Filter Results By:

Products

Applications

Manufacturers

Showing results: 1246 - 1260 of 1353 items found.

  • Pressure Temperature Sensors

    Teledyne Marine Cormon

    The PT sensor has been designed to the highest industry standards to provide customers with dependable and accurate measurement of temperature (+/- 0.50C) and pressure (0.025% FSD) within a high integrity mechanical package. The sensor is available in both 10k and 15k psi configurations and incorporates true dual redundant sensors and electronics. Combined with the addition of a tertiary barrier between the process fluid and sea water, operators and users can be assured of high integrity data with a design life of >25 years. The unit offers operators flexible communications interfaces as standard covering CANbus (CiA443, SIIS Level 2), MODbus (RS485) or 4-20mA outputs.

  • Dual Frequency 900 kHz & 2250 kHz 2D Imaging Sonar

    BlueView M900-2250-S 130/45-Mk2 - Teledyne Marine BlueView

    ​The dual frequency M900/2250-S 130/45-Mk2 is a new configuration of the leading BlueView M900/2250 optimized for superb image quality in challenging shallow water environments. The 900 kHz offers high-resolution long range navigation, object detection, and obstacle avoidance, while the 2250 kHz provides ultra-high resolution at close range. ROV navigation, diver hand held, hull inspections, structure inspections, diver monitoring, and search and recovery are a few applications that benefit from the dual-frequency’s imaging capabilities. All M Series sonar operate while in motion or from a stationary position delivering real-time imagery and data.

  • ExStik® Conductivity/TDS/Salinity Kit

    Extech EC410 - Extech Instruments Corporation

    EC410 kit includes EC400 ExStik® Conductivity/TDS/ Salinity Temperature Meter, with sensor, protective cap, three calibration standards, (30mL bottle each), weighted base, 3 sample plastic cups, with caps, four 3V CR-2032 batteries, 48 in. (1.2 m) neck strap, and carrying case. Autoranging meter offers 3 ranges of measurements from tap water to wastewater and any aqueous solution. Automatic Temperature Compensation of 2% per °C. Data Hold, Auto Power Off and low battery indication. Internal memory stores up to 25 labeled readings for easy recall.

  • Mid-Range Gas Filter Correlation CO Analyzer

    Model N300M - Teledyne Advanced Pollution Instrumentation

    The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

  • Digital Brix Refractometer - for Measuring Dissolved Sucrose in Liquids

    Extech RF153 - Extech Instruments Corporation

    Take quick and accurate % Brix or Refractive Index (RI) measurements of dissolved sucrose level in liquids for beverage and food production, determine maturity of fruits and plants, or control the concentration of industrial fluids (such as cutting coolants, hydraulic fluids, and antifreeze) to extend equipment life and prevent corrosion. Fast three second response time, the LCD displays %Brix or RI and Temperature. The RF153 fits in the palm of your hand and it features built-in ATC, single Zero calibration, prism cover, and auto memory storing 10 readings. Rugged low maintenance water resistant (IP65) housing with convenient side spouts for easy drainage.

  • UV Testing Machine

    Dongguan Kejian Instrument Co., Ltd.

    1. Meet ISO,ASTM, DIN,JIS,SAE,BS,ANSI,GM,U.S.GOVT(ASTMG153,ASTMG154,,ASTMD4329,ASTMD4977,ASTMD4587,SAEJ2020,ISO4892)2. QUV condensation device simulates the effect of humidity of outdoor,meeting 100% humidity.3. Electronic-eye irradiance control system4. Use blackboard temperature sensor providing precise temperature and recuring test result.5. Perform humidifying, condensation and water spraying circulating test.6. Irradiance is calibrated by CR-10 calibrator and automatic calebration procedure.(Paten technology)7. Specimen size and quantity: 75mm×300mm 24pcs, 75mm×150mm 48pcs

  • Belimo Energy Valve

    BlueLight Technologies

    The Energy Valve is a pressure-independent valve that measures and manages coil energy by using an embedded electromagnetic or ultrasonic flow meter, along with supply and return water temperature sensors. The Energy Valve also has the patented Power Control and Belimo Delta T Manager logics built-in that monitor coil performance and optimize the available energy of the coil by maintaining the Delta T. In addition to the standard analog signal and feedback wiring, it communicates its data to the building management system via BACnet MS/TP or BACnet IP. The built-in web server collects up to 13 months of data that can be downloaded to external tools for further optimization. Some of these features contribute to LEED points.

  • TDS/Conductivity And PH Testing Instruments

    DS & pDS Meters™ - Myron L Company

    No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications.

  • ION 100 Portable Ion Meter

    OAKTON Instruments

    The new addition to the Environmental Express Oakton product line features updates to measuring water quality easier and faster. The larger LCD display is 2.75 in. by 2.0 in. for a better viewing angle, and has indicators for battery life, stability, and calibration. The ION 100 meter measures pH, mV, ion concentration of 16 commonly measured ions, and temperature. The microprocessor-based meter features automatic calibration, automatic temperature compensation, function setup, self-diagnostics, automatic power-off, and low voltage display. The meter uses advanced digital processing technology, intelligently improving the response time and accuracy of your measurements. Easily switch units among pX, mol/L, and mg/L (ppm).

  • Ancillary Test Cell Products

    SAKOR Technologies, Inc.

    In addition to our innovative and industry leading AccuDyne AC Dynamometers and DynoLAB Test Automation Systems, SAKOR fully integrates a complete range of ancillary products and subsystems necessary for an advanced test cell. Examples include:*Combustion air consumption measurement and conditioning subsystems*Exhaust handling systems*Fuel consumption measurement and conditioning subsystems*Coolant and oil conditioning systems*Throttle actuators*Spark/Fuel controls*Combustion analysis systems*Complete exhaust emissions analysis systems (per 40 CFR 1065 regulations)*Sound attenuating (up to STC 52) test cell enclosures with several fire suppression options*Process water evaporative cooling tower

  • Gas Filter Correlation CO​​​​ Analyzer

    ​Model N300 - Teledyne Advanced Pollution Instrumentation

    The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

  • Digestion Systems

    Tecator line - FOSS A/S

    FOSS Tecator line Digestion systems are based on a digestion unit and a tube rack, allowing fully automated digestion for convenient, safe and flexible Kjeldahl analysis. Two way PC communication supports traceability and GLP. These versatile digestion systems are capable of handling eight, twenty or forty tubes in volumes of 100 ml, 250 ml or 400 ml dependent on chosen configuration. Parameters: Kjeldahl digestions, Chemical Oxygen Demand & other reflux chemistries, Trace metal analysis by AAS or ICP instruments. Sample types: Raw materials and finished products in Food, Feed, Agriculture and related matrices, Water & Wastewater and a wide range of industrial compounds.

  • Pressure Sensors

    TE Connectivity Ltd.

    A pressure sensor is a device that senses pressure and converts it into an electric signal where the amount depends upon the pressure applied. TE Connectivity (TE) designs and manufactures pressure sensors ranging from the sensing element to system packaging for harsh environments. We are an industry leader for our range of both standard and custom pressure sensors, from board level components to fully amplified and packaged transducers. Based on piezoresistive Micro-electromechanical systems (MEMS) and silicon strain gauge (Microfused, Krystal Bond) technology, our sensors measure everything from less than one inch of water column (<1.25 mbar) to 100K psi (7K bar).

  • Deep Submersible Particle Size Analyzer

    LISST-Deep - Sequoia Scientific, Inc.

    The LISST-DEEP instrument obtains in-situmeasurements of particle size distribution,optical transmission, and the opticalvolume scattering function (VSF). Using ared 670nm diode laser and a customsilicon detector, small-angle scatteringfrom suspended particles is sensed at 32specific log-spaced angle ranges. Thismeasurement is post-processed to obtainsediment size distribution, volumeconcentration, optical transmission, andVSF. The electronics and opticalconfiguration in the LISST-DEEP are verysimilar to Sequoia’s workhorse, the LISST-100X. However, because of the extremedifficulty associated with keepingalignment under high pressure, the LISSTDEEPhardware design is radically differentfrom the LISST-100X. This allows theLISST-DEEP to be deployed down to 3000m and obtain reliable measurements ofthe in situ particle size distribution andvolume concentration in waters withoptical transmission up to 98.5%.

  • Field Machine

    ACM Instruments

    The Portable Field Machine is our most versatile full specification corrosion testing instrument. Its rugged construction and protective water resistance IP68 enclosure enables it to be operated at extreme locations throughout the world. This instrument takes laboratory precision outdoors to oil rigs, pipelines, concrete walls and just about anything that needs corrosion monitoring in situ. The potentiostat, ZRA, integral Frequency Response Analyser and Sweep Generator are exactly as provided in the laboratory Gill 8 model ensuring the most accurate testing available. The choice of tests is not limited; the AC, IR Compensation and DC tests plus the Sequencer and Analysis that are supplied with this field instrument are the same as supplied with the laboratory instruments.

Get Help