Synchronization Modules
-
Product
PXI/PXIe RF Switch, Hex SPDT, 3GHz, 50Ω, MCX
40-870A-106
Switch Module
The 40-870A-106 (PXI) and 42-870A-106 (PXIe) are 50Ω RF switches with 6 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40/42-870A has been minimized by careful attention to the mechanical and electrical design.
-
Product
PXI Remote Mount Dual SP6T Multiplexer 18GHz 50, SMA, Terminated
40-785B-522-TE
Multiplexer Module
The 40-785B-522-TE is a remote mount dual 6-channel 18GHz terminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
Zynq Ultrascale+ MPSoC (ZU19/17/11EG) 3U-VPX Plug-in Module
iW-RainboW-G35V®
FPGA Module
AMD Xilinx’s ZU19/17/11EG Zynq Ultrascale+ MPSoC64bit, 8GB PS DDR4 RAM with ECC (Upgradable)Dual 64 bit, 8GB PL DDR4 RAM (Upgradable)8GB eMMC Flash (Upgradable)3U VPX Connectors based on ANSI/VITA 46.30 (P0+P1A & P1B+P2A)8 Optical transceivers through MT Ferrule Connector (P2B) based on VITA66.4
-
Product
Mini Power, Module, ITA, 90 Series, 19 Position
510108115
ITA Module
These mini power modules can withstand temperatures up to 140 °C. The faces of the power modules are screened with a red strip to indicate power.
-
Product
PXI/PXIe High Voltage Multiplexer, Hex 7-Channel, 2-Pole
40-321-123-HI
Multiplexer Module
The 40-321-123-HI (PXI) and 42-321-123-HI (PXIe) are hex 7-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 26.5 GHz, 50 Ω, SMA, Failsafe, Remote Mount
42-782B-532-E
Switch Module
The 40-782B-532-E (PXI) and 42-782B-532-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 26.5 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
LXI Microwave Multiplexer, SP6T, 8-Bank, 26.5GHz, 50Ω, SMA
60-800-308
Multiplexer Module
Our 60-800-308 is a 8 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI Very High Density Versatile 2-Pole MUX
40-613-002
Multiplexer Module
The 40-613 Very High Density Versatile 2-pole Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 26.5 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-785C-532-E
Multiplexer Module
The 40-785C-532-E (PXI) and 42-785C-532-E (PXIe) are dual failsafe SP6T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI 2A Multiplexer, 4-Bank, 4-Channel, 8-Pole
40-614B-009
Multiplexer Module
This 4-bank, 4-channel, 8-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 16-Channel, 8-Pole
40-614D-018
Multiplexer Module
The 40-614D-018 (PXI) and 42-614D-018 (PXIe) 1-bank, 16-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 3GHz, 50Ω, N-Type, Terminated
40-785C-561-T
Multiplexer Module
The 40-785C-561-T (PXI) and 42-785C-561-T (PXIe) are single SP6T 3GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 50GHz, 50Ω, SMA-2.4
40-785C-552-T
Multiplexer Module
The 40-785C-552-T (PXI) and 42-785C-552-T (PXIe) are dual SP6T 50GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
778572-14
Signal Module
7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI Multiplexer Single 32 Ch 2 Pole
40-630-022-32/2
Multiplexer Module
The 40-630 series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.Each module is configured into one of the configuration modes. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole and 1-pole screened.
-
Product
PXI/PXIe RF Switch, 8xSP4T + 4xSP4T, 1.3 GHz, 50 Ω, Multiway Connectors
42-755A-902
Switch Module
The 40-755A-902 (PXI) and 42-755A-902 (PXIe) are high density RF switch modules configured as 8xSP4T and 4xSPDT. The range of modules is available in 50 Ω and 75 Ω variants with mixed SP4T & SPDT switches in a single PXI module. They are available with two connector options; SMB that provides a frequency range of 1.8 GHz (50 Ω) / 1.3 GHz (75 Ω), or multiway which limits the bandwidth to 1.3 GHz but offers a high density solution occupying one PXI slot. The connectors used are fully supported by the range of Pickering Interfaces connection solutions.
-
Product
PXI/PXIe MEMS RF Multiplexer, Dual 4-Channel, 4GHz, 50Ω, SMB
40-878-221
Multiplexer Module
The module is based on the latest micro-electromechanical system (MEMS) switching technology and has low insertion loss and VSWR. In addition, MEMS devices have a long operational life of >3 billion operations and benefit from an operating time of <20 μs allowing greater test system throughput. The multiplexers have excellent and repeatable RF characteristics beyond 4 GHz with each path having a nominally equal insertion loss.
-
Product
PXI/PXIe MEMS Optical Switch, Single Insert/Bypass
40-860A-512-M
Multiplexer Module
The 40/42-860A-512-M is a PXI/PXIe single insert/bypass switch with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI 2A Multiplexer, 1-Bank, 128-Channel, 1-Pole
40-614C-015
Multiplexer Module
This 1-bank, 128-channel, 1 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 40GHz, 50Ω, SMA-2.9, Remote Mount
40-784B-042-E
Multiplexer Module
The 40-784B-042-E (PXI) and 42-784B-042-E (PXIe) are dual SP6T 40GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
42-321-109-HI
Multiplexer Module
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI Replacement Microwave Multiplexer Relay
40-785-751-R
Multiplexer Module
Pickering Interfaces PXI Microwave multiplexer modules are suitable for switching 50Ω signals up to 40GHz. The 40-785 is available as a single or dual 6 channel multiplexer, with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber, FC/APC Connectors
40-850A-014
Multiplexer Module
The 40/42-850A-014 is a PXI/PXIe 4-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
LXI Microwave Multiplexer, SP4T, 4-Bank, 50GHz, 50Ω, SMA-2.4
60-803-604
Multiplexer Module
Our 60-803-604 is a 4 bank SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 16 banks of 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Coax, Module, Receiver, 75 Ohm, 90 Series, 32 Position
510104249
Receiver Module
Primary mating module 510108179. (May mate with other ITA modules, as well.) *Please note: VPC receiver modules must be separated into two pieces in order to extract contacts. For detailed instructions please consult the user manual/procedure sheet for this module before extracting contacts.
-
Product
20 Channel Actuator/GP Switch Module for 34970A/34972A
34903A
Switch Module
The Keysight 34903A is a general-purpose switch module for the 34970A/34972A Data Acquisition/Switch Unit. It has 20 independent single-pole, double-throw (SPDT) relays and is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. Combine it with matrix and multiplexer modules to build custom switch systems. Its 300 V, 1 A contacts can handle up to 50 W, enough for many power line switching applications.
-
Product
Quad 4-Channel 1-Pole 16 Amp PXI Power Multiplexer
40-662-001
Multiplexer Module
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-784B-042-E
Multiplexer Module
The 40-784B-042-E (PXI) and 42-784B-042-E (PXIe) are dual failsafe SP6T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-785C-541-E
Multiplexer Module
The 40-785C-541-E (PXI) and 42-785C-541-E (PXIe) are single failsafe SP6T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Breadboard Module, 2-Slot, 37-Pin D-Type
40-220A-202
Signal Module
The 40-220A series of breadboard modules allow the user to construct their own circuit in situations where a suitable PXI module is not available. For example when it is required to integrate a non-switching function into a PXI chassis. Typical applications include: Creating custom circuitry that can be housed in on a 3U board, or to build special one-off switching modules.