Gold
invaluable naturally occurring material able to withstand corrosion, highly conductive. Also known as: Au
See Also: Precious Metal, Platinum, Au, Gold Test
-
Product
SMT & THRU HOLE LOADED BOARD TEST PROBES
SERIES 33
-
ElectricalMAXIMUM CURRENT:3 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current,20 mOHMS meanMaterials and FinishesPLUNGER: Heat treated berylliumcopper, 24Kt gold plated over nickelBARREL: Nickel silver with preciousmetal clad ID.SPRING: Music wire, silver plated
-
Product
Standard 0.87 (24.70) - 5.40 (153.00) Battery Probe
BIP-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 394Full Travel (mm): 10.00Recommended Travel (mil): 315Recommended Travel (mm): 8.00Overall Length (mil): 1,220Overall Length (mm): 31.00
-
Product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type E, Ø1.50mm, 305gf
K100-E150305-SKAU
Spring Probe
K100 Series, Pitch 100mil, Tip Style E, Tip Diameter Ø1.50mm, Spring force 305gf, Steel with Gold Plating.
-
Product
Extender
3690-2
-
VECTOR Electronics and Technology, Inc.
Contact fingers at the other end of extender card are gold plated provides low insertion force and positive contact with printed circuit boards. Receptacles have double row phosphor bronze contacts with high quality, long life mounted on top of the extender.
-
Product
Rectifier Diodes
-
Chip Diodes from Bourns has emerged that offers the capability to provide a silicon diode with minimal packaging overhead. The small signal 0603, 1005 and 1206 Chip Diodes are lead free with Cu/Ni/Au plated terminations while the other packages (SMA, SMB, SMC, 1408, 1607, 2010, 2419, 8L NSOIC, 16L NSOIC, SOT23, SOT23-6, 16L WSOIC) use 100% Tin terminations. All Bourns® diodes are compatible with lead free manufacturing processes, conforming to many industry and government regulations on lead free components.
-
Product
PCI Adapter for cPCI
PCI2cPCI
-
PCI2cPCI is an adapter familiy used to mount a cPCI device into a PCI connector. PCI2cPCI-32, PCI2cPCI-32-IO, and PCI2cPCI-64 are passive devices with impedance controlled traces interconnecting the Gold Fingers of the PCI edge connector to the press fit cPCI connector. All PCI signals are routed through including power, ground, PCI bus, secondary control signals.
-
Product
Power Supplies
ZPG-1200B
-
80Plus Gold Certified provides typical 87% efficiency at 50% of max load. The ZPG series can give you the power you need at higher efficiency, which means you can use the same power with less energy. Built in QUAD 8-pin PCI-Express graphic card connector offering further upgradability.
-
Product
Circuit Breaker Testing
-
Weshine Electric Manufacturing Co., Ltd
Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.
-
Product
Bonding Tester
PTR1102
-
In wire bonding in semiconductor manufacturing, electrodes are joined using gold wires of several tens of microns. In order to measure the pull (tensile) strength and ball shear (shear) strength of this gold wire, this machine has load detection accuracy and fine positioning accuracy. In addition, for the measurement of high load areas such as die shear strength and solder joint strength, this machine supports measurement in high load areas while maintaining accuracy in low load areas by replacing the sensor part.
-
Product
Standard 1.00 (28.30) - 5.40 (153.00) Battery Probe
BIP-10
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00
-
Product
Kelvin Clip
BU-78K
-
Kelvin Clip, Gold Plated Brass, 10 Amps, 2.3″ Length, 1/2″ Jaw Opening,
-
Product
Signal, Contact, ITA, TriPaddle, 7 Amp, .025" Square Post for Wire Wrap
610110145
Signal Contact (ITA)
Signal, Contact, ITA, TriPaddle, 7 Amp, .025" Square Post for Wire Wrap.Plated in 50µ" gold
-
Product
SMT & THRU HOLE LOADED BOARD TEST PROBES
SERIES 43
-
MechanicalMINIMUM CENTERS: .075 (1.91)FULL TRAVEL: .250 (6.35)WORKING TRAVEL: .167 (4.24)OPERATING LIFE: 1,000,000 cyclesElectricalMAXIMUM CURRENT: 3 amps continuous at working travel, non-inductiveRESISTANCE: At 35 mA test current,30 mOHMS meanMaterials and FinishesPLUNGER: Heat treated beryllium copper or steel hardened to 55-60RC, both 24Kt gold plated over nickelBARREL: Nickel silver with 24Kt gold plated ID and OD over nickelSPRING: Music wire, 24Kt gold plated over nickel
-
Product
Capillary-fill sensors
-
Zimmer and Peacock have launched the world's first capillary fill sensor for the Research and Development market, both academia and industry. We provide these capillary-fill sensors in gold, platinum and carbon.
-
Product
Hybrid Socket
CSP/Ballnest
-
Any grid size available on 0.50mm pitch or larger. ZIF style socket using Aries solderless, gold plated pressure mount Spring Probe. The gold over nickel plated compression spring probes leave very small witness marks on the bottom surface of the device solderballs.
-
Product
Capacitors - Beam Lead
-
Macom Technology Solutions Holdings Inc.
MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss leveraging nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long-term stability.
-
Product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type H, Ø0.80mm, 305gf
K100-H080305-SKAU
Spring Probe
K100 Series, Pitch 100mil, Tip Style H, Tip Diameter Ø0.80mm, Spring force 305gf, Steel with Gold Plating.
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type K, Ø1.50mm, 155gf
K100-K150155-SKAU
Spring Probe
K100 Series, Pitch 100mil, Tip Style K, Tip Diameter Ø1.50mm, Spring force 155gf, Steel with Gold Plating.
-
Product
MANIA TEST PROBE
SERIES 76
-
ElectricalMAXIMUM CURRENT: 3 amps continuousat working travel, non - inductiveRESISTANCE: At 35 mA test current,50 mOHMS meanMaterial and FinishesPLUNGER: Heat treated berylliumcopper, FINISH: -2E / -2P Hard nickel plated-2D / -2E138 24 Kt gold plated,BARREL: Phosphor bronze, nickel platedSPRING: Stainless steel, silver platedPIN: Music wire, hard nickel plated
-
Product
Differential Scanning Calorimeters
MicroCal DSC Range
-
The "Gold Standard" for structural stability analysis of biotherapeutics, biological macromolecules and polymers in solution. Are microcalorimeters are powerful tools which enable characterization of the thermal stability of proteins and other biomolecules, primarily for biopharmaceutical development and manufacture. They are used for general stability studies, for biosimilarity and batch-to-batch comparability assessment, and for the optimization of purification and manufacturing conditions. MicroCal PEAQ-DSC systems are simple to use, requiring little assay development, and no labelling or immobilization.
-
Product
BIP-10 Battery Probes
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00
-
Product
Working Electrodes for Flow Cell
-
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
Product
Signal, Contact, ITA, TriPaddle, 7 Amp, .025" Square Post for Wire Wrap
610110113
Signal Contact (ITA)
Primary mating contact 610110177. (May mate with other Receiver contacts, as well.)Plated with 30µ" gold.
-
Product
Mini Power, Receiver, 50u Gold (22 Amps). 18 AWG Twisted Pair Red/Black (5 Amps). Banana Plug Black, Banana Plug Red, 41"
7-242418000-041
Power Patchcord
Mini Power, Receiver, 50u Gold (22 Amps). 18 AWG Twisted Pair Red/Black (5 Amps). Banana Plug Black, Banana Plug Red, 41"
-
Product
Cross Flow Cell
-
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
Product
Diode Arrays
-
a silicon diode with minimal packaging overhead. The small signal 0603, 1005 and 1206 Chip Diodes are lead free with Cu/Ni/Au plated terminations while the other packages (SMA, SMB, SMC, 1408, 1607, 2010, 2419, 8L NSOIC, 16L NSOIC, SOT23, SOT23-6, 16L WSOIC) use 100 % Tin terminations. All Bourns® diodes are compatible with lead free manufacturing processes, conforming to many industry and government regulations on lead free components.
-
Product
Limiter Diodes
-
The SemiGen SLP7100 series of Limiter Diodes are processed with a high-resistivity epi that have thin intrinsic layers. These devices are typically in the 2 to 20 micron range of epi thickness and can be gold doped to achieve specific performance goals. These diodes are used in passive or active limiter designs in the 100 MHz to 30 GHz frequency ranges. They are ideal for use in high-power applications and can be supplied in chip form or in your choice of packages below.
-
Product
Power Supplies
ZPG - SERIES
-
80Plus Gold Certified provides typical 87% efficiency at 50% of max load. The ZPG series can give you the power you need at higher efficiency, which means you can use the same power with less energy. Built in QUAD 8-pin PCI-Express graphic card connector offering further upgradability.
-
Product
IceMap™
Real Time Ice Thickness Measurement
-
The IceMap real-time display shows the automatically detected bottom of the ice (blue line) in real time. Users can set a minimum thickness warning threshold (gold line). Winter ice roads and bridges are a common transportation link in the northern regions of Canada, Alaska, Europe and Russia. The Sensors & Software IceMap system is designed to measure the ice thickness on these temporary, yet vital, links and ensure the safety of all travelers. The GPR sensor is towed across the ice surface behind a truck or snowmobile and the ice thickness data, displayed in real-time as a cross-sectional image, are sent wirelessly to the operator’s computer.