-
Product
PXIe Short SMU
52403P
Source Measure Unit
Chroma's 52403P is a PXI Express Short Pulse SMU (Source/Measure Unit) designed for fast, precise and reliable sourcing and measurement of thermo-sensitive devices such as high-power laser diodes (LD). Integrating a high-speed pulser, a high precision SMU and a DAQ module into a single PXIe SMU, the 52403P can measure both the LIV and the low-level leakage current of a high-power LDs.
-
Product
High Speed Insert, Receiver/ITA, SIM, VTAC, Retention Insert
610151105
SIM Insert
The miniature size of the SIM PCB Adapter greatly benefits from the addition of the VTAC Retention Insert. The VTAC Retention Insert helps to provide rigidity and reinforce the connections between 610151103 and 610151104. Works with Right Angle VTAC.
-
Product
Signal, Insert, Receiver, QuadraPaddle, SIM, 1 Slot (not loaded- for discrete wiring only)
510180101
SIM Insert
Signal, Insert, Receiver, QuadraPaddle, SIM, 1 Slot (not loaded- for discrete wiring only).
-
Product
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)
510181111
SIM Insert
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)Compatible with 410130116, ITA, i2 MX, 22 Slot VTAC/SIM Insert, EMI, and XL version 410130133Not loaded. Thermocouple patchcords need to be purchased separately.
-
Product
Dual Function Slot MOSA Nano Remote Data Concentrator Unit (RDC)
NIU2A-RDC-01
Data Concentrator Unit
NIU2A-RDC-01 is a Modular Open Systems Approach (MOSA) Remote Data Concentrator with low power high performance ARM Cortex -A9 processing. 512 MB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet and optional Fiber Optic Ethernet support.
-
Product
Tool, Insertion, QuadraPaddle, ITA, Wire Wrap Contact
910113106
Insert Tool
Tool, Insertion, QuadraPaddle, ITA, Wire Wrap Contact - this tool is used for insertion of QuadraPaddle ITA Wire Wrap Contacts (P/N 610138122).
-
Product
Source Measure Units and LCR Meters
Source Measure Unit
Source Measure Units are high-precision, high-accuracy DC instruments that can both source and simultaneously measure voltage and current. Additionally, LCR Meters can measure the inductance, capacitance, and resistance (LCR) of electronic equipment.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not Loaded- For Discrete Wiring Only)
510181101
SIM Insert
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not loaded- for discrete wiring only)
-
Product
Signal/Mini Power/ Mini Coax, Module Insert, Receiver, i2 MX, TriPaddle, 8/8 Position
510143005
Receiver Module Insert
Signal/Mini Power/ Mini Coax, Module Insert, Receiver, i2 MX, TriPaddle, 8/8 Position.
-
Product
PXIe Source/Measure Unit, 15 MSa/s, 1 PA, 60 V, 3.5 A DC/10.5 A Pulse
M9602A
Source Measure Unit
The Keysight M9602A is a PXIe SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
Source Measure Units (SMUs)
B1511B
Source Measure Unit
The SMUs of B1500A integrate 4-quadrant voltage/current source and measurement capabilities for accurate IV measurement with the range of 0.1 fA - 1 A / 0.5 µV - 200 V. It supports spot, sweep, pulse sampling and QS-CV measurements.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
PXIe 5-channel Precision Source/Measure Unit, 500 kSa/s, 10 pA, 30 V, 500 mA
M9615A
Source Measure Unit
The Keysight M9615A is a PXIe five-channel precision source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 uV / 10 pA.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
4- Channel PXI Source Measure Unit (SMU)
GX3104
Source Measure Unit
The GX3104 is a precision 3U PXI module that forces and senses both voltage and current over a range of ±20 V and up to ± 1 A ( channel 1) with channels 2- 4 capable of supplying up to 500 mA. Total available output current from the module is 1A. The four channels are electrically isolated from the PXI power supply and share a common, isolated ground.
-
Product
PXIe High-Speed Source/Measure Unit, 13 V, ± 1 A or 6 V, ± 3 A, 18 W
M9111A
Source Measure Unit
The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.
-
Product
Source/Measure Unit for Battery Drain Analysis, Multiple Ranges, 80 W, Double-wide
N6785A
Source Measure Unit
The N6785A is a source/measure unit (SMU) designed specifically for battery drain analysis of large mobile, battery-powered devices up to 20 V, up to 8 A, up to 80 W.
-
Product
Digital Source Capture Unit
DIO2
Capture Unit
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
Product
Micro Power or Micro Coax, SIM Insert, ITA, 26 GHz, 2 POS, 6 Slot (not loaded)
510181110
SIM Insert
Micro Power or Micro Coax, SIM Insert, ITA, 26 GHz, 2 POS, 6 Slot (not loaded)Micro Power or Micro Coax patchcords need to be purchased separately.
-
Product
4x 3U OpenVPX MOSA Data Concentrator Unit
SIU34-DCUVARM-01
Data Concentrator Unit
SIU34-DCUVARM-01 is a Modular Open Systems Approach (MOSA) DO-178C & DO-254 Certifiable Data Concentrator Unit (DCU) with low power high performance OpenVPX Xilinx UltraScale+ SBC with Quad Core ARM Cortex -A53, 8 GB DDR4 SDRAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet, USB 3.0, FIPS-140-3 Level 3 Cyber Security, and Single Event Upset support.
-
Product
PXIe-4140, 4-Channel Source Measure Unit
781742-01
Source Measure Unit
The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
Blank Insert Kit, Receiver/ITA, SIM, VTAC, 10 Pieces
610151102
Insert Kit
Blank inserts are for unused VTAC module slots. One blank insert fills 1 slot in a VTAC insert-compatible module.
-
Product
PXI Based Multifunction Measurement and ICT Instrument
PXI-501
Multifunction Switch/Measure Unit
The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
Fault Insertion Unit
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
Source Measurement Unit
SMU4
Source Measure Unit
The SMU4 offers high voltage DPS in a compact, 3U PXI form factor. The SMU4 supports -20V to +20V 100mA with FVMI, FVMV, FIMV, FIMI modes.
-
Product
USB Modular Source Measure Unit
U2723A
Source Measure Unit
The 3-channel 20V/120mA module can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit
782856-02
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.





























