Filter Results By:

Products

Applications

Manufacturers

Showing results: 3256 - 3270 of 3585 items found.

  • PCIe-6341, PCI Express, 16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO Multifunction I/O Device

    781046-01 - NI

    PCI Express, 16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO Multifunction I/O Device - The PCIe‑6341 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. The device delivers high-performance functionality leveraging the high-throughput PCI Express bus and multicore-optimized driver and application software. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PCIe‑6341 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • PCIe-6320, PCI Express, 16 AI (16-Bit, 250 kS/s), 24 DIO Multifunction I/O Device

    781043-01 - NI

    PCI Express, 16 AI (16-Bit, 250 kS/s), 24 DIO Multifunction I/O Device - The PCIe‑6320 offers analog input, digital I/O, and four 32‑bit counters/timers for PWM, encoder, frequency, event counting, and more. The device delivers high-performance functionality leveraging the high-throughput PCI Express bus and multicore-optimized driver and application software. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PCIe‑6320 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • GPIB-RS485/RS422 GPIB Instrument Control Device

    779733-02 - NI

    Serial, RS485/RS422 GPIB Instrument Control Device - The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-RS485 RS422 GPIB Instrument Control Device

    779733-01 - NI

    Serial, RS485/RS422 GPIB Instrument Control Device - The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • PXI-5671, 2.7 GHz RF Vector Signal Generators

    779079-04 - NI

    2.7 GHz, Digital Upconverter Included, PXI Vector Signal Generator—The PXI‑5671 features quadrature digital upconversion, which reduces waveform download and signal generation time. It is a general-purpose vector signal generator that can generate standard modulation formats such as AM, FM, PM, ASK, FSK, MSK, GMSK, PSK, QPSK, PAM, and QAM. The PXIe‑5671 delivers a highly flexible and powerful solution for scientific research, consumer electronics, communications, aerospace/defense, and semiconductor test applications as well as emerging areas including software-defined radio, radio frequency identification (RFID), and wireless sensor networks. For specific communications standards, you can use various software add-ons to generate modulated signals according to standards such as WCDMA, DVB‑H, and ZigBee

  • PCI-8513, 2-Port, Software‑Selectable/FD CAN Interface Device

    780684-02 - NI

    2-Port, Software‑Selectable/FD CAN Interface Device—The PCI‑8513 is a controller area network (CAN) flexible data-rate (FD) interface for developing applications with the NI‑XNET driver. NI‑XNET software-selectable CAN interfaces offer the best flexibility for CAN development with onboard transceivers for high-speed/FD, low-speed/fault-tolerant, and single-wire CAN as well as any external transceiver. The PCI‑8513 excels in applications requiring real‑time, high‑speed manipulation of hundreds of CAN frames and signals such as hardware‑in‑the‑loop simulation, rapid control prototyping, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts.

  • PCI-8513, 1‑Port, Software‑Selectable/FD CAN Interface Device

    780684-01 - NI

    1‑Port, Software‑Selectable/FD CAN Interface Device—The PCI‑8513 is a controller area network (CAN) flexible data-rate (FD) interface for developing applications with the NI‑XNET driver. NI‑XNET software-selectable CAN interfaces offer the best flexibility for CAN development with onboard transceivers for high-speed/FD, low-speed/fault-tolerant, and single-wire CAN as well as any external transceiver. The PCI‑8513 excels in applications requiring real‑time, high‑speed manipulation of hundreds of CAN frames and signals such as hardware‑in‑the‑loop simulation, rapid control prototyping, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts.

  • Vehicle Multiprotocol Interface Module

    C Series - NI

    C Series Vehicle Multiprotocol Interface Modules use hardware-selectable NI-XNET Transceiver Cables (TRC) to communicate High-Speed/Flexible Data‑Rate CAN, Low-Speed/Fault Tolerant CAN, and/or LIN. Using the NI-XNET driver, you can create applications that require real-time, high-speed manipulation of hundreds of CAN and/or LIN frames and signals. The NI-XNET device-driven DMA engine enables the onboard processor to move frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time. C Series Vehicle Multiprotocol Interface Modules work well in applications such as hardware-in-the-loop (HIL) simulation, rapid control prototyping, bus monitoring, and automation control.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • Automated Wafer Handler up to 450mm

    GPR-GB7S - Genmark Automation

    The GB7S Robot System employs Genmark’s breakthrough and patented GPR™ Technology to achieve the highest level of performance currently available in an automated wafer handler which is capable of handling up to 450mm diameter wafers. The patented GPR technology enables the servo-controlled robot to interface compliantly and intelligently with misaligned cassettes, FOUPS and process modules, as well as provide software-controlled end-effector deflection compensation during transport of heavier payloads. The unique and patented YAW technology feature of the GPR-GB7S Robot System enables it to access in-line process modules, FOUPS and cassettes from a fixed centralized location, and eliminates the need for radial placement of process and other stations around the robot. The GB7 Robot System can have various arm configurations to accommodate a wide range of SMIF/cassettes front-end layouts.

  • Industrial Automation Solutions

    LXinstruments GmbH

    LXinstruments FCT systems for industrial electronics assemblies are particularly suited for applications with a large variant diversity for medium volume sizes. They are used for testing utility electronics as well as for drive control and grid management systems. We have also implemented systems for functional test, repair and calibration of decentralized PLC I/O assemblies.Since early failures in the field often lead to enormous costs, we not only provide functional test systems, but also burn-in systems for simultaneous testing of many assemblies in a climate chamber. Due to the modular structure of our software, it is possible to establish a logical separation between the definition of the climatic profile to be executed and the actual test sequence, during which the different electrical tests are processed. Connections to HALT/HASS systems can also be established without problems.

  • Network Analyzer

    DPNA-6G AXIe - Holding Informtest

    The AXI DPNA-6G module is the world's first network analyzer in the form factor of the AXIe-1 module, as well as the first Russian device that meets the AXIe-1 standard. In the mode of the network parameters meter, the AXI DPNA-6G module measures the vector values ​​of the network parameters on two ports: transmission coefficients (S12, S21) and reflection (S11, S22). At the same time, all necessary types of calibrations are supported: one- and two-port short-circuit, XX, matched load, transmission normalization. The software supports the import of third party calibration standard parameters. In the measuring receiver mode, the module provides:*generation of a harmonic signal (frequency synthesizer);*spectrum analyzer and power level in a given band;*measuring the frequency of a known signal;*measurement of analog modulation parameters;*phase noise measurement.

  • Battery Tester

    G5.BT - Regatron AG

    The G5.BT series is bidirectional regenerative. It was developed specifically for testing energy storage devices and is suitable for use in laboratories and on test benches. The modular and finely graded G5.BT series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The G5.BT series has an outstanding current accuracy of <0.02% FS, an additional high-resolution current measurement range, and a fast current rise time in the 100 μs range. Ripple modulation, an integrated safety relay for PL c according to EN ISO 13849 and a powerful CAN multi-protocol interface (1 kHz, 16 bit) as well as functions to avoid reverse-polarity problems, current surges, and unwanted deep discharges make the G5.BT series the ideal, versatile battery module and battery pack tester.

  • Active Loop Antenna

    AL-130R - Com-Power Corporation

    Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.

  • Cells and Electrodes

    Bank Elektronik

    Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.

Get Help