Showing results: 8356 - 8370 of 14433 items found.
-
1154 TMF-M -
Standard Electric Works Co., Ltd
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● BS 16 edition.
-
93-016-103 -
Pickering Interfaces Ltd.
93-016-103 eBIRST Termination Fixture is part of a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
93-019-104 -
Pickering Interfaces Ltd.
93-019-104 eBIRST Termination Fixture is part of a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
CMS 356 -
OMICRON electronics
The CMS 356 is a voltage and current amplifier for analog low-level signals provided by a CMC test set or by any other signal source, such as a digital real-time power system network simulator. When used in combination with a CMC test set, the amplifier extends the capabilities of the test set to provide additional output channels and higher amplitudes.
-
Computec SRL
- Laboratory of electrical tests and measurements- Injection of voltages and currents. - Megger SMRT33 Triphasic Case- Protection relay test- Tests with class 0.2 instruments - Fluke N5K 3PP50IP Norma 5000 High Precision Power Analyzer- Verification of energy meters- Fault Recorder Verification- Verification of Power Quality Analyzers- GPS verification
-
SG3004-12(14) -
Shanghai Jiuzhi Electric Co., Ltd.
High voltage impulse test is used to assess the quality of any high voltage equipment. The test object is subjected to a fast voltage impulse of defined wave shape caused by the test object are used for detection of insulation strengths and/or faults. It is commonly used for routine testing of transformer, bushings or other high voltage equipment.
-
HopeTech
insulation resistance tester is an instrument for measuring the insulation resistance of components and equipment. Using constant voltage test method, the voltage output range is 25 ~ 1000V, and the maximum output current is 1.8mA. It also has contact anomaly detection function and short circuit anomaly test function, the fastest test time is up to 50mS.
-
PCMT20 -
Pyle Audio Inc.
Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit
-
T3AFG Series -
Teledyne LeCroy
Teledyne Test Tools new T3AFG series of function / arbitrary waveform generators use advanced Digital Frequency Synthesis (DDS) technology to produce high quality standard function and arbitrary waveform signals. They also provide a wide range of analog and digital modulation functions. The T3AFG series of Arbitrary Waveform Generators includes models with up to 120 MHz bandwidth, 1.2 GSa/s sample rate, 16-bit vertical resolution and 8 Mpts of data. Common analog and digital modulations, sweep and burst are provided to support complex signal generation. The T3AFG series also provides true dual channels with internal waveform combination, flexible phase/channel control and copy/coupling/tracking between channels. These features enable Teledyne Test Tools Arbitrary Waveform Generators to provide a variety of high fidelity and low jitter signals, meeting the growing requirements of complex and intensive applications.
-
72-1015 CAL -
Tenma
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
72-1015 CAL D -
Tenma
The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
72-1015 CAL DU -
Tenma
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Marposs S.p.A.
Marposs complements its geometric measurement solutions with solutions for non-destructive testing using eddy current technology.The testing options can be divided in three large groups:Material integrity test, to check for the presence of defects (cracks, porosity, blow holes, inclusions) on the surface and in the layer just below the surface.Material properties test, to check if the thermal cycles (hardening, hardening and tempering, annealing, stress relieving, etc.) have been performed correctly. Material identification checks are done to sort parts with the same geometry but made with different materials.Thread inspection to check if the treading has been carried out and its quality.In addition to the non-destructive checks performed with the eddy currents, we have developed a durometer for the conventional measurement of surface hardness, according to the Rockwell scale (HRC or HRA); which uses a diamond penetrator to measure the hardness of the sample being tested.
-
ZERA GmbH
Our stationary and mobile instrument transformer test systems are used to test current and voltage instrument transformers. Among other things, accuracy testing, demagnetization and insulation testing are possible.
-
ZERA GmbH
All components from this category can be integrated into an existing current transformer test system. When selecting CT test components, both the type of converter to be tested and the required current are important.