Reactive Load Banks
Provide both lagging and leading power factor loads.
See Also: Load Banks, AC Load Banks, DC Load Banks, Inductive Load Banks, Resistive Load Banks
-
Product
Type 12R2, 8U, 19" Rackmount, MIL-Rugged, Top Load
12R2-8U-TL
-
The 8U, 12R2 is designed to meet the harsh environment of shipboard, airborne, and ground mobile applications per MIL-STDs. Shock isolated versions are designed to attenuate 25G shock inputs to the chassis to less than 10Gs at the card cage.
-
Product
High Power DC Electronic Load
3350G Series(4KW~6KW)
-
Each 3350G Series module has its own control and display panel, CC / CR / CV / CP /Dynamic modes, also can be controlled via RS232、Ethernet、USB and GPIB interface.
-
Product
Signal, Insert, Receiver, QuadraPaddle, SIM, 1 Slot (not loaded- for discrete wiring only)
510180101
SIM Insert
Signal, Insert, Receiver, QuadraPaddle, SIM, 1 Slot (not loaded- for discrete wiring only).
-
Product
Load Cell
-
Precise and robust and it has been designed to meet the requirements of a wide range of industrial weighing applications: hoppers, tanks, platforms. Is able to work in severe environmental conditions typical of applications in food, chemical and pharmaceutical industries.
-
Product
LED Load Simulator
63110A/ 63113A/63115A
Simulator
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is unable to simulate turn on or PWM brightness control characteristics. This may cause the LED driver to function improperly or trigger it’s protection circuits. These testing requirements can be achieved when using a LEDs as a load; however, issues regarding the LED aging as well as different LED drivers may require different types of LEDs or a number of LEDs. This makes it inconvenient for mass production testing.
-
Product
Bottle Vertical Load Testers
-
Bottle Vertical Load Tester measures the vertical load strength of glass containers, simulating capping and stacking loads.
-
Product
Low Profile Compression Only Load Button Load Cell with Mounting
LBO SERIES
-
The LBO Series (Load Button) load cells are offered for compression only applications where space is limited. Matching surface must be flat and at least the diameter of (D1). The loading diameter (D2) is slightly convex for accurate load distribution. Threaded mounting holes are provided on the bottom surface for fastening down from beneath. These sensors are manufactured from heat treated 17-4phstainless steel and sealed for use in mostindustrial environments.
-
Product
Single Point Aluminium Load Cell
EST-6
-
Technopark Automation & Control
The EST-6 is a Single Point Aluminium Load Cell suitable for use on platform scales measuring 600 x 500 mm. This load cell is available in capacities 500 kg and 1000 kg.
-
Product
Medium Voltage Load Banks
-
Guangdong EMAX Electrical Co., Ltd.
Optimize your medium voltage power systems with our Container Load Banks. Engineered to perfection, these load banks offer advanced features and robust performance, ensuring accurate testing and maximum reliability. Unleash the power of excellence.
-
Product
Automated Tuners / Impedance Tuners / Load Pull Tuners
-
MT97x, MT98x and XT98x series automated tuners (also known as automated impedance tuners and automated load pull tuners) are precision instruments that are optimized for a broad class of in-fixture and on-wafer applications, and may be used in any automated or manual application requiring the ability to match the impedance of a microwave circuit element or to establish specific impedances at a terminal interface. The tuner design is based on the slide screw concept using the inherently broadband slab-line transmission structure. Each unit has two non-contacting probes deliver high VSWR with superb accuracy and reliability over a wide frequency range. These probes can be fully retracted leaving a low-loss, well-matched transmission line, which is a significant benefit in power related applications where two-port tuners capable of handling large amounts of power are required. As integral components of Maury Device Characterization Solutions, these PC-based tuners are controlled using Maury's family of Device Characterization Software tools, including MT930 IVCAD, MT993 ATS and the DLL-based measurement automation environment. Maury Microwave automed impedance tuners are ideal for load pull, harmonic load pull, active load pull, hybrid active load pull, noise figure, noise parameters and all automated tuner applications.
-
Product
SMART Constant Current DC Load Banks
SLB-Series
-
SMART Constant Current DC Load Banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other testing for DC power with load. The SMART technology allows a constant current discharge without the need for manual adjustment of current during the discharge test. Our SLB-Series load banks are portable, durable, economic, safe, easy-to-use and come complete with our DataView software, providing the user with a complete data management and analysis program.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-200B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
8 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 8 Ports
GPS812
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
460V / 18 Amp Load
EL08-460M
-
For High Voltage UPS Battery Testing and Power Supply testing. This particular Load has been designed to operate with UPS Battery Systems and Telecom Rectifiers and Power Supplies with output Voltages in the range of 307V to 460V and is extremely cost effective.
-
Product
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not Loaded- For Discrete Wiring Only)
510181101
SIM Insert
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not loaded- for discrete wiring only)
-
Product
Road Load Data / Durability
-
Vehicle Durability Testing and Road Load Data AcquisitionA road load data acquisition system from Dewesoft is a perfect vehicle durability testing solution for real-drive tests or tests on the road simulator test benches. Our advanced DAQ technologies will shorten time to test dramatically and make sure you get the correct measurements right the first time.
-
Product
Digital Test Light With Load Tester
28800
-
Works as a regular test light and when you push the button on the tool it applies an 800mA load at 12V DC to easily check for voltage drop on circuits. The display will indicate the voltage drop when the button is pushed. Displays voltage under load to tell if circuit has problems like corrosion, resistance, or faulty connections. 48" cord with heavy-duty alligator clamp for secure connections. Not computer safe with load applied. Not for use on airbags.
-
Product
Load Cell Displays
-
We carry a wide range of digital displays for strain gage load cells. There are many options available to our load cell displays such as analog outputs to interface with a PLC, digital outputs for computer interfaces, I/O and relay outputs to control batching and checkweighing scales, and wireless load cell indicators.
-
Product
Mini Load Column Load Cell Compression Only with Mounting
MLC SERIES
-
The MLC Series is our miniature high capacity compression only load cell/force sensor, featuring low profile compact size for a wide range of portable and dedicated applications up to 30,000 lb The load diameter is slightly convex for accurate load distribution. Low deflection through design results in ultra fast frequency response. The MLCs are designed to be mounted in a shallow machined flat pocket or smooth flat surface, either free or fastened via a bottom 6-32 tapped hole. These load cells are manufactured from heat treated 17-4 ph stainless steel. The sensing element incorporates bonded foil strain gages of the highest quality and are sealed for protection against most industrial Environments.
-
Product
Signal Module, ITA, QuadraPaddle, 90 Series, 192 Position, Fully Loaded with Round Posts (610 138 115)
510151107
ITA Module
Used together with QP ITA module p/n 510109316 for PCB mounting. NOTE: Mounting screws for this module are included with module part # 510109316. Primary mating module 510150115. (May mate with other Receiver modules, as well.)
-
Product
Portable Three Phase Phantom Load Power Source
SY2103
-
Hong Kong Songyang Industrial Ltd.
The new SY2103 series portable three phase phantom load stable power source, designed from new digital wave compound technology and according to International Standard, is newly intelligent equipment for energy meters. The equipment includes voltage/current source & standard meter, operated easily through front panel to preset directly all data of meter under test and test process.
-
Product
Unclamped Inductive Load Tester
ITC55300C
-
Model ITC55300C performs ruggedness testing of power MOSFETs, discretes and modules and IGBTs, discretes and modules. It also tests single and dual diodes, and forward and reverse bias of IGBTs when used with an optional ITC55-RSF Output Selector Box.
-
Product
Dual DC Electronic Load
3330F Series(40W~250W)
-
3330F Series Dual DC Electronic Load is a two load unit in one module. Each 3330F Series module has its own control and display panel, CC/CR/CV/CP/ Dynamic modes, plug in 3300F with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be remote controlled via RS232、Ethernet、USB and GPIB interface.
-
Product
Hand-Held/Digital Load Tester
6030
-
• Full 125 Amp load tests 12 Volt batteries, alternators and starters on all type of vehicles• PATENTED• Made in USA of US and Global Components
-
Product
PXI 18 Bank, 3 Channel, 1 Pole Multiplexer
40-617-021
Multiplexer Module
The 40-617 18-Bank, 3-Channel, 1-Pole Multiplexer Module forms part of the System 40 PXI Programmable Switching system. The Module consists of 18 electrically isolated banks of multiplexers controlled by a PXI/PCI interface. Each bank is a 1 to 3 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously. Inter-bank linking relays allow multiplexer size to be increased in multiples of 3 by joining the common terminals of adjacent banks. Closing one linking switch produces a 6 channel multiplexer, closing all linking switches produces an 54 channel multiplexer.
-
Product
Load Cell Amplifier
-
Xiamen Elane Electronics Company, Ltd
: 0-50 degrees. Humidity: 30 to 80 percent, non-condensing.Power Supply Requirements:Power Supply voltage: 9 volts DC.Operating current: 5mA, plus bridge current.Bridge Input:Excitation voltage: 5 volts.Bridge Type: Full Wheatstone Bridge.Voltage Output Range: From 0 volts to 4.3 volts.