PD Calibrators
-
Product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
Mechanical Calibration Kit
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
Calibration Cable
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
Product
Electronic Calibration Module (ECal), 40 GHz, 2.92 Mm, 2-port
N4692D
Electronic Calibration Module
The Keysight N4692D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4692D is a precision 2-port ECal module that supports 2.92 mm connectors up to 40 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4692D is included for securing your ECal module and accessories.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
Mechanical Calibration Kit
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
Electronic Calibration Module
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
Calibration Cable
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electronic Calibration Module (ECal), 67 GHz, 1.85 Mm, 2-Port
N4694D
Electronic Calibration Module
The Keysight N4694D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4694D is a precision 2-port ECal module that supports 1.85 mm connectors up to 67 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4694D is included for securing your ECal module and accessories.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Electronic Calibration Module (ECal), 18 GHz, Type-N, 50 Ohm, 2-port
N4690D
Electronic Calibration Module
The Keysight N4690D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4690D is a precision 2-port ECal module that supports 50-ohm type-N connectors up to 18 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4690D is included for securing your ECal module and accessories.
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
Electronic Calibration Module
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electronic Calibration Module, DC To 9 GHz, 2-Port
N7552A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
Electronic Calibration Module
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
Calibration Kit YAV90MMU
YAVMMUCK
Mechanical Calibration Kit
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
Ambient Temperature CalPod Module, 20 GHz
85530B
Electronic Calibration Module
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards.
-
Product
PDS Harvester Software
-
Teledyne PDS for harversters is designed to the requirements of the dredge operator to carry out their job more efficiently. The operator has a real time overview of the dredger with the top and side views displaying the vessel outline, ladder, and cutter head along with the surveyed depths, design, and dredged depth.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz, Type-N(m), 50 Ohm
85514A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
Electronic Calibration Module
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
Electronic Calibration Module
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
Product
PD Test Systems
-
1. Number of channels: 2/4 electric signal interfaces & 1 EXT interface 2. Sampling frequency: maximum 200MGa/s 3. Sampling precision: 12bit 4. Range: 0.1mV~20V 5. Range switch: 1mV, 2mV, 5mV, 10mV, 20mV, 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V 6. Frequency band range: 1Hz-60MHz 7. Range non-linear error: 5% 8. Range of capacitance for test object: 6pF~250µF 9. Power source mode: internal lithium cell / AC 220V 10. Display: 6.5 inches TFT LCD 11. Resolution: 640×480 12. PV: 4GB 13. Hard disk: 32G stiff disk used for storing the test data
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
PDS Multibeam Survey & Processing/Charting
-
Teledyne PDS for Multibeam Surveys provides the functionality for survey planning, data acquisition, data processing, editing, volume calculations and chart production. This turnkey solution offers the surveyor and helmsman a strong tool to carry out the multibeam survey efficiently. Progress is shown real time in top, profile, and 3D views using a color-coded digital terrain model (DTM). Various filter settings can be applied to the multibeam data online, thus providing real-time data processing. Quality control displays reassure the operators that the data is of the desired quality.
-
Product
Handheld Online PD Detector
PD-SGS
-
Quick identification of PD activities in switchgear and cable accessories. The BAUR PD-SGS handheld online PD detector is used to conduct rapid initial tests for PD activities on live switchgear. Potential weak points are immediately signalled acoustically and numerically.* Initial rapid condition evaluation of switchgear and cable accessories during mains operation* Ideal for quick checks of MV and HV switchgear* Two integrated sensors:TEV sensor records PD on the surfaces of switchgearsAcoustic sensor records PD inside switchgears* Greater safety for test personnel switchgear tested for safety risks before starting work





























