product
ITA, i2 MX, EMI, High Speed, XL Backshell (XL Bend Radius and Cable Exit)
410130133
This model i2 MX includes VTAC high speed rail inserts making it compatible with VPC wired SIM ITA inserts. The XL-size backshell allows for a greater cable bend radius and large cable exit which accommodates larger, high speed cables. The max cable bundle eff diameter= 1.67".
-
product
Vector Network Analyzers
ZND
The R&S®ZND network analyzer performs unidirectional measurements up to 4.5 GHz in the base model. It can be expanded to perform bidirectional measurements and the frequency range can be extended to 8.5 GHz. The large R&S®ZND touchscreen is easy to operate making it ideal for S-parameter measurements, even when many diagrams are needed. Time domain measurements can also be added for even more functions.
-
product
Three-Phase compact Electric Power/Energy
MC133C
The Model MC133C is a compact single housed three phase electric power/energy calibrator. It can supply the device under test with precision one phase AC voltage and current with calibrated phase shift along with DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
product
Single Channel Potentiostats
VersaSTAT Series
This family of instruments combines our option-based hardware and software platforms to create the most popular line of potentiostats. Introduced for the majority of researchers doing typical electrochemical experiments, this entire series gained a key improvement in 2018. As of August 1st, 2018, all VersaSTAT models have ± 2 Amp capability standard. Users can now study larger samples at faster rates.
-
product
Modular Display Unit
AN-6150
The Model AN-6150 is a compact, cellular display unit which allows a wide variety of customer configurations. Any combination of four standard window sizes can be accommodated in each cell. These cells can be configured in any matrix up to 6 high and 6 wide. The single module is designed to DIN 2.84" x 5.67" standard.
-
product
Turnkey or PCI Cards and Software
WinCAT Systems
# True fast transient recorder system.# 4, 8 or 16 channel models.# 1 MHZ aggregate 12 bit sampling, resolution equal to 0.024% of full scale.# 13 record lengths, user selected, 132 msec to 1,320 sec in typical 1-2-5x scope progression.# 6 programmable front end gains, user selected, equal to 0.4, 1, 2, 4, 10 and 20 volts full scale.# Software converts digitized voltages to Engineering units.# Digital Triggering, Amplitude and slope, in engineering units from digitized input signals.
-
product
Indentor Extension Tester for Types A and D
Applicable standards specify two extensions for an indentor, 2.50mm and 2.54mm, and the indentor testers are available for two models A and JA corresponding to the respective extension. Each indentor extension tester set is complete with two gauges, one for hardness value of 50 and the other for hardness value of 2.
-
product
InfiniiVision Oscilloscopes
6000 X-Series
1 GHz to 6 GHz, DSO or MSO models See more signal detail with 450,000 wfms/s update rate Isolate signals in seconds with exclusive Zone Touch Triggering Operate hands-free with multi-language voice control Get more functionality with optional integrated digital channels, serial protocol analysis, dual-channel WaveGen and 10-digit counter + 3-digit voltmeter Protect your investment with full upgradability; add options and bandwidth at any time
-
product
RF Couplers
Directional, bi-directional, dual-directional and RF Taps; over 475 models with power handling from 0.5 to 300W covering DC to 65 GHz!
-
product
PCI Express Full Tx Test Suite
SW02PCIE
The PCI Express Full Tx Test Suite is part of the subscription based Oscilloscope Compliance Test Software Suites. In addition to Tx Validation licenses for PCIExpress, this suite also provides the support of the Advanced PCIe Protocol Decode/Trigger Software. This suite supports coverage across the PCI Express technology starting from Gen4. Together with the subscription model, this enables the support and coverage continuity as the PCI Express technology progresses through generations.
-
product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
PXIe-4154, 2-Channel, 8 V, 3 A PXI Programmable Power Supply
781155-01
2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.
-
product
3D Inspection Service
The reference data may come in the form of a table, with values at specific points or features, a cad model, or 3d scan. 3D inspection services may require datum measurements, where the part to be inspected is located in a fixture that is specifically designed to orient the part by an ordered method. In some cases, the part may have features that are designed specifically to be referenced by datums, if no functional feature of the part provides a clear reference.
-
product
PM Mass Monitor
Model T640
Teledyne Advanced Pollution Instrumentation
The Model T640 PM Mass Monitor is the next breakthrough in ambient particulate monitors. The T640 delivers 1-min or better time resolution with exceptional sensitivity and precision. The instrument is very low maintenance and requires no sample media for minimal cost of operation.
-
product
Insulation Resistance Tester For PV
MSEI-200C
MULTI MEASURING INSTRUMENTS Co., Ltd.
This model can measure insulation resistance of DC current circuit in PV systems (between PV module and power conditioner) on the live line and can distinguish the deteriorated part between Power Phase, Neutral Phase, P/N Phase and or PV modules.
-
product
Singlebeam Hydrographic Echosounders
Teledyne Marine Odom Hydrographic
Odom Hydrographic provides an extensive range of hydrographic level single beam echosounders with the flexibility of frequency agility supporting existing transducer installations. Models include modern PC screen based interfaces as well as support for tried and tested thermal record printing.
-
product
Peak/Average Reading Broadband, Multirange Directional RF Wattmeter
83060
Similar in appearance and operation to our standard Model 81060 Wattmeter, the Model 83060 converts from Average Reading to Peak Reading, with the flip of a switch, by inserting a peak reading amplifier between the element and the meter
-
product
Low Cost Solar Simulators
Abet Technologies model 10500 is a low cost solar simulator providing an attractive alternative to more fully featured and expensive solar simulators for applications that do not require a large area illuminated field. The optical system of the 10500 produces a collimated 25 mm beam. Focus or defocus it for higher irradiance or larger solar cells. One sun output is achievable up to a 35 mm diameter illuminated field.
-
product
Field Strength Meter
FIM-71 VHF
The Model FIM-71 is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-71 is suitable for practically all types of RF emission measurements in the 45 MHz to 225 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and a meter dynamic range of either 20 dB or 60 dB. A dc analog output voltage, proportional to the meter indication, is provided for driving a chart recorder. A leveled output from the calibrating oscillator is available for measuring cable insertion loss, filter response, amplifier gain, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.
-
product
Switch Mode Power Supplies-Water Cooled
The MSW Rectifiers are based on Switch Mode Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%.The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
product
PXIe Vector Network Analyzer, 300 kHz to 9 GHz
M9372A
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
BNC To BNC Cable, 50 Ohm, 0.9 M
781887-01
Connects measurement and signal generation devices. Model options include industry-standard coaxial connector types including BNC, SMA, SMB, and MCX. Long cables can act as antennae picking up extra noise that can affect measurements, so ensure you select only the length required for your test system. Also look at the impedance of your test system and consider buying a cable with the same impedance. Matched impedance can maximize the power transfer or minimize signal reflection from the load of your system.
-
product
Curve Tracer
CS-3000 Series
CS-3300 / CS-3200 / CS-3100 three model line-up. Maximum peak voltage: 3,000V (high-voltage mode for all models) in CS-3000 Series.Maximum peak current: 1,000A (CS-3300 high-current mode). The CS-3000 Series are CE-marked and UL listed.
-
product
Fluxmeter
480
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined.
-
product
Temperature Controlled Air Bath
9300A
Measurements International Ltd.
The model 9300A series of Temperature Controlled Chambers is designed as a convenient and inexpensive way to maintain the temperature of air resistors in the calibration laboratory. It is large enough to house several standard air resistors and features two adjustable shelves to permit easy access to the standards. The shelves are easily removable.
-
product
Handheld Durometers
EX Series
The EX Series durometer is available in Shore A, Shore D and Asker C hardness scales with an accuracy of ± 1 point.The X Series durometer is available in Shore A, Shore D, Asker C, and Asker F hardness scales with an accuracy of ±0.75 points. The X Series also offers a model with a long presser foot for small or recessed areas.Both durometers are available with an optional peak indicator.
-
product
NanoSpectralyzer
NS2
NS2 is the world's only three-in-one spectrometer for carbon nanotubes. The NS2 provides all of model NS1's state-of-the-art capabilities for analyzing SWCNT samples through near-IR fluorescence and absorption. In addition, the NS2 captures Raman spectra of all CNTs, whether single-walled, multi-walled aggregated, large diameter, or chemically altered. All spectra are automatically measured with a single placement of the sample cuvette. Sophisticated software then performs integrated data analysis to characterize the CNT sample.
-
product
Control Room Oxygen Monitor
Model 3350
Teledyne Analytical Instruments
The Model 3350 accurately measures the concentration of oxygen in control rooms, closed atmospheres, critical breathing circuits and other applications that require the fail-safe monitoring of breathable, ambient air. It is a microprocessor-based oxygen alarm monitor for real-time measurement of the oxygen content of the atmosphere surrounding the sensor as well as shoulders the burden of personal safety with the quality and reliability offered by the Teledyne name.
-
product
General Inclinometers
Columbia Research Laboratories
Columbia's SI-701 Series of Inclinometers are electronic tilt sensors based on Force Balance Accelerometer technology. They produce high level low impedance output proportional to the sine of the tilt angle. Model SI-701B is a low cost general purpose sensor that can be up-graded with the addition of the Columbia "HP" torquer system (SI-701BI) for greater accuracy and ruggedness. A bi-axial version of both units (SI-702B) is also available. The Model SI-701BI is designed with an output circuit made for 4-20mA data transmission systems for industrial applications. The model SI-701FND is a fluid dampened premium performance inclinometer designed to produce accurate tilt data in extreme shock and vibration environments. The latest addition in the line is Model SI-701WPBI, a waterproof (to 150 feet) inclinometer which operates from a +15 volt supply with 4-20mA output. A single power supply powers both the sensor and the 4-20mA line driver.