Showing results: 1 - 15 of 29 items found.
-
Schwarzbeck Mess Elektronik
In addition to EMI measurement with LISNs (Line Impedance Stabilisation Networks, Artificial Mains Networks), Probes are used for Terminal or Line voltage measurement.LISNs are required to feed the Equipment under Test (EuT) with mains power, to reduce external line interference, to offer the EuT a standardized impedance and to route the extracted r.-f. voltage to the EMI receiver.
-
TDK RF Solutions Inc.
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
SY2036 -
Lisun Electronics Inc.
SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)
-
AFJ Instruments
AFJ FFT 3010 & 3030 EMI Receivers have been especially designed for conducted emission measurement, both during EUT diagnostic development and for final compliance testing.
-
CDN 3043 Series -
Teseq AG
- Compliant with IEC 61000-4-4 & 5- Universal teminals- no special plugs required- Safety HV plugs and terminals-Manual/programmable EUT power ON/OFF control- Short term overstress capability
-
SESD 216 -
Schlöder GmbH
The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods
-
SESD 230 -
Schlöder GmbH
The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods
-
GEOMehanika-M -
ViTec Co. Ltd
The developed measuring complex for testing soils with "GEOMECHANIKA-M" stamps includes:Control and registration unit: measuring station based on NI cRIO equipment, MIDA overpressure sensor, wireless access point AWK-3131-EU-T, pneumatic system based on pneumatics CamozziLinear motion sensorsWireless Operator Console TestSet of connecting cables
-
AXOS5 -
Laplace Instruments Ltd.
The AXOS5 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS5 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
AXOS8 -
Laplace Instruments Ltd.
The AXOS8 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS8 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
Z-Axis Europe
Test fixture is a device designed to mount a device under test (DUT), equipment under test (EUT) and unit under test (UUT) in place and allow it to be tested by being subjected to controlled electronic test signals and procedures.
-
EMCTEST
Helmholtz coils is a candidate test apparatus for low frequency magnetic field susceptibility testing on military equipment and subsystems. Use of this coils reduce electromagnetic compatibility (EMC) qualification tests time, and subject the equipment under test (EUT) to a relatively uniform field.
-
Keystone Compliance
Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves immersing the equipment under test (EUT), in water. These tests are numbered IPX7 and IPX8. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the immersion ingress protection test, would always be a 7 or an 8.
-
Keystone Compliance
Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves exposing the equipment under test (EUT), to high-pressure and high-temperature water jets. These tests are numbered IPX9. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the high-pressure and high temperature water jets ingress protection test, would always be a 9.
-
AdVISE -
Rohde & Schwarz GmbH & Co. KG
R&S®AdVISE visual inspection software automates the process of visually monitoring an equipment under test (EUT) during a test sequence. This eliminates human inattention, ensures reproducible results and simplifies the test documentation. A typical application is EMS testing with R&S®EMC32 and R&S®ELEKTRA test software.