Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
-
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
6-Ch Thermocouple Input EtherCAT Slice IO Module
AMAX-5018
-
Channels: 6 differentialInput Type: V, mV, ThermocoupleInput Impedance: >2MΩVoltage Range: ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 VResolution: 16-bitFSR accuracy: 16-bit with ±0.1% @25°CSample Rage: 100 Sample/Second (per channel)
-
Product
Signal/Thermocouple, Module, Receiver, TriPaddle/ Thermocouple, 84/12 Position
510104261
-
Signal/Thermocouple, Module, Receiver, TriPaddle/ Thermocouple, 84/12 Position
-
Product
Handheld Calibrators
-
These handheld calibrators are perfect for calibrating thermocouples and RTD's in cases where the sensors are fixed or need to be calibrated on the spot. Locations such as factory floor or in the lab.
-
Product
Digital Multimeters
-
*5½-digit resolution to 8½-digit resolution DMMs*6ppm basic voltage measurement accuracy on the 8½-digit DMM for calibration laboratories*Fast, 1 Msample/s sampling speed to capture complex, low level current profiles from IoT devices or other wireless devices*Sensitivity of 1 µΩ and 1 pA to test low power devices for research, design, and manufacturing test*A wide range of measurement functions such as DC and AC volts, DC and AC current, two- and four-wire Ohms, continuity, frequency, period, RTD, thermistor, and thermocouple temperatures, diode test, and capacitance*Numerous interface options including LAN/LXI, USB-TMC, GPIB, and RS-232 for data acquisition and automated testing*Intelligence to execute tests and create customized measurements with minimal PC interaction*Measurement expansion up to ten channels
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
NI-9219, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module
779781-02
-
100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.
-
Product
E-Type Thermocouple, 32°F to 900°F Temperature Sensor
745690-E001
-
E-Type Thermocouple, 32°F to 900°F Temperature Sensor - The E-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the E-Type Thermocouple and acquire synchronized temperature data in units of degrees. The E-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Trip Amplifiers
-
Datexel manufacture a large range of Trip Amplifiers and Process Limit Alarms that accept universal inputs and provide either relays or NPN or PNP transistor outputs. The DAT5028 is also an isolated signal converter and has a local display with up to 4 relays and is DIP switch programmable. The inputs can be Thermocouples, RTD, mV, mA, Resistance, Potentiometers or Voltage. They can be supplied fully configured set up by PC or DIP switches. The DAT5024 is a trip Amplifier / Temperature limit alarm for RTD's, Thermocouples, Voltage, Resistance and Current with the option of 1 or 2 relay outputs hysteresis and delay timers. The DAT5024 E range is an economical choice with DIP Switch programmable for voltage or current input. Either 1 relay or 2 relays (SPDT) are available with delay timers.
-
Product
Thermometer Kits With Meter
-
Thermometer Kits with Meter. Products include the HVAC Standard and PRO kits, Type K general purpose thermocouple kit and two multi-purpose kits with optional moulded on probes or hand held temperature probes, Catering Kit with High Accuracy Chef Thermometer and optional Type T probes, Legionella Kit with integral timer, probe and moulded-on thermocouple
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745690-T002
-
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Tempical® Tester
H394
-
Precision Testing For: Thermal Switches, Chromel®-Alumel® Thermocouples, and Continuous-Wire Fire Detection Systems.
-
Product
OEM 1-Channel Fiber Optic Signal Conditioner PCB Module
FOTEMP1-OEM-MNT
-
The FOTEMP1-OEM-MNT is a small form factor PCB interface module designed for low cost insertion of high precision GaAs-based fiber optic temperature sensor technology into OEM applications where common electrical temperature sensors and thermocouples cannot be used. The OEM interface product is compatible with all TS series fiber optic temperature probes. The sensors are entirely non-metallic and electrically passive, providing immunity to EMI, RFI, MR, microwaves and radiation is required.
-
Product
K Thermocouple Surface Probe
TP655
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
Thermocouple Wires & Connectors
-
Is designed for sensor manufacturers for the production of commercial grade thermocouple junctions, and for users of large numbers of exposed junctionthermocouples such as test & development laboratories where multipoint temperature sensing of test pieces is required.
-
Product
Signal Conditioners
-
Datexel has a large range of Signal Conditioners. We manufacture Thermocouple Transmitters, that are either Head Mounted, Din Rail and we even have an OEM version that can fit inside an enclosure smaller than 1" x 1/4". These Temperature Transmitters are PC programmable or DIP Switch programmable. Some are isolated and accept input from various sensors such as RTD's, Thermocouples Voltages, Current, Resistance and Potentiometers. They have current outputs and we even have Temperature converters that have voltage outputs.
-
Product
Temperature/Limit Controller
16L
-
The 16L Series Temperature/Process FM Approved Limit Controls set a new standard in 1/16 DIN limit controls. The 16L offers universal input (10 thermocouple types, 4 RTD types, voltage, and current), single set point or dual set point
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745685-T01
-
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-J
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
Temperature and Process Controllers
-
The ATR121 Temperature Controller is a 3 digit display PID controller with up to 2 relay outputs, Solid State Output and an option to be a Modbus RS485 Slave device.The ATR141 Temperature Controller is a 4 digit PID controller and Panel Meter which can display up to 3200°F with an S Type Thermocouple. The ATR141 can have up to 2 relays, a Solid State Output and an option to have a Modbus RS485 output.
-
Product
Boiler Thermocouple Monitoring System
BTM
-
The Boiler Thermocouple Monitoring System is used to acquire and archive data from thermocouples mounted on boiler tubes. Since this system interfaces directly with Allen Bradley Control Logix PLCs via EthernetIP communication, significant cost savings can be achieved by using it as remote IO.
-
Product
High Current Transformers
-
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
Product
General Purpose Probes
PIT-12
-
PIT-12 General Purpose Probe for Pressurized Systems - 12'' #304 stainless steel shaft. Diameter is 1/16''. Immersible. Maximum temperature 350°C, Time constant 0.5 Seconds. Shaft Terminated in a sub-miniature Type T Thermocouple plug. 10 foot Sub Miniature Type T extension lead supplied. Not isolated.
-
Product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30003-J
-
Breakout board for the MAX31855J digital thermocouple interface ICs by Maxim. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws. The SEN-30003 is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance (many other level shifters reduce data rates to below 500 kHz).
-
Product
PXIe-4303 , 24-Bit, 32-Channel, 51.2 kS/s, ±10 V PXI Analog Input Module
783866-01
-
24-Bit, 32-Channel, 51.2 kS/s, ±10 V PXI Analog Input Module—The PXIe‑4303 is a filtered input module for voltage, thermocouple, and current measurements. The module offers you the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.
-
Product
Panel Selector Switches
Model 767S
-
The 767S Panel Mounting DIN sized selector switches provide convenient, reliable selection of up to 12 thermocouple or RTD (Pt100 etc) inputs. The front panel rotary switch provides easy selection and clear indication of the desired channel.
-
Product
Digital Temperature Sensor
ZET 7020
-
Digital temperature sensor ZET 7020 is designed for measuring temperature of liquid, solid, gaseous and granular mediums, which are safe for the material of thermocouple casing. Application spheres: heat power energy, chemical and metallurgical industry.
-
Product
K Thermocouple Surface Probe
TP746
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
PXI Millivolt Thermocouple Simulator Module - 8 Channel
41-760-004
-
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.