Cesium Standards
A primary frequency standard in which electronic transitions between the two hyperfine ground states of cesium-133 atoms control the output frequency.
-
Product
Military Timing Solutions
-
Brandywine is AS9100C certified and supports the environmental testing and specific interface standards needed for simple integration within military hardware. Brandywine offers many standard options for our military timing products including cesium frequency standards for international applications as well as the option to customize each product to fit your specific timing needs.
-
Product
Electrical Standards
-
To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.
-
Product
Capacitance Standard
GenRad 1417
-
The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.
-
Product
Cesium Vapour Magnetometer
ENVI Cs
-
The ENVI Cs is a continuous reading magnetometer with high sensitivity with integrated navigational GPS and a versatile design that offers the user the ability to maximize productivity.
-
Product
Capacitance Standard
SCA Series
-
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
Product
Pioneer Standard Cabinet
-
The Pioneer rack is the cornerstone of our broadcast cabinet line, offering flexibility, versatility and strength. Pioneer racks are offered in more than 25 different sizes, creating hundreds of configuration possibilities.
-
Product
Inductance Standard
1482 Series
-
The GenRad 1482 Standard Inductors are the standard of choice in metrology labs. Used today by national metrology institutes and primary standards bodies around the world, these inductors have no peer or equivlent.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Disciplined Frequency Standard
2975AR
-
The 2975AR contains a rubidium timebase and provide one 10 MHz, one 5 MHz and one Signal Generator output. The Signal Generator uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50 MHz using front panel controls or from an RS232 serial interface. The 2975AR can be disciplined by a 1pps input signal and provides a 1pps output signal. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
Product
Standard Magnetizers
-
The selection of a magnetizing system begins with an analysis of the production requirements, including magnet material, magnet size, magnetizing orientation, number of poles, production speed, magnet measuring, and other operations that are necessary. After careful evaluations of these factors, and reviews of samples and/or drawings, our application engineers can recommend a system that will meet your requirements.
-
Product
Automated Temperature Resistance Standard
-
Measurements International Ltd.
Exceptional Stability, Cost-effectiveness, Performance-based Results, 10 Ω, 25 Ω, 100 Ω, 200 Ω, 400 Ω and 1000 Ω Internal Standards, Built-in Temperature Chamber for Optimal Performance.
-
Product
Standard Tests
-
The following list contains only the most important standards and does not claim to be complete.EN 60204-1 Electrical equipment of machinesEN 60335-1 Electrical appliances for household and similar useEN 50106 Sampling test, routine tests (in conjunction with EN 60335-1)EN 60598-1 LuminariesEN 60601-1 Medical electrical equipmentEN 60730-1 Automatic electrical controlsEN 61010-1 Measuring, control and laboratory equipmentEN 61439-1 Switch cabinet and switchgearEN 62368-1 Equipment for audio/video, information and communication technologyEN 62841-1 Hand-held electric toolsEN 50191 Erection and operation of stationary and non-stationary electrical test equipmentLVD Low V oltage D irective _
-
Product
Standard Handheld Display
TW-3.0-S
-
The TW-3.0-S Standard Handheld Display is a modern, slimline, multifunctional load monitoring device which is unique to DLM. This innovative design is built with the user in mind. It has a large, high quality LCD screen which is optically bonded removing the need for a back light and improving clarity in bright sunlight. For ease of use each handheld can be given a customisable friendly name made visible on the screen to make instant identification possible. This multi featured high precision unit ensures reliable load readings while also being simple to operate. It can be used in conjunction with any DLM manufactured load cell, just look for the d+ logo on our products.
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
Standard Directional Gyroscopes
4000B-series
-
The 4000B is our standard air-driven directional gyro. As the aircraft turns left or right, gears on the sensing unit and dial shaft translate this rotation into rotation of the instrument’s vertical dial. Left turns produce clockwise dial rotation and right turns produce counter-clockwise rotation. The gyro is controlled by a heading selector knob located on the lower left of the instrument. Pressing and turning the knob first disengages the dial shaft and then resets the dial to a new heading, which results in a new course indication. Releasing the selector knob re-engages the dial shaft. The on-course position of the pointer is always at the top of the azimuth circle (0° on the dial with the aircraft headed north).
-
Product
Portable Three-Phase Energy Standard
PEWM-3C
-
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
Product
Vehicle Standard Interface
VSI-2534
-
Vehicle reprogramming tools are becoming an essential auto diagnostic tool in automotive repair shops. Technicians often come across OEM Technical Service Bulletins that require them to reprogram the vehicle with the latest OEM calibration files in order to diagnose and repair car problems such as check engine light, gas mileage, false DTCS, shifting, hesitation, rough idle, emissions quality, ABS, performance, and more.
-
Product
NF-Series Standard Models
-
The E-DRIV® NF-Series standard models feature an adjustable RPM setting on the tool and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Standard Type
FD-10
-
This device supports the measurement of rivers, Agricultural water, Sewage systems, Other channels and facilities.
-
Product
Analyse-it Standard Edition
-
The powerful statistical analysis and regression you'd expect from an expensive statistics package.
-
Product
AC Calibration Standard
1U647-001
-
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Standard Digital Isolators
-
Analog Devices’ digital isolators enable designers to implement robust solutions with our magnetically isolated iCoupler products with the flexibility of up to 6 channels. Products meet stringent safety standards including the ability to isolate IS-IS with our intrinsically safe certified digital isolators which enable designs in hazardous areas. And automotive certified versions are also available. Utilizing the iCoupler® and isoPower® technologies, these isolation solutions enable designs without the constraints found in optocouplers.
-
Product
Standard Gain Horns
-
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas
-
Product
Standard Test Devices
-
Zhengzhou SMS Electric Co.,Ltd
Fast, accurate verification to ensure that all devices work reliably.





























