Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
AC/DC Withstand Voltage Test
WB2671A/WB2671B
-
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
Product
Pull Out Device
BCL-1
-
This Pull out device BCL-1 is designed and manufactured according to relevant standard requirements of IEC884-1/ GB2099.1-2008 and other electrical accessories standards, Mainly used to test the needed maximum force when the plug pull out from socket and the minimum force when single stage plug pull out from socket, and to inspect whether the socket can withstand the lateral stress imposed by electric plug into the socket. This device is applied to plugs and sockets which rated voltage no more than 250V and rated current no more than 16A.Specifications: • Weights: 36N*1, 5.4N*1, 5N*2, 4N*1, 2.6N*1; • Standard testing plug: each one for Dipolar 10A, tripolar 10A and 16A • Standard test bolt: Each one for 1.5N and 2N • 1 set of clamping device • 1 set of Weights tray • Lateral stress weights 5N*1 • 1 set of lateral stress bar
-
Product
HID Ballast Tester
WT2000-HID
-
• Input Parameters Measurement: 1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic 2) Range of voltage and current basic wave frequency: 45Hz~65Hz 3) Range of narrow frequency: 45Hz~5kHz 4) Range of wide frequency: 45Hz~1MHz
-
Product
Voltage Dips and Interruptions Generator
CSS61000-11
-
The voltage dip and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point, CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have more fine performance such as high reliability, convenient operation, and full meet the standard requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11
-
Product
Fluorescent Lamp Asymmetric Pulse Tester
UI2002C
-
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
Product
High and Low Temperature Thermal Shock Chamber
HLST-500D
-
The specimen is placed in test chamber specimen which cannot be placed in high temperature chamber or low temperature chamber. High temperature chamber pre-heats the air and low temperature air chamber pre-cools the air. When doing the test of temperature changing from high to low, the low temperature chamber will blow the pre-cooled air to the test chamber. Then, the air in test chamber will reach your target temperature in several minutes (“recover time”). When doing the test of temperature changing from low to high, the high temperature chamber will blow the pre-heated air to the test chamber. Then the air in test chamber will reach your target temperature within the recover time.
-
Product
Transient Over-voltages Tester
SUG335
-
The SUG335 is a 1.2/50μs Transient Over-voltages Tester. The polarity interval time can be at least 1s. The standard voltage waveform complies with the IEC 60335, IEC61180, IEC 62052-11: 2003, IEC 61008-1: 1996, IEC 61009-1:1996 and IEC 60947-1: 1995, IEC60060, IEC1036 surge voltage test and has been used for safety testing to determine if the clearance was fulfilled the safety requirement while the transient voltage in the circuit.
-
Product
Programmable AC Power Source
LSP-500VAC
-
• Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);
-
Product
Medical Masks Synthetic Blood Penetration Tester
WKS-8010
-
WKS-8010 Medical Masks Synthetic Blood Penetration Tester is to test the mask material with synthetic blood under continuous pressure, and visually inspect the penetration of synthetic blood on the material. It is suitable for the resistance of masks to the penetration of synthetic blood under different levels of test pressure.
-
Product
Plug and Switch Testing
-
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.
-
Product
Integrating Spheres
IS-*M
-
• Diameter: IS-0.3M (φ0.3m)、IS-0.5M (φ0.5m)、IS-1.0M (φ1.0m)、IS-1.5M (φ1.5m)、IS-1.75M (φ1.75m)、IS-2.0M (φ2.0m). Other sizes can be designed according to the customer’s request. • The painting of integrating spheres is according to CIE Pub.No.84 (1989) • Material: Pure barium soleplate (BaSO4) • BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in lighting holder position: The vertical is for E40, E27 and so on. The horizontal is for T5/T8/T12 tubes. The side assistant opening is for lighting fixtures • Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional • Power cable and socket has been build-in, it is convenient to power the testing lamp • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • The traditional integrating sphere is assembled by several pieces, Lisun Group developed A Molding Technology to produce the integrating sphere. A molding integrating sphere will be more round and the test results will be more accurate than the traditional integrating sphere
-
Product
Aging and Optical Attenuation Tester
LS822
-
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
Product
High and Low Temperature & Low Pressure Chamber
LAP-100
-
It is according to GB10590 / GB15091 low temperature / low pressure test chamber requirements; GB11159 low pressure test chamber requirements; GB / T2423. 25-1992 low temperature / low pressure integrated chamber requirement; GB / T2423. 26-1992 High temperature / low pressure integrated chamber requirement; GJB150. 2-86 low temperature / low pressure test etc standards. It’s used to test the In aviation, aerospace, information, electronics and other fields, to determine the instrumentation, Electrical products, materials, components, equipment etc.
-
Product
Impulse Test Generator
SUG-CCITT-A
-
Impulse Test Generator SUG-CCITT-A (1a. 10/700us, 6KV, figure is according to N.1 in IEC60950-1:2005 Annex N). N.1 ITU-T impulse test generators.
-
Product
Photometer
PH2000
-
The digital photometer is used with an photo detector and an integrating sphere for luminous flux lumen measurement.