Visual Fault Finders
Apply light to optical fibers, enabling visual inspection to determine integrity.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
Fault Insertion Unit
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 1-Bus
40-199-001
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Cable Fault Finder
-
Techno Instrumentation (India) Private Limited
Magnetic and Acoustic signal strength through bar graph and digits on LCD.Coincidence feature gives distance to the fault in milliseconds.Easy, fast and accurate pinpointing of faults.
-
Product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
Fault Insertion Unit
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
Fault finder
The STaff™
-
The staff fault finder is designed to meet the demands of the professional troubleshooter but its simplicity and price make it a tool for anyone needing to locate cable faults. Arrows on the LCD screen direct the user to the fault with pinpoint accuracy. A reference indication also will aid the user in identifying multiple faults when present. Whether you are fault locating utility service line or locating a broken sprinkler wire, the STAFF is the professional's choice.
-
Product
650nm Visual Fault Locator
-
Shanghai Baudcom Communication Device Co.,Ltd.
Visual Fault Locator series Visual Fault Locator uses the DFB-LD as the emitting component. Driven by constant current source, the indicator can emit stable red laser.The product can be used to inspect fiber failure when they connect with optical interface and be inserted into single mode or multi mode optical fiber.It is indispensable tool in fiber project constructing, fiber net-work maintaining, optical component manufacture and research.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
Visual Fault Locators
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
Joinwit Visual Fault Locators
-
Product
Visual Fault Locators
MVFL Series
-
Shanghai Tarluz Telecom Tech Co., LTD
MVFL series Visual Fault Locators is meet the Class IIIA product, which is the easiest way to identify fibers from end to end and locate polished connector endfaces. Its red laser shines through most yellow-jacketed fibers to help you pinpoint breaks, bends, faulty connectors, splices and other causes of signal loss. The 1mW output power enable the MVFL has a reach of up to 5 km. MVFL seires VFL locates faults visually by creating a bright red glow at the exact location of the fault on single mode (SM) or multimode (MM) fibers. Due to its small size, lightweight and simple but proven design, the MVFL can accompany you anywhere In your pocket or belt pouch in harsh environment
-
Product
Visual Fault Locator
-
Shanghai Baudcom Communication Device Co.,Ltd.
This Pen-type VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical networks. It finds breakpoints, poor connections, bending or cracking in fiber optic cables
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
Visual Fault Locator
FFL-210-U
-
FFL-210-U Visual Fault Locator is equipped with a 650 nm high power visible laser diode,can be operated in CW (continuous) or MOD (1Hz modulation) mode. There are two LED indicators:RED & GREEN; the RED one shows the operating mode of the Laser Diode output signal, and the GREEN one indicates low battery level. FFL-210-U is housed in a pocket-size, rugged metal casing, comes with a carrying pouch.
-
Product
Visual Fault Locators
-
Optical Wavelength Laboratories
OWL fiber optic visual fault locators (VFL) are specially designed to couple a maximum of optical energy into multimode and singlemode optical fibers by using a bright red fiber optic laser. Breaks, microbends, and other anomalies in optical fibers and connectors cause the intense bright red laser light to escape, thus revealing the presence of a fault. In addition to visual fault location, OWL VFLs can be used as a visual optical fiber identifier. A visual fiber optic identifier eliminates much of the guesswork during testing by identifying the fiber under test.
-
Product
Handheld Visual Fault Locator(VFL)
JW3105N
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3105N Economical VFL is an efficient and low cost basic fiber test tool, it provides a visible way to find fiber faults and identify fibers in an optical network during and after installation.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Visual Fault Locators
-
Visual fault locators are used to identify problems with your fiber. GAOTek visual fault locators typically are applied for fiber tracing, fiber routine, and continuity checking. Imagine being able to easily identify when and where a fiber is breaking, bending, or when there’s a threat to the fiber layer.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Visual Fault Diagnostics and Repair System
ScanExpress Viewer
-
ScanExpress Viewer™ is a printed circuit board (PCB) CAD data & photograph visualization tool for boundary-scan test development, electronic manufacturing test, and product repair environments.When combined with ScanExpress ADO™ (Advanced Diagnostics Option) for detailed results from ScanExpress Runner™, ScanExpress Viewer displays fault coordinates and connected traces superimposed directly on a board photograph or CAD layout diagram for expedient repair.
-
Product
Platinum Tools Fiber Optic Visual Fault Locator
#TVFL100
-
Fiber optic visual fault locator works with virtually all 1.25mm and 25mm fiber optic sizes and connector types.
-
Product
Fault Finder and Cable Length Measurement TDR
Snap Shot™
-
Accurately finds cable length, impediments in the cable and conditions at the end of every wire in your data, power, or communications/video system up to 3,000 ft.
-
Product
Visual Fault Locator
FFL-310-U
-
FFL-310-U Visual Fault Locator is equipped with a 650 nm high power visible laser diode,can be operated in -CW (continuous) or … MOD (1Hz modulation) mode. There is one LED indicator:with RED or GREEN light; the RED one shows the operating mode of the laser diode output signal, and the GREEN one indicates low battery level. FFL-310-U is designed in a card-size dimensions.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.