Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@Lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road, Jiading District
Shanghai, 201802
China
-
Product
EFT Immunity Measurement
EFT61000-4
-
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance, such as high stability, high reliability, easy to use etc. It meets the standard requirements of IEC 61000-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in both English and Chinese.
-
Product
Constant Temperature Integrating Sphere
IS-*MT
-
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
Product
Impulse Magnetic Field Immunity Tester
IMF61000-9
-
IMF61000-9 impulse magnetic field immunity tester is high performance test instrument which special designed for to do impulse magnetic field immunity test and fully meet IEC61000-4-9, EN61000-4-9 and GB/T17626.9 standards, also it come with high intelligent, high stable performance and easy operation characteristics.
-
Product
AC Power Source
LSP-500VAR
-
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
Product
Automatic Safety Test System
LS9955/56
-
The LS9955/LS9956 Automatic Safety Test System is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It used for luminaries, home application and motor tools safety test in production line or Lab R&D.
-
Product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
-
Cabinet Shell2mm galvanized cold-rolled steel sheetCabinet Door0.9*1.7m(L*W)0.6*0.6mCabinet Window0.3*0.3*0.025m(L*W*T) with 4mm holeN/APower Supply Filter30A/220V30A/220VInternet Line FilterRJ-45N/ACabinet Inside DecorationPVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size2*1.2*1.8m0.8*0.8*0.8mAfter Packing Size2.2*2.3*2.3m1*1.1*1.2mAfter Packing Weight800kg200kgWorking With EMI-9KA/EMI-9KBEMI-9KA/EMI-9KB, PC, Testing load, and operator insideTesting load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
Product
Multiway Life Tester
CH316
-
Measure 16 samples at the same time, evaluate and record the life of each sample. Very flexible: Samples can be added and changed at anytime. The life of each sample is readable at anytime. The switch ON/OFF time is adjustable (Test period is min 1s). Automatically remember the test result when the power is off, and resume the old measurement when power is on. Sound and light alarm when the products were failed.
-
Product
IK Level Tester
IK07-10
-
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
Composite Salt Spray Test Chamber
YWX/Q-010X
-
Composite Salt Spray Test Chamber stimulate the actual natural conditions to do accelerated corrosion test, all the testing are based on common states on the natural environmental: such as combine with salt spray, hot air drying, humidity, low temperature and so on. The test samples are widely used on the intense changes in the environment, like automobile parts, aviation equipment, building materials, coating, electric and electrical machinery so on. YWX/Q-150X series is full compliance with ASTM D4728I, EC 60068-2-1, IEC 60068-2-14 and EIA/JEDEC JESD22-110-B standard requirements etc.
-
Product
Electronic Transformer Test System
UI2000-ET
-
• Input characteristics analysis 1) Measure Vrms (10-300V) Lrms (0.04-4A) W, PF, Hz, total harmonic and 0-50 component of harmonic 2) Accuracy: ± (0.4%reading + 0.1%range + 1digit) • Output characteristics analysis 1) Measure lamp voltage (1-60V) lamp current (03-20A) lamp power, crest factor and oscillatory frequency 2) Accuracy: Class 2 • It can print without compute, and provide the communication port for PC
-
Product
Integrating Sphere
-
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
Product
Environmental Test Chamber
-
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
Product
Reflection/Transmission Test Chamber
CHTR-100
-
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.
-
Product
Mask ventilation resistance and pressure differential tester
WKS-3102
-
Mask ventilation resistance and pressure differential tester is used to measure the inhalation and exhalation resistance of mask under specified conditions. Applicable to mask manufacturers, labor protection equipment inspection agencies to carry out related testing and inspection of mask products, mask breath resistance tester, breathing valve air tightness tester, breath resistance machine for measuring respirator and mask protection products in Inspiratory resistance and expiratory resistance under specified conditions.
-
Product
Multi-Functional Selector
UI9600A
-
How to test a transistor with digital transistor selection tool? Please check the belowing Transistor’s Multi-Functional Selector measurement.















