Product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
Product
18.5" (FHD) Modular Front Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-D18W-FCE
-
350 cd/m² luminance with 1920 x 1080 (FHD) resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
Beam Pattern Measurement System
BP100
-
The BP100 is purpose-made for luminous intensity measurement of lamps, using a diffusely transmitting screen to provide a flat image that can be measured by an imaging photometer. This is a low cost, versatile solution in comparison to the traditional method of measuring lamp properties as a function of angle of emission, using Goniometers that are often costly and dedicated for one specific measurement.
-
Product
Portable Luxmeter
HD2102.1
-
Portable handheld luxmeter for measuring illuminance, luminance, PAR, irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).
-
Product
GO-SPEX100 Goniospectroradiometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-SPEX100 delivers photmetric, colorimetric, electrical comprehensive test function for LEDs, and built-in precision temperature control platform,not only for measuring the specific temperature of the photometric and colorimetric parameters of LED, but also to measure the characteristics curve of its photometric and colorimetric performance with temperature.The test parameters include: spatial luminous intensity distribution curve, luminous flux, spatial spectral distribution, relative spectrum, absolute spectrum, color parameter, forward current and forward voltage, etc.
-
Product
21.5" (FHD) Modular Front Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-D21W-CE
-
250 cd/m² luminance with 1920 x 1080 (FHD) resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
LED Optical Meters
-
Measure the optical characteristics of white LEDs and LED lighting during production. Measure Luminous Intensity, Chromaticity, and Color Rendering Index
-
Product
Isolation Amplifier Digital Output
-
This coupler is an optically coupled isolation amplifier that uses an IC with a high-accuracy sigma-delta A/D converter and a GaAIAs light-emitting diode with high-speed response and high luminance efficiency on the input side, and an IC with a digital signal (MDAT, MCLK) output function on the output side. This coupler is designed specifically for high common mode transient immunity (CMTI) and high linearity (nonlinearity) applications, making it ideal for current sensing in motor drives.
-
Product
Lamp-Based Calibration Light Sources
-
Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.
-
Product
Universal Instrument for Measurement
MI-6201 Multinorm
-
Universal all-in-one instrument for measurement of air temperature, air velocity, relative humidity, illuminance, luminance and the Class 1 (Pro Set) or Class 2 (Euro Set and Standard Set) sounds analyses.
-
Product
Isolation Amplifier Analog Output
-
This coupler is an optically coupled isolation amplifier that uses an IC with a high-accuracy sigma-delta A/D converter and a GaAIAs light-emitting diode with high-speed response and high luminance efficiency on the input side, and an IC with a high-accuracy D/A converter on the output side. This coupler is designed specifically for high common mode transient immunity (CMTI) and high linearity (nonlinearity) applications, making it ideal for current sensing in motor drives.
-
Product
Photometers & Colorimeters
-
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
Product
Light-resistant Integrating Sphere
-
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
Product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
-
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Display Measurement Systems
DTS Series
-
Instrument Systems Optische Messtechnik GmbH
Characterization of emissive, transmissive, reflective, and transflective displaysViewing-angle-dependent analysis of illuminance, contrast, color, and derived parametersDetermination of the electro-optical transfer function: analysis of luminance, contrast, and color depending on electrical driving conditionsMeasurement of transient properties, such as switching times, flicker, and modulation
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
Haze Meter
DRKWGT-2S
-
Shandong Drick Instruments Co., Ltd.
DRKWGT2S transmittance / haze analyzer is a computerized automatic measuring instrument which is designed based on the People's Republic of China national standard GB241080 "transparent plastic light transmittance and haze test methods" and the American Society for testing and materials standard ASTM D100361 (1997) Standard Test Method for Haze and Luminous Transmittance of Transparent Plastice." It could apply to all transparent, translucent parallel plane sampler (plastic plates, sheets, plastic film,sheet glass) of light transmittance, transmission haze and reflectivity test also applies to liquid samples (water, beverage, pharmaceutical, colored liquid, grease) turbidity measurements in defense research and production workers and peasants to have a wide range of applications.
-
Product
Spectroradiometer
-
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
Product
S2 Penta High-Sensitivity Sensors
ULP S2 PCI/V HS
-
The Universal LightProbe S2 Penta High Sensitivity Sensor features the same popular built-in color binning as the regular S2 Penta Sensor, and is designed test extremely dim LEDs, providing an analog output for intensity, ranging from 0 to 4 volts, corresponding to the LED’s luminous intensity in millicandelas. Implemented in a unique and customizable 2-Part solution, the S2 Penta High Sensitivity Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longTypical response times: <1.2s color & intensity outputs simultaneously (the brighter the LED, the shorter theresponse time)Fiber-Optic Probes: Wide Aperture Fiber-Optic Probe recommended
-
Product
PCE Series Opto-Electric Measurement System
-
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
Product
12.1" (4:3) High Brightness Modular Front Display Design Compatible With TPC-B520, TPC-B300 Models
FPM-D12T-HE
-
Sunlight readable with 1000 cd/m² luminance with 1024 x 768 resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
Aging and Optical Attenuation Tester
LS822
-
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
Product
Optical Meters
-
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
Product
GO-NR1000 Near-Field Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for LED light source, LED chip, module and other small light source, the principal function includes: spatial light intensity distribution curve, spatial color distribution curve, iso-lux curve, total luminous flux, effective luminous flux, spatial luminance curve, etc.The test data can be saved as IESNA (*.ies), CIBSE (*.cib), EULUMDAT (*.ldt), CIE (*.cie), CEN (*.cen) and other formats, which can be directly used as the input data of international general lighting design software. Spatial luminance data can be imported into near-field lighting generation software to generate light data that can be imported into third parties (TracePro and LightTools).
-
Product
23.8" (FHD) Modular Front Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-D24W-CE
-
350 cd/m² luminance with 1920 x 1080 (FHD) resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
Calibration and Measurement Services
-
A uniform light source which provides spatially uniform luminance and illuminance for flat-field correction and calibration imaging systems, calibration photometers and spectroradiometers.
-
Product
Integrating Spheres
IP-Series
-
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
Product
Light / Lux Meter, 40000 lx, 0.1 lx, 157 mm, 54 mm, 34 mm
72-9195
-
Handheld light meter provides a live reading of luminance in most environments. Convenient size easily slips in your pocket or tool kit.
-
Product
Automated Routine Analysis of Waters by Purge & Trap Concentration
AQUATek LVA
-
The AQUATek LVA is a full automation solution for routine analysis of waters by purge and trap concentration. It utilizes a fixed volume loop that is filled with liquid sample, internal and/or surrogate standards are added, and then the sample is transferred to the Lumin or Stratum PTC. Upon completion of the purge step by the concentrator, the AQUATek LVA then initiates a clean up cycle where the sample loop and concentrator sparger are cleaned with 90o C water via the two-stage water heater.
-
Product
Goniophotometer
-
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.