Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
AC/DC Withstand Voltage Test
WB2671A/WB2671B
-
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
Product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
-
Cabinet Shell 2mm galvanized cold-rolled steel sheetCabinet Door 0.9*1.7m(L*W) 0.6*0.6mCabinet Window 0.3*0.3*0.025m(L*W*T) with 4mm hole N/APower Supply Filter 30A/220V 30A/220VInternet Line Filter RJ-45 N/ACabinet Inside Decoration PVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size 2*1.2*1.8m 0.8*0.8*0.8mAfter Packing Size 2.2*2.3*2.3m 1*1.1*1.2mAfter Packing Weight 800kg 200kgWorking With EMI-9KA/EMI-9KB EMI-9KA/EMI-9KB, PC, Testing load, and operator inside Testing load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
Product
HVR-LS Horizontal Vertical Flame Tester
HVR-LS/HVR-LSS
-
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC695-2-2 and GB Standard. It is used to test the appliances and plastic materials parts of electrical equipment for the horizontal, vertical flammability test. The product tank shell is irony spray, and configured a transparent viewing window, the digital meter shows the burning time, afterflame time, afterglow time, this device has beautiful appearance, is easy to use and has reliable performance.
-
Product
DC Bias Current Source
FD1772B
-
• Constant DC output 0-6A• Auto or manual current sweep output• 5 current range output• Output voltage range: 0-11.5V• Current accuracy ± (1%reading + 2digit)
-
Product
Digital Power Meter (AC & DC Model)
LS2012
-
• Measure Vrms, lrms, W, PF/Hz; • Measure AC, DC, AC+DC; • Automatic selecting, out of limit alarming, advance the work efficiency; • Voltage range: AC: 5-600V, DC: 1-600V. Current range: AC&DC: 0.005-20A with high measure accuracy. Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit).
-
Product
High and Low Temperature Humidity Chamber
GDJS/GDJW
-
•The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip. •The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1℃ and humidity is 0.1%R.H •The temperature sensor is platinum PT100 Ohms/MV resistor •The heating system is full separately system which produced by Nickel chromium alloy electric heating type heater •The cold system is applied by fully enclosed fan cooled single-stage and cascade refrigeration mode, the compressor is from France TECUMSEH brand which can allow you get after sales support from many countries •The cyclical system is applied by High temperature low noise air conditioning type motor and Multi blade centrifugal wind wheel •The safety self-protection function include Electric leakage, short circuit, over temperature, motor overheating, compressor pressure, overload, over-current protection •Working Power: AC380V±10% 3phases and frequency 50Hz/60Hz •Working Environmental: Temperature is 5℃~+30℃ Humidity ≤85%R.H
-
Product
Insulation Resistance Tester
WB2681A
-
• Insulation test voltages: DC250V、DC500V、DC1000V • Range of open-circuit voltage: ±10% rated voltage • Testing time: 3~99 seconds or controlled manually
-
Product
GNG-* “Go” and “Not go”gauge
GNG-*
-
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
Product
MOS Transistor Selector
UI9611
-
Measure parameters: Open voltage UGS (th), internal resistance RDS, Transconductance gm, Withstand voltage V (BR) DS• Test range: UGS (th) 0.1-9.9V; RDS 0.001-9.999Ω gm; 0.10-10.00s; V (BR) DS 50-650V• Test current range: 0.1A-5A adjustable, comply with different working situation• Automatic selecting, out of limit alarming, advance the work efficiency• The technique of testing RDS under the big-current, is advanced technique
-
Product
Damped Oscillatory Magnetic Field Immunity Tester
DOMF61000-10
-
DOMF61000-10 damped oscillatory magnetic field immunity test system included damped oscillating wave generator and single ring coil, it’s designed for to do damping oscillation magnetic field immunity test and fully meet IEC 61000-4-10, EN61000-4-10 and GB/T 17626.10 standards requirement.
-
Product
Masks Flame Retardant Performance Tester
WKS-1208
-
WKS-1208 Masks Flame Retardant Performance Tester is used to test the burning performance of the mask after contacting the flame at a certain linear velocity. It is special test instrument for the flame retardant performance of masks.
-
Product
Ball Pressure Test Device
ZBP-T
-
Made up by the related item according to IEC60695, IEC884-1, GB/T5169.21-2006, GB4706.1-2005, GB2099.1-2008, etc. • R = 2.5mm Pressure: 20N • Base with thermocouple hole • Material: 304 stainless steel
-
Product
Mask Produce and Test Machine
-
LISUN produce the bfe tester for face mask, pfe tester, melt-blown cloth electrostatic electret generator according to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1
-
Product
Portable CCD Spectroradiometer
LMS-6000
-
The Portable CCD Colorimeter Spectroradiometer has the following versions which can measure different parameters: • LMS-6000: illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000L: cd/m2, fL, Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000P: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio • LMS-6000S: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio, Rf and Rg according to TM-30 • LMS-6000F: LMS-6000 Parameters+Flicker test • LMS-6000B: LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 • LMS-6000BF: LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002
-
Product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
-
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.