-
product
Current Preamplifier
1641
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
product
Preamplifier
The UBBV series are external, extremely low-noise broadband preamplifiers that can be mounted to any SPECTRAN spectrum analyzer. They are ideally suited for spectrum analyzers and oscilloscopes as well as antennas of all manufacturers and are supplied with extensive accessories.
-
product
Low Noise Pre-Amplifiers
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
product
Universal Preamplifier 14
UP14
For Two Dimensional Magnetic Recording (TDMR) and Heat-assisted Magnetic Recording (HAMR) Headamplifiers. Universal Preamplifier 14 (UP14) is designed for TDMR and HAMR Head Amplifiers. With new Guzik RWA4000 TDMR, UP14 allows to process signals from three Read Channels. It also supports two high speed data channels for Write data and Laser data. UP14 has two channels for dynamic TFC control and allows to program TFC power per sector and close loop TFC power control in each channel. UP14 can generate two programmable modulation signals for write data and laser data with bandwidth up to 20 MHz. UP14 consist of two boards. The first UP14 RW Board processes high-frequency signals: read-back signals, write data and laser data. The second UP14 Control Board provides power, control and low-frequency signal generation: TFC, write data modulation and laser modulation.
-
product
Programmable Current Preamplifier
99539
The Model 99539 is a modular, multi-channel current preamplifier with parallel, logic level, gain control input. It consists of circuit boards which plug into a 3 1/2" high by 19" wide rack chassis.
-
product
Microphone preamplifier
PRE-01
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
product
Preamplifier
Is designed for the amplification of measuring signals, e.g. weak signals of near field probes with high resolution.
-
product
Sensitivity Testing
Response Dynamics Vibration Engineering, Inc.
Sensitivity testing involves making predictions of system response to environmental disturbance. The significance and importance of the system sensitivity estimates is very often overlooked. This gets companies in trouble and is one of the top reasons why we are called upon to provide timely solutions. Most teams are focused on getting their product to work and get it out the door. An engineering team will often not know how to quantify what to expect in the customer environment and how to test for those expected disturbances. We design hundreds of sensitivity tests and can explain the important concepts to consider in designing the tests and making the right measurements that allow for sound estimates of system response. This is an important expertise we use in our vibration, acoustic and magnetic field consulting services.
-
product
Microphone Preamplifier
426A30
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
product
Low Noise Differential Preamplifiers
Provide a high gain amplification to 1MHz with an AC output derived from a very low noise FET instrumentation amplifier. Each model has fixed gain settings of x1 (0dB), x10 (20dB), x100 (40dB) and x1000 (60dB) over a selectable bandwidths of 100Hz, 1kHz (HP), 3kHz, 30kHz, 100kHz and 1MHz (7000 model only). Noise referred to input is 7nV√Hz and common mode rejection is >100dB at 1kHz. Momentary pushbutton switches are provided that control coupling, bandwidth, gain and channel on/off selections. BNC connectors are provided for single-ended and differential input, ac output, and dc output (optional) connections.
-
product
Lock-In Voltage Preamplifier
SR550
Stanford Research Systems, Inc.
The SR550 Voltage Preamplifier is designed to work with any SRS lock-in amplifier. Preamplifiers provide gain close to the experimental detector, before the signal-to-noise ratio is permanently degraded by cable capacitance and pickup
-
product
High Sensitivity Reed Relays
Series 87
General purpose relays - sensitive versions of series 85 and 89
-
product
Preamplifiers
Is an electronic amplifier that converts a weak electrical signal into an output signal strong enough to be noise-tolerant and strong enough for further processing, or for sending to a power amplifier and a loudspeaker.
-
product
350 MHz Preamplifier
SIM914
Stanford Research Systems, Inc.
The SIM914 350 MHz Preamplifier contains two wide-bandwidth, DC-coupled amplifiers, each with a gain of 5 (14 dB). Its fast rise time, low noise and excellent DC accuracy make it an ideal instrument for amplifying signals like those from photomultiplier tubes and photodiodes.
-
product
Mm-Wave High Sensitive Power Meters
The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.
-
product
Transformer Preamplifier
SR554
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
product
Spectral Response (Spectral Sensitivity) Measurement
It is used to measure the spectral response (spectral sensitivity) of photoelectric conversion devices (photodetectors / sensors) such as silicon photodiodes and CCD · CMOS image sensors . Measurement in the broadband wavelength region can be performed with low stray light.
-
product
RX Pre-Amplifier System
RAM-34
The RAM-34 is a complete pre-amplifier system designed primarily for the low bands 160M thru 40M. It has inputs for four receive antennas and internal 3-pole bandpass filters for 160M, 80M and 40M. In addition to the pre-amplifier, it has a step attenuator that togetherwith the amplifier stage provides gains from -20 dB to +20 dB in 5 dB steps. This allows equalizing the signal levels between the antenna inputs. Gain settings are memorized for each antenna on each band. Different types of receive antennas have different signal levels and the gain memories eliminate the need to adjust the receiver or pre-amplifier when switching between the antennas.
-
product
Thermal Sensitivity Tester
NTE-2A
The NTE-2A Thermal Probe is a sophisticated, non-invasive device for the clinical evaluation of neuropathy and the assessment of short fiber neurological function. Individual thresholds are compared to normals to statistical normals. These results provide an accurate means of tracking chronic changes in small fiber nerve function. It can be used for pain studies and in any application were a variable, accurately-controlled temperature stimulus is required. The NTE-2A is often used in conjunction with the Vibratron II to assess peripheral neuropathies.
-
product
Highly Sensitive Silica Monitor
SLIA-300
Highly sensitive silica monitor for ultrapure water management in semiconductor/FPD processes
-
product
High Sensitive Radiometers for Plasma Diagnostics
ELVA-1 radiometers for plasma diagnostic are worldwide known product. The custom designed ECE radiometers have been installed at lots of Tokamaks
-
product
X-Ray Preamplifier Power Supply
The X-ray Preamplifier Power Supply (XPPS) provides power for 50 or more preamplifiers. The 19-inch rack-mount or benchtop unit contains linear power supplies that generate +/-12V @ 5.1 Amperes and +/-24V @ 3.6 Amperes, with very little noise.
-
product
C-Band DWDM Pre-Amplifier EDFA (WPA-C)
HWA4300 (With SNMP)
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HWA4300 series, is designed for C-Band 44 waves or 88 waves DWDM system design Pre-Amplifier gain flatness. Products using the most excellent optical performance, the most advanced electronic control technology and comprehensive software features, has a wide operating wavelength range, Low noise, excellent gain flatness characteristics and transient characteristics.
-
product
High-Sensitivity Tri-Axial Accelerometer with Built-In Preamplifier
NP-7310
NP-7310 is the accelerometer with built-in preamplifier, and capable of tri–axial directions simultaneous measurement. It is suitable for the low frequency vibration measurement such as ground vibration or floor vibration while operating the machine. NP-7310 can be used with the sensor amplifier unit such as AU-2100, AU-2300 or PS-1300. Also, it is possible to input directly to the analyzer or recorder which the constant current amplifier is built-in such as the FFT Analyzer of DS-2000 series, DS-3000 series, CF-7200A, CF-9000 series or CF-3650/3850 series.
-
product
Preamplifier, 10 MHz to 4 GHz
87405B
Preamplifiers and System Noise Figure Application Note This note discusses noise figure basics including applications and characteristics of Keysight simplifier technology. Highlighted are Keysight's 87405C portable preamplifiers that provide an exceptional gain of 25 dB up to 18 GHz and a probe-power bias connection which eliminates the need for an additional DC power supply. Read the Preamplifiers and System Noise Figure Application Note now!
-
product
USB Preamplifier, 2 to 50 GHz
U7227F
The U7227F, 2 to 50 GHz USB preamplifier is designed to bring reliable gain and low noise figure to measurement systems improving the overall system performance and reduce systematic errors; a total solution to the X-Series signal analyzers to perform noise figure measurement
-
product
Microphone Preamplifier
426B03
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
product
High Sensitivity Shock0 to 5g
TGP-0605
The TGP-0605 measures low level impacts and can be used for machine condition monitoring and the monitoring of expensive and/or fragile shipments.
-
product
JFET Voltage Preamplifier
SIM910
Stanford Research Systems, Inc.
The SIM910 and SIM911 are low-noise, programmable preamplifiers which are ideal for a wide range of small signal applications. The primary differences between the two models are their input impedance and input noise.
-
product
High Sensitivity Anemometer for Very Low Wind Speeds
HD53LS… Series
2-axis ultrasonic static anemometer - high sensitivity to dectect very low speeds. Measurement of wind direction, wind speed and wind gust.





























