product
Backlights for Machine Vision
Backlighting is one of the most important components of machine vision systems; it must provide the required luminous flux, response speed, area and duration of exposure. Our experience in machine vision systems led us to the need to develop an LED backlight module for flash operation.
-
product
Luminance Colorimeter
XYL-VI
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.
-
product
Goniophotometer Test System For Led Lamp
LCG-1680B
Shenzhen Chuangxin Instruments Co., Ltd.
Design according to IEC61341the test method of central luminous intensity and beam angle for reflecting light, this instrument can be used to test the cross section luminous intensity distribution curve, central luminous intensity and effective beam angle of LED assembled luminaries and LED lens system with diameter less than 180mm.
-
product
Beam Pattern Measurement System
BP100
The BP100 is purpose-made for luminous intensity measurement of lamps, using a diffusely transmitting screen to provide a flat image that can be measured by an imaging photometer. This is a low cost, versatile solution in comparison to the traditional method of measuring lamp properties as a function of angle of emission, using Goniometers that are often costly and dedicated for one specific measurement.
-
product
LED626/620 Goniophotometer For LEDs
Hangzhou Everfine Photo-E-Info Co., LTD
It can measure the luminous intensity data and automatically plot the luminous intensity distribution curve and luminous flux, and the test conditions meet the CIE condition A (far field) or condition B (near field).In addition, the software can provide customers with 3D luminous intensity distribution graphic.
-
product
Spectral Light Meters For Photometric And Colorimetric Measurements
Comprehensive range of spectroradiometers for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens), luminous intensity (cd) as well as the colorimetric characteristic values such as chromaticity coordinates (x,y,u',v') or color rendering index (CRI), etc.
-
product
Digital Screen Checker
Harkness Screens International Ltd
The low-cost digital cinema luminance meter for accurately measuring screen brightness. Now available, the Digital Screen Checker is an ideal tool for projection managers / projectionists or service engineers to monitor screen brightness and check lamp life. The Digital Screen Checker from Harkness Screens helps exhibitors to ensure that their presentations remain at optimum levels and ensure DCI-compliancy.
-
product
Photometers & Colorimeters
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
product
Spectral Radiance / Luminance Calibration Standards
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
product
Light Sources
There are many low cost artificial light sources used for illumination or for industrial applications: tungsten or halogen bulbs, fluorescent lamps, LED lamps etc. Some of these sources have regulated intensity of emitted light. However, there very few calibrated light sources of precisely known parameters. A light source can be considered as calibrated when its user can precisely regulate its photometric/radiometric parameters like luminance (or illuminance), radiance (or irradiance) at defined spectrum of interest. Such light sources are needed in many applications among them, in systems for testing night vision devices, VIS-NIR cameras and SWIR imagers. Inframet offers a series of calibrated light sources that can be divides into three groups:
-
product
CAS-200 Compact Array Spectrometer
CAS-200
Hangzhou Everfine Photo-E-Info Co., LTD
CAS-200 can quickly and accurately measure the spectral power distribution in the range of 380nm ~ 780nm, mainly measuring: the relative spectral power distribution, chromaticity coordinate, color temperature, color rendering index, color tolerance, peak wavelength, FWHM, luminous flux (with integrating sphere) of traditional lamps/light sources, single LED, LED modules and other electric light sources.
-
product
Photometric Probes for Illuminance
LPPHOT03… Series
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
product
Backlight Module Optical Measurement System
RayClouds Photoelectric Technology Co.,Ltd.
The DM series backlight module optical characteristic automatic measurement system is equipped with photometer, colorimeter and spectroradiometer to measure the luminance and chrominance, uniformity of the backlight module.
-
product
Spectroroadiometer
SR Series
Spectroradiometer "SR series" can measure spectral, luminance and chromaticity with high accuracy.
-
product
Optical Meters
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
product
GO-2000 Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
GO-2000 is a highly automated luminaire light distribution performance test system, mainly used for all kinds of indoor lamps, road lamps and floodlights ( add B-β test accessories) light distribution performance test, total luminous flux test and electrical parameters (voltage, current, power, power factor) measurement.
-
product
GO-NR1000 Near-Field Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for LED light source, LED chip, module and other small light source, the principal function includes: spatial light intensity distribution curve, spatial color distribution curve, iso-lux curve, total luminous flux, effective luminous flux, spatial luminance curve, etc.The test data can be saved as IESNA (*.ies), CIBSE (*.cib), EULUMDAT (*.ldt), CIE (*.cie), CEN (*.cen) and other formats, which can be directly used as the input data of international general lighting design software. Spatial luminance data can be imported into near-field lighting generation software to generate light data that can be imported into third parties (TracePro and LightTools).
-
product
Absolute Luminous Flux Integrators
Photometric Solutions International Pty Ltd
The Absolute Luminous Flux Integrator (ALFI) is a special device for absolute measurement of the luminous flux output of lamps. It can also to measure the luminous intensity distribution of small lamps and luminaires.
-
product
Standard Light Source
SLS-50W
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
product
Illuminance (lux) Probe
LPPHOT01
The LPPHOT01 probe measures illuminance (lux) defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m2).
-
product
Goniophotometer Test System For Led Lamp
1680A 1680B
Shenzhen Chuangxin Instruments Co., Ltd.
Design according to IEC61341,the test method of central luminous intensity and beam angle for reflecting light, this instrument can be used to test the cross section luminous intensity distribution curve, central luminous intensity and effective beam angle of LED assembled luminaries and LED lens system with diameter less than 180mm.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Calibration and Measurement Services
A uniform light source which provides spatially uniform luminance and illuminance for flat-field correction and calibration imaging systems, calibration photometers and spectroradiometers.
-
product
Near-field Goniophotometer
RiGO801
TechnoTeam Bildverarbeitung GmbH
Correct determination of the luminous intensity distributions (lid) of lamps and luminaires far within their photometric near-field range. Capture of ray data.
-
product
HAAS-3000/2000 High Accuracy Array Spectroradiometer (Laboratory Grade)
HAAS-3000
Hangzhou Everfine Photo-E-Info Co., LTD
HAAS-3000/2000 High Accuracy Array Spectroradiometer delivers various photometric, colorimetric and radiometric parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
product
Light / Lux Meter, 40000 lx, 0.1 lx, 157 mm, 54 mm, 34 mm
72-9195
Handheld light meter provides a live reading of luminance in most environments. Convenient size easily slips in your pocket or tool kit.
-
product
Instrumented Runway Visual Range Transmissometer System
AGIVIS 2000
Aeronautical & General Instruments Ltd.
AGIVIS 2000 is a transmissometer-based Runway Visual Range (RVR) system that provides the highest possible levels of accuracy. The first generation of AGI RVR systems were developed in co-operation with the UK Met Office and CAA, and AGI has been supplying RVR systems for more than 25 years. AGIVIS 2000 systems are currently operational at major international airports certified for instrument landings up to and including CAT IIIB. AGIVIS 2000 is fully compliant with ICAO, WMO and CAA requirements. The system consists of transmissometer field sites, background luminance meters, runway lighting interfaces, data processing equipment and archive storage and backup. It can drive multiple full-colour dedicated RVR displays. Systems can be supplied fully installed with comprehensive engineering and operator training, and post-installation support is available worldwide.
-
product
Purge & Trap Concentrator
Lumin
In 1974, Tekmar revolutionized the way laboratories performed volatile organic compounds testing. Since then, Tekmar has continued to build on the foundation of the initial Purge and Trap technique for volatile organic compounds, one innovative layer at a time. The Lumin builds on seven previous generations, making Tekmar the industry’s cornerstone of the Purge and Trap process and support.
-
product
LED Luminous Intensity Distribution Tester
LS860
LS860 Luminous Intensity Distribution Tester is a precise electronic instrument for measuring LED luminous intensity. It’s strictly designed according to LED standard requirements of CIE 127-1997 A or B Condition.