Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
Thermocouple Power Sensors
N8488A
-
N8488A power sensor has the widest frequency range among N8480 power sensors offering from Keysight.
-
Product
CAN TH MiniModules
-
CSM’s Thermo MiniModules (THMM) allow precise distributed temperature measurements with K-, J- and T-type thermocouples: ideal for measurements in the powertrain, on HVAC (Heating, Ventilation, and Air-Conditioning) components, in the vehicle interior, the powertrain development and many more.
-
Product
REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O
784750-01
-
4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.
-
Product
3-Slot Data Acquisition Mainframe With GPIB, Two 20-Channel Switch Modules, And One 20-Channel Multiplexer Module
DAQ973SB
-
The DAQ973SB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, two 20-channel DAQM903A Actuator / GP switch modules, and one 20-channel DAQM901A multiplexer module. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junction20-channel actuator / general-purpose switch with independent single-pole, double-throw (SPDT) relaysbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
Product
K Thermocouple Immersion Probe
TP656/1
-
“K” Type thermocouple imemrsion probe. Tolerance according to IEC 60584-2 standard. °C max: 1000. Response time: 1 s.
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
-
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
U1180A Thermocouple Adapter And Lead Kit, J And K Types
-
The Keysight U1180A thermocouple adapter and lead set are compatible with all series of Keysight Handheld Digital Multimeters. The set includes a J/K type Thermocouple adapter, thermocouple bead J-type and a thermocouple bead K-type.
-
Product
Input / Output Modules
-
*Competitive cost-per-channel*24-bit A/D converters; 16-bit exported*ICP, Strain Gauge, Frequency, String Pot, Thermocouple*Portable, rugged, stand-alone operation*Open-source command set for third-party software applications
-
Product
Temperature Measurement
K- TC8
-
The K-TC modules belong to the Influx K-series instrumentation range for CAN applications. The stackable K-TC is an ideal for those applications that require a large number of thermocouples for example vehicle durability, winter and summer testing.
-
Product
MAX31855 K-Type Thermocouple Arduino Shield
SEN-30004-K03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855K supports a measured temperature range of -270C-1372C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
K Thermocouple Surface Probe
TP647
-
Surface thermocouple Type “K” probe. Fiberglass cable. Tolerance according to IEC 60584-2 standard.
-
Product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
-
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Product
Data Acquisition Systems
-
Encore Electronics manufactures a wide range of analog signal conditioning equipment, including strain gage and pressure amplifiers, frequency-to-voltage converters, thermocouple isolation amplifiers and anti-aliasing filters.
-
Product
16 Channel Isolated Thermocouple And Voltage Measurement Instrument
EX1401
-
The EX1401 delivers accuracies of ±0.20°C, 1000 V channel-channel isolation, built-in self-test capabilities, and independent 24-bit ADC’s per channel. Its ability to acquire data at 20K samples/second/channel allows its usage in high-speed temperature transient applications. Deploy it in a variety of applications, including automotive and battery testing, jet engine testing, highly accelerated life test/highly accelerated stress screening (HALT/HASS), and health monitoring. It can be used in any test environment that requires accurate temperature measurement and repeatability. Parallel data storage and standalone autonomous operating modes further expand the utility of this versatile instrument.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44
-