Gen3 systems
Following over 2 years of intense research and development, we are proud to introduce the next generation of equipment used to measure changes in Surface Insulation Resistance.
-
AutoSIR2™ -
Gen3 Systems Limited
One AutoSIR chassis can hold between 1 to 16 measurement cards and can monitor up to 256 x 2-point test patterns or 78 x 5-point test patterns, or 32 x 9-point test patterns at selectable intervals from minutes to days. Each channel is current limited (1 M Ω), ensuring that dendrites are preserved for failure analysis. The frequent monitoring capability provides a full picture of the electrochemical reactions taking place on a circuit assembly, and provides early trend analysis enabling tests to be curtailed, thus saving considerable test time and money.
-
National Technical Systems
Surface Insulation Resistance (SIR), as defined by IPC, is the electrical resistance of an insulating material between a pair of contacts, conductors, or grounding devices that is determined under specified environmental and electrical conditions.In respect to the world of printed circuit boards (PCBs) and printed circuit assemblies (PCAs), SIR testing—also commonly referred to as Temperature Humidity Bias (THB) testing—is used to evaluate a product’s or a process’ ability to resist “failure” by means of current leakage or an electrical short (i.e., dendritic growth). SIR testing is typically performed under elevated temperature and humidity conditions—such as 85°C/85% RH and 40°C/90%—with periodic insulation resistance (IR) measurements obtained.
-
Axi'An Beicheng Electronics Co., LTD.
Electronic Power Testers by RuoShui; HART process calibrators, process calibrators, digital earth resistance tester, insulation resistance tester, SMD resistor, digital capacitance inductance meter, LCR meters, surface resistance meter, and more
-
N1424C -
Keysight Technologies
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
N1424B -
Keysight Technologies
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
N1424A -
Keysight Technologies
The N1424A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424A to the B2985B/87B.
-
Model 717 -
Magnetic Instrumentation Inc.
The Model 717 Franklin Tester provides a means of testing single strips or punchings of flat rolled electrical steel, for surface insulation resistance under predetermined conditions of voltage and pressure.
-
UL 746A -
National Technical Systems
The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).
-
SCR ELEKTRONIKS
Dry Arc Resistance Tester is designed to conduct high voltage,low current Arc Resistance test on solid electrical insulation material as per:ASTM standard D495-99 (2004) and UL 746A. Why Arc Resistance Test? Many Cases of insulator failure are due to deterioration of its surface because of sustained electrical discharge or Arc. This test method is intended to test the resistance of insulating material when a high -Voltage low -current Arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to decomposition and erosion.AdvantagesThis Test ensures that your products meet high standards of quality & safety. This product is meant for all Switchgears/ insulator/ Polymer/ electro plastic manufacturers and manufacturers who use insulators in their products e.g. Wiring Accessories, Appliances, HT/LT line insulators etc.
-
Junxy Energy
Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.
-
Macom Technology Solutions Holdings Inc.
MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss leveraging nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long-term stability.
-
ASTM D257 -
National Technical Systems
These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.
-
Macom Technology Solutions Holdings Inc.
MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss due to our use of nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs high Q MNOS series of capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long term stability.