Line Fault Indicators
See Also: Overhead Line
-
Product
Cable Fault Locator ECFL 30
ECFL 30
-
Compact precision active/passive, AC/DC bridge with dual channelTDR for fault location on balanced loaded and unloaded cables.
-
Product
Ground Fault Locator
GFL-1000
-
The GFL-1000 ground fault locator is used to pinpoint faulty grounding where electrical cables have breakage and lost to the ground. The GFL-1000 is recommended by NERC PRC-005-2 to inspect for unintentional grounds for VLA, VRLA and NiCad batteries every four calendar months. Included software allows for data management analysis.
-
Product
Classic Collet | Gray | With Line | Matt Or Glossy | Ø 36 Mm
021-6x10/5
-
Secure plastic mounting cap for collet or wing knob
-
Product
Single-in-Line Reed Relays
Series 112
-
SIL relays - 0.15 inch wide x 0.4 inch long package.Pins on 0.1 inch pitch - Compatible with Pickering Series 110 & 111
-
Product
Line Scan Camera
Linea
-
Introducing Linea, a CMOS line scan camera that can help you improve your imaging and lower your costs. Linea starts with an advanced CMOS sensor with high quantum efficiency and low noise for better images. Linea is also packed with advanced features to make your machine vision job almost effortless.
-
Product
RS-232 Micro Line Driver - DB9 Connector
Model 209
-
FEATURES: Compatible with PC; 386/486 Pentium Com Ports; Full Duplex to 19.2 KBPS; No AC or DC Power; Screw Terminals or RJ-11; Small Size. The Model 209F offers all the features of the Model 201 Short Haul Modem but in a package that is approximately one third the volume.
-
Product
Fault Locating
-
Schweitzer Engineering Laboratories, Inc.
The built-in fault-locating methods in SEL devices allow you to quickly identify faults, dispatch crews for repairs, and restore service faster. Traveling-wave fault-locating technology calculates the locations of temporary and permanent faults by measuring the arrival times of the naturally occurring traveling waves caused by a transmission line fault. Accurately detecting these waves requires ultra-high-resolution monitoring, and locating is accurate to within one tower span (±300 m). Impedance-based fault-locating technology calculates fault locations by detecting changes in line impedance as a result of a fault. Impedance-based locating is reliable and accurate to about 2 percent of a line’s total length.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
42-204-001
Multiplexer Module
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Product
Intermittent Fault Detection & Isolation System
IFDIS
-
The IFDIS™ uses patented Intermittent Fault Detector technology that simultaneously and continuously monitors every circuit path within a Unit Under Test (UUT) - such as a Line Replaceable Unit (LRU) chassis' interconnects - for intermittent continuity failures that occur for as short as 50 nanoseconds. This state of the art technology is combined with an environmental chamber and vibration table, which simulate the UUT’s operational environment and cause intermittent faults to manifest, creating a system that is unsurpassed in intermittent fault detection.
-
Product
Ground Fault Detectors
-
STB Electrical Test Equipment, Inc
STB's convenient Ground Fault Detectors may be operated with one hand and are ideal for preventative maintenance. Ground Fault Detectors indicate ground faults and electrical leakage while equipment is in operation.
-
Product
Economic Type Frequency Indicator
CS1-RL
-
CS1-F economic type Frequency Indicator has been designed with high accuracy measurement, display and communication of Frequency.The innovation feature is auto-range input from 0.01Hz~ 100KHz (option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of panels and testing applications.
-
Product
Phase Sequence Indicators (Contact Type)
ST-850
-
Standard Electric Works Co., Ltd
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
-
Product
Customized Indicator Cluster Gauge Kits
169CL-series
-
Over the past 40 years, Sigma Tek has custom designed and manufactured reliable, proven instruments for virtually every type of aircraft that flies. This includes precision modular instrumentation configured to customer's exact specifications. Cluster modules measure 1.44" square, and can be arranged in almost any combination for optimum panel utilization. Individual modules are easily removed for calibration and service.
-
Product
Transmission Lines
-
SemiGens 50-ohm Transmission Lines offer the RF/microwave designer complete flexibility and repeatability for the most challenging applications.
-
Product
Power Cable Fault Locator
TM500
-
TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.
-
Product
Vector Network Analyzer 9KHz-3.2GHz. Includes Adv Meas Kit, Distance To Fault Opt, Cal and Utl Kits
T3VNA3200
Vector Network Analyzer
Vector Network Analyzer 9KHz-3.2GHz. Includes Adv Meas Kit, Distance To Fault Opt, Cal and Utl Kits.
-
Product
Non-Contact Type Phase Sequence Indicator
895 PR
-
Standard Electric Works Co., Ltd
Protection class: IP40. Non-contact detector clips. No metal contact points to advocate greater safety. Two functions in one unit : open phase and phase sequence detection. Designed for checking a wider range of 3-phase power sources. LED display lights with buzzer indicator. Brightness button feature for better visibility in dimly lit areas or sunlight. Magnetic mounting feature.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
Multiplexer Module
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
Phase Rotation Indicator
9040
-
The Fluke 9040 is effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. The Fluke 9040 is a rotary field indicator and can provide clear indication of the 3 phase via an LCD display and the phase rotation direction to determine correct connections.
-
Product
OLP - Optical Line Protection
-
Nanning Xionghua Photonics Technology
OLP - Optical Line Protection by Xionghua Photonics
-
Product
4 Port Phone Line Simulator (FXS) Adv
SIM-4FXS-A
-
This unit has 4 analog phone lines (FXS) making it a perfect tool for testing VoIP gateways, IVR, modems, access servers, audio conference equipment or anything that requires phone lines. Telephone line simulator acts like a "telephone company in a box" providing dial tone, ring voltage and all advanced phone line features such Caller ID, Call Waiting, Call Hold, Three Way Calling and many others.
-
Product
Programmable Selsyn Indicators
PSI
-
Computer Conversions Corporation
Computer Conversions Solid State Selsyn/Resolver Indicator digitizes the outputs of Selsyns, Synchros and Resolvers for position indication and control applications. The Selsyn Indicator is designed to replace failure prone mechanical selsyn torque receivers, counters, etc. The tracking converters high noise immunity and high speed tracking characteristics make it ideal for use in industrial envrionments.
-
Product
Solar Turnkey Lines
-
Ecoprogetti offers complete solar turnkey lines for the manufacturing of photovoltaic modules. According to the customer's needs we customize the line in order to always give the best solutions.
-
Product
Bleeder, Pressure Indicator - Brake, F/A-18 Hornet
-
F-18 Brake Bleeder. This unit is designed to test, monitor and bleed the brake systems of F/A-18 Hornet fighter aircraft.
-
Product
Chassis DSUB Trigger Breakout Cable to 6 BNC for PFI 0-3, Remote Inhibit, & Fault, 20 cm
149055-0R2
-
Chassis DSUB Trigger Breakout Cable to 6 BNC for PFI 0-3, Remote Inhibit, & Fault, 20 cm
-
Product
Flap Position Indicators
-
Shows the aircraft flaps positions. It is an internally lighted, dual, self-synchronous, remote reading indicator that has two concentric pointers.
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel
40-200-004
CAN Interface
Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
Classic Collet | Black | Without Line | Matt Or Glossy | Ø 21 Mm
020-4x20/5
-
Secure plastic mounting cap for collet or wing knob





























