using different methods. RTD, thermistor and thermocouple are used as sensors with digital temperature indicator to measure temperature. A small water kettle is supplied as a temperature source upto 100°C. Glass bead thermometer is used as standard temperature measurement source to conduct the experiment. Magnetic and photo reflective sensors are used to measure speed. A FHP motor with speed regulator is used as speed source. To the shaft 60 teeth tone wheels are fixed to generate pulses.
-
Product
4 Thermocouples/RTD Ch
APCI-3200-4
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel4 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 2 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
Data Acquisition System
DAQ
Data Acquisition Module
Data Acquisition (DAQ) systems are used to collect information for the purpose of documenting or analyzing an electrical or physical phenomenon, for example: temperature or pressure. They serve as a focal point in tying a wide variety of sensors together that indicate temperature, flow, level or pressure. The sensors convert a physical occurrence into a measurable electrical signal, which can be factored into command and control decisions. These high-speed DAQ systems feature different analog and digital input and output modules that can be used with a wide range of signal types including 4-20 mA current, thermocouples, and RTDs.
-
Product
Handheld Calibrators
-
These handheld calibrators are perfect for calibrating thermocouples and RTD's in cases where the sensors are fixed or need to be calibrated on the spot. Locations such as factory floor or in the lab.
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745685-T01
-
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Precision Multi-Functional Manometer
DM 9600
-
Large 2.8” Color, touch screenTemperature compensated pressure sensorAutomatic zeroing for long-term stabilityTwo (2) K type thermo-couple socketsSimultaneous display of pressure and temperature readings1000 points and 500 sites data memoryMicro SD card slotUSB charging and data downloadHands free operation via magnetic back case20-hour Lithium battery
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-J
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
Full-Featured Thermocouple and Voltage Measurement Instruments
EX10XX Series
-
A wide range of measurement types, including pressure, strain, temperature, position and voltage, can be performed using this instrument when combined with the EX10SC signal conditioning expansion chassis. Each input incorporates an independent signal conditioning path with software selectable filters for maximum flexibility.
-
Product
Multimeter, Tester, LCR
-
7 digit resolution.Highly sensitive DCV and resistance measurements with 100 pV and 100 nOhm.1.3 nV eff , 8 nV peak-peak noise performance.Built-in low-noise 2-channel scanner.Direct SPRT, RTD , thermistor and thermocouple temperature measurement with 0.003 C accuracy.3 built-in low-power, dry-circuit test resistance functions.GPIB and RS232 interface.
-
Product
Balance Thermocouple Power Sensor, DC To 50 GHz
N8487S
Power Sensor
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
Product
Thermocouple Probes
-
sensor that measures temperature. It consists of two different types of metals, joined together at one end. When the junction of the two metals is heated or cooled, a voltage is created that can be correlated back to the temperature.
-
Product
PXI Millivolt Thermocouple Simulators
Series 41-760
Simulator
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
Product
PLC Input Modules
-
The DATEXEL DAT6000 series is a unique device designed to add analog inputs to a digital PLC with a few simple instructions. Downloaded into a standard PLC it is possible to acquire analog signals. The PLC will be able to read a 16 Bit digital input equal to the analog signal. The input, output and power supply are isolated from each other. The DAT6000 can linearize , filter and convert the input signal.The DATEXEL DAT6011 converts two voltages -50 mV to 50 mV, -100 mV to 100 mV, -500 mV to 500 mV or -1000mV to 1000mV or thermocouples K Type, J Type, S type, B type, R type, E type, T type and N type to a digital PLC.
-
Product
Smart Probes
-
A wide selection of rugged smart probes for your sensing needs. From non-contact IR sensors to a full range of sensor types including Temperature, Humidity, Process, RTD, Thermocouple, pulse.
-
Product
Independent 24-bit Sigma-Delta Type (One for Each Channel)
TR1
-
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
Product
Thermocouple (K-Type) And Temperature Probe Adapter
U1186A
Temperature Probe Adapter
Consists of a K-type thermocouple bead and a mini connector to dual banana plugs.
-
Product
Nickel & Thermocouple Alloy
-
Tempsens introduce our latest addition in our product-line i.e.“Nickel & Thermocouple Alloy”. We manufacturer a wide range of conductor in various types & sizes for high temperature application. We provide standard as well as custom made products according to the customer needs. Our lines are flexible and ready to meet the demand. Our manufacturing process conform to national & international standards for high quality Nickel & Thermocouple Alloy.
-
Product
Oxygen Analyser
Rapidox 2100
-
The Rapidox 2100 is a high-performance oxygen (O2) analyser fitted with a rugged long-life zirconia sensor on a remote cable, together with a type K thermocouple sensor; allowing direct in-process measurement of oxygen and temperature in the sample gas. The sensors provide fast and accurate analysis over the low ppm oxygen range in harsh environments up to 650°C.
-
Product
K Thermocouple Surface Probe
TP772
-
Surface thermocouple Type "K" probe. °C max: 400. Response time: 3 s.
-
Product
Thermocouple Alarm Setting Transmitter
Model TAT
-
Kusam Electrical Industries Limited
• 4 Digits Display For Input Signal:0 - 9999 • Output Signals Are Programmable. • Ultra-thin Dimension, 27mm width. • Non-Combustible PC Case .DIN Rail or Wall Mounting. • High Dielectric Strength ( AC 2KV / Min , Input / Output / Power )
-
Product
LXI Low Thermal EMF Matrix 1-pole 56x33
60-510-001
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
K Thermocouple Surface Probe
TP745
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
Thermocouple, Contact, ITA, Chromel, Type K (°C)
610113133
Thermocouple Contact (ITA)
Primary mating contact 610113131.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
Product
Shield
Arduino MKR Therm Shield
-
The MKR THERM Shield allows a board of the MKR family to acquire temperatures from a thermocouple of type K and a DS18Bxx digital one wire sensor. The Thermocouple is a kind of temperature sensor that offers high accuracy and a wide range of measured temperatures. Its analog nature requires specific interfacing and this shield relies on the MAX31855 thermocouple digital interface.





























