Partial Discharge
voltage discharge within an insulator causing dielectric breakdown.
See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test
-
Product
Partial Discharge Measurement Calibrator
DAC-CP-2
-
DAC-CP-2 is a calibrator for partial discharge measurements.The electric charge enables to generate up to max 10000pC.It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
-
Product
Partial Discharge Solutions
-
From software systems to hand-held instruments, we’ve developed industry-leading technology to help you keep on top of ageing assets. Spot the warning signs, including partial discharge, to manage maintenance and make timely repairs.
-
Product
Universal PD & EMI analyzer
Spark P3
-
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
Product
Tan Delta Measurement
TD Series
-
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
Product
Solution for Industrial Monitoring
PDScope
-
Techimp PDSCope is a brand new product of the PDCheck family particularly designed to suit all the requisites of the Techimp TiSCADA systems for on-line monitoring of diagnostic quantities in electrical assets.Techimp PDSCope is a powerful PD analyzer based on Techimp TF Map technology (patented) allowing preliminary noise rejection and automatic calculation of statistical parameters relevant to Partial Discharges.
-
Product
Partial Discharge Testing Equipment
AR700
-
PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.
-
Product
High Frequency Current Transformer
HFCT
-
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
Product
Lightning Rod Flaw Detector
PADD
-
We developed the PADD for the detection of internal and external partial discharges on metal oxide lightning rods. Defects can cause radio interference in communication systems or TV images, interference whose origin is very difficult to locate. We have developed a unique technology for detecting radio frequencies for use under voltage.
-
Product
Flexible Magnetic Coupler
FMC
-
The FMC (Flexible Magnetic Coupler) is a partial discharge sensor whose working principle is based on a direct magnetic coupling with the cable conductor and shield.It picks up a magnetic signal given by PD activity. His compact and robust design makes the FMC the optimal sensor for direct installation on cables and accessories such as joints and termination.This sensor has a sensitive side which has to face to the object under test, while the other side (shielded) reject the noise from the environment.
-
Product
Partial Discharge and Tan Delta
PDIX Series
-
PDIX is a combined partial discharge and tan delta cable diagnostic testing system. By combining HVI’s VLF products with PDIX products, users can perform VLF AC withstand, partial discharge detection, and tan delta measurement on medium and high voltage cables, rotating machinery, and other apparatus with one integrated package fully supported by HVI & PDIX.
-
Product
TE-Metrology
-
HIGHVOLT Prüftechnik Dresden GmbH
The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components
-
Product
Partial Discharge Monitor
INDIPARD
-
INDIPARD, a low-cost measuring device for partial discharge monitoring.
-
Product
Partial Discharge Tester
GTPD-2C
-
GTPD-2C Digital partial discharge tester is the digital partial discharge measuring and analyzer adopting the complete new generation technology. It is suitable for partial discharge detection in manufacturing factory and field handover test of transformers, generators, CT/PT, bushings, GIS, capacitors, power cables, switches and other high-voltage electrical equipment with various voltage levels and capacities.
-
Product
Partial Discharge Tester
19501-K/19500
-
Chroma 19501-K partial discharge tester combines hipot test and PD (partial discharge) detector functions in one instrument. The device is capable of a maximum 10kV AC output with leakage current measurement range of 0.01uA and a minimum partial discharge detection of 1pC. The tester is specifically developed to test high voltage semiconductor components and high insulation materials.
-
Product
Partial Discharge Meter
APD-LT
-
The APD-LT equipment is a partial discharge meter in cable accessories (heads or insulators) to improve safety and maintenance. The PD level is presented numerically in the wireless unit.
-
Product
Partial Discharge Inductor
Tracy
-
Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories
-
Product
Insulation Resistance Meter
AMIC-15k1
-
The partial discharge indicator PDI. Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD. Allows to test the electrical durability of the tested object - indication of breaking voltage. The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.
-
Product
Shielded Rooms
-
HIGHVOLT Prüftechnik Dresden GmbH
Electromagetic field and line-conducted interference needs to be eliminated in order to measure low-intensity partial discharges with a PD background noise level (≤ 1 pC) in accordance with IEC 60270.
-
Product
Partial Discharge Detector
APD-ANNUNCIATOR
-
The APD-ANNUNCIATOR is a remote partial discharge detection equipment inside any energized cabinet. The probe is installed in the unit under test, instantly reporting its status. This equipment gives a great benefit because it avoids long term damage to the switching equipment.
-
Product
Ultrasonic Leak Detection Camera
Leakshooter LKS 1000-V.2
-
1st ultrasonic compressed air, gaz and vacuum leak detector with camera. Specialy dedicated to visualize the spots where compressed air is leaking, the LEAKSHOOTER LKS 1000 – V.2 has many other applications such as : steam trap monitoring, bearing monitoring, electrical applications like partial discharge, corona effects, punctured isolators, electrical tracking detection.
-
Product
PD Measuring System
TEM
-
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
Product
Conventional Power Supply Design with Simple Analog Controls
VLF Series
-
VLF hipots perform voltage withstand tests and provide the voltage source for diagnostic cable testing. There is no better method for verifying the AC integrity of a cable than applying VLF AC voltage. Tan delta and partial discharge measurement accessories are frequently purchased along with VLF equipment to extend their capabilities.
-
Product
Partial Discharge Detector
PDD 100
-
The Insulator partial discharge detector is a state-of-the-art technology used by NASA. The Parabolic design of the disc helps to maintain and detect ultrasound from safe distance of 100 Meters. Enhanced ultrasound detection is provided to the device, by combining the features of the already proven Ultra sound sensing technology with extended range and sensing capabilities. A pistol like grip laser pointer, and rifle sights make the Insulator partial discharge detector easy to handle and use.
-
Product
TEV Antenna
-
TEV sensor is a partial discharge sensor whose working principle is based on a direct Capacitive coupling with a Switchgears earthed metal case. The two ends of TEV sensor can be coupled magnetically to virtually any opening on a metal Surface. It picks up the electric signal given by PD activity onto the two metallic surfaces. Thanks to its special design has high sensitivity, larger than other single ended TEV sensors. His compact and robust design (passive sensor) makes the TEV the optimal sensor for direct installation on medium voltage Switchgears.
-
Product
Acoustic Imaging Cameras
Si1 and Si2 Camera series
-
Helps you significantly lower costs associated with mechanical bearing issues and partial discharge on electrical equipment. It also enables you to drastically reduce leaks in your facilities, cutting down expenses related to compressed air and gas leaks.
-
Product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
-
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
Product
Inductive Sensor
HFCT Ø 30-39-50mm
-
Techimp HFCT is an inductive sensor for partial discharge measurements. It is suitable for on/off line PD tests on many electrical systems (cables, transformers, rotating machine, etc..). It has to be applied to the ground connection of the system to be tested.
-
Product
PD Monitoring systems
TECHIMP PD Hub™
-
Techimp’s Partial Discharge (PD) Monitoring systems usually consists of a Central Unit and distributed Data Acquisition Units – the PD Hub™ - able to acquire and process the PD signals locally detected through PD sensors installed on each of main electrical assets (generator, transformer, HV cables and GIS).
-
Product
Partial Discharge Test Set Up
-
This testing set is of great use in industries for various testing applications. We strictly follow all the guidelines while manufacturing this Partial Discharge Test Set Up.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).