Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
Output Characteristic Analyzer of Electronic Ballast
UI2002
-
• Measure lamp voltage, lamp current, lamp power, oscillatory frequency, filament current, guided cathode current, and crest factors • Measure changing curves and values of startup lamp voltage, lamp current, filament current, cathode current from 0 to 5 seconds, as well as the pre-heat time • Accuracy: Class 2 • Data and curves printable. All the data and curves can be displayed after being connected with PC
-
Product
Pulse Start Generator for High Pressure Sodium Lamp
LPSG60662
-
The start-up test of the special lights pulse start generator is for lighting class industry such as high pressure sodium, it is according to IEC60662: 2011 and GB/T13259-2005 standard requirements.
-
Product
6 Position Plug Socket Switch Life Tester
CZKS-6
-
It is designed according to terms and conditions of IEC60884-1, IEC60669-1, GB2099.1-2008 and GB16915.1-2003, for life test of plug and socket and switch products of household and similar use appliances. The device can connect with matched load cabinet, in order to conduct a test of electrical life, normal operation and breaking capacity. The equipment provide some clamp, it can test plug and socket production, wall switch, rocker switch, dial plate switch and button switch.
-
Product
Damped Oscillatory Magnetic Field Immunity Tester
DOMF61000-10
-
DOMF61000-10 damped oscillatory magnetic field immunity test system included damped oscillating wave generator and single ring coil, it’s designed for to do damping oscillation magnetic field immunity test and fully meet IEC 61000-4-10, EN61000-4-10 and GB/T 17626.10 standards requirement.
-
Product
Car Accessories Material Burning Tester
ZRS-4H
-
• Test Gas Source: Gas or Liquefied Petroleum Gas (Suggestion: Use good quality gas if possible) • Burner inner diameter: ¢9.5±0.5mm, about 100mm long with air adjusting hole • Height of flame: Can be adjusted from 20 mm to 100 mm according to the standard requirement • Applying time of flame: Burning time can be adjusted from 0 to 99 minutes 99 seconds • Test process: Automatic control • Inner volume: 0.05m³ • Material: Stainless steel or iron plate spray • Power: AC 220V; 50Hz/5A
-
Product
Integrating Sphere
-
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
Product
Integrated Function Tester for Inductance Ballast
UI2001B
-
• Measure input parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components. V range: 10.0~300.0V, A range: 0.010~2.000A, F range: 45~65Hz • Measure output parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components Lamp voltage range: 10.0~450.0V, Lamp current range: 0.010~2.000A • Accuracy: ± (0.4% reading+0.1% range+1 digit) • Can test every kind of curve, print both data & curve • Communication interface available for PC, running under Windows98/2000/XP/Vista
-
Product
Digital CC and CV DC Power Supply
DC3005
-
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and can output costant current or constant voltage. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer’s request.
-
Product
Fast Photo-Electric Tester
LS616S
-
The machine is made up of three main parts: measuring circuit of electric parameter, measuring circuit of photometric parameter and circuit of CPU system. Voltage and current signals are amplify and sent to high speed A/D transform, and the transform digital signals are sent to microprocessor, the input current signals of brightness detector are sent to A/D transform via I/V convert, and the transform digital signals are sent to microprocessor. Microprocessor processing the input photometric and electric data, it automatic switch between different range and calculate and display the data in the mean time.
-
Product
Lamp Cap Temperature Rise Test System
TMP-L
-
TMP-L is according to IEC60360-1998 and GB2512-2001 (Standard method of measurement of lamp cap temperature rise). It is used to test the working and environmental temperature as well as temperature-rise of the burner and lamp. It meets the requirement of IEC and GB Standards.
-
Product
New Design 3m Electric Integrating Sphere
IS-3.0MA
-
It has all functions of IS-*MA Integrating Sphere with Holder Base.• Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere.• Please refer to article The New Design 3m Electric Integrating Sphere for more information.
-
Product
Optical Path Converter
LS512A/LS512B
-
There are many LED manufactories using two integrating spheres and one spectrophotometer to do test. The previous testing way is: when you use big sphere to test, the customer need to connect the detector cable and optical fiber from the Spectrophotometer to the big sphere, after the calibrating and then you can do the test. When you use the small sphere, you need to take away the detector cable and optical fiber from the big sphere to the small sphere, then need to calibrate again. It is too troublesome to take out the detector cable and optical fiber between the big sphere and small sphere, and you need to calibrate again for every change. The frequent change will also shorten the life of the detector cable and optical fiber.
-
Product
LM-79 Moving Detector Goniophotometer
LSG-5000
-
Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
-
Product
Auxiliary Lamp
RLS-50W
-
Due to the luminaries self-absorption, the auxiliary lamp is used to correct the flux test value. Work with the follow instruments as a System
-
Product
Masks Flame Retardant Performance Tester
WKS-1208
-
WKS-1208 Masks Flame Retardant Performance Tester is used to test the burning performance of the mask after contacting the flame at a certain linear velocity. It is special test instrument for the flame retardant performance of masks.