  • Fluids Resistance Testing

    National Technical Systems

    NTS has extensive abilities in fluid testing. We’ve tested a large variety of products, from pipe fittings to process controllers, flexhoses to pressure vessels, valves to actuators, tank liners to heat exchangers, water to Skydrol. We have tested these products for a variety of measurements, from viscosity to flash point and auto ignition, among others. NTS fluids testing facilities are equipped with computerized data acquisition, reduction and analysis equipment for monitoring the functional characteristics of specimens during testing. NTS has considerable expertise in high flow testing of small devices – such as meters, indicators, totalizers, sensors, transmitters, and check valves.

  • Highest Precision Pure Gas Analyzer

    iso DUAL INLET - Elementar Analysensysteme GmbH

    Dual inlet technology is the most precise, accurate and sensitive technique for carbonate and water analysis. Because of this, the iso DUAL INLET has a unique role in the paleoclimate applications where instrumental precision contributes directly to the precision of paleoclimate models. Whilst the world's climate continues to behave erratically, we must know what has happened in Earth's history before we can attempt to predict what will happen in the future. To elucidate this complicated story, the iso DUAL INLET is a valuable tool for paleoclimatologists to build a detailed picture of the past to better inform policy makers who might just be able to influence the future of our planet.

  • Linear Actuators

    Electrak Pro - Thomson

    Thomson introduces our Electrak Pro Series of linear actuators. This family stands alone when it comes to the toughest and most demanding applications. Available in 12 or 24 VDC models with customizable stroke lengths up to 300 mm (12 in), these units can push or pull loads up to 4448 N (1000 lbf) at speeds of 20 mm/s (0.8 in/s) and hold loads up to 9000 N (2000 lbf), or contact our factory for longer strokes or higher loads. When space is scarce, where dust, dirt, and water are abundant and when solid, reliable and maintenance-free operation is a must - Electrak Pro is the answer.

  • Mid-Range Gas Filter Correlation CO Analyzer

    Model N300M - Teledyne Advanced Pollution Instrumentation

    The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

  • Milk Analyzers

    MRC ltd.

    Measuring parameters: FAT 0.01% - 25%SNF 3% - 15%Density 1015 1040kg/m3Proteins 2% - 7%Lactose 0.01% - 6%Water content 0% - 70%Temp. of milk 1C 40CFreezing point - -0.400 0.700CSolids 0.4 1.5%1. Sample visualization onLCD display(green)2. Possibility to measure 1 sample 90 seconds(option 60 seconds)3. Adapter 220-110 V 4.Spare silicone tubes5. Syringe6. Plastic sample holder7. Calibrations Cow, Sheep, and UHT milk8. Operation Manual9. Cardboard transport case10. CD Service PackMeasuring time 30s

  • Petroleum Testing Solutions

    Labodam

    Acid andalkali testers, aniline test equipment, automatic bomb calorimeters, automatic dielectric tester, closed cup flash point tester, demulsibility characteristics tester, density tester, distillation tester, dropping point tester, engler viscometer, existent gum tester, kinematics viscometer, low temperature tester, octant number and cetane number tester, open cup flash point tester, oxidation stability tester, oxygen bomb calorimeter, penetrometer, residue carbon, rotational viscometer, rust and corrosion tester, specific gravity tester, sulphur content tester, vapor pressure, water content tester.

  • Premium Multispectral Marine Camera with Stabilization and Extended Range

    M364C LR - Teledyne FLIR

    Featuring a high definition low light camera and one of the most advanced FLIR thermal imaging cores, the M364C-LR provides an elite level of awareness on the water. The M364C LR uses multispectral imaging to deliver exclusive FLIR Color Thermal Vision™ (CTV) technology. Color Thermal Vision blends visible camera details with a thermal image, allowing captains to positively identify navigation aids and other vessels within the thermal scene. Outstanding imaging performance, a narrow field of view lens for extended range performance, and gyro-stabilization make the M364C LR an indispensable tool for law enforcement professionals and commercial mariners.

  • Pressure Temperature Sensors

    Teledyne Marine Cormon

    The PT sensor has been designed to the highest industry standards to provide customers with dependable and accurate measurement of temperature (+/- 0.50C) and pressure (0.025% FSD) within a high integrity mechanical package. The sensor is available in both 10k and 15k psi configurations and incorporates true dual redundant sensors and electronics. Combined with the addition of a tertiary barrier between the process fluid and sea water, operators and users can be assured of high integrity data with a design life of >25 years. The unit offers operators flexible communications interfaces as standard covering CANbus (CiA443, SIIS Level 2), MODbus (RS485) or 4-20mA outputs.

  • UV Testing Machine

    Dongguan Kejian Instrument Co., Ltd.

    1. Meet ISO,ASTM, DIN,JIS,SAE,BS,ANSI,GM,U.S.GOVT(ASTMG153,ASTMG154,,ASTMD4329,ASTMD4977,ASTMD4587,SAEJ2020,ISO4892)2. QUV condensation device simulates the effect of humidity of outdoor,meeting 100% humidity.3. Electronic-eye irradiance control system4. Use blackboard temperature sensor providing precise temperature and recuring test result.5. Perform humidifying, condensation and water spraying circulating test.6. Irradiance is calibrated by CR-10 calibrator and automatic calebration procedure.(Paten technology)7. Specimen size and quantity: 75mm×300mm 24pcs, 75mm×150mm 48pcs

  • Quad Input Logging Thermometer

    DT304 - UEi Test & Measurement Instruments

    This series of Digital Thermometers offers a unique combination of features including logging capabilities with 9,999 memory positions and a USB interface and software, one, two and four inputs offering relative and differential readings. The Apollo also offers a solution to storing probes and is manufactured to conform to the IP67 standard, meeting performance expectations of water submersion and high-pressure dust resistance

  • Dual Input Logging Thermometer

    DT302 - UEi Test & Measurement Instruments

    This series of Digital Thermometers offers a unique combination of features including logging capabilities with 9,999 memory positions and a USB interface and software, one, two and four inputs offering relative and differential readings. The Apollo also offers a solution to storing probes and is manufactured to conform to the IP67 standard, meeting performance expectations of water submersion and high-pressure dust resistance.

  • Electromagnetic (EM) Speed Log System

    AGILOG 2 - Aeronautical & General Instruments Ltd.

    AGILOG 2 is based on the well-established electromagnetic principle that a voltage is induced in a conductor by a moving magnetic field. By using the sea water as a conductor, an output is generated as the vessel progresses. Electromagnetic speed measurement is passive in operation and therefore particularly suitable for use in submarines and warships. The EM technology provides reliable and robust speed availability when compared to some alternative technologies.

  • TDS/Conductivity And PH Testing Instruments

    DS & pDS Meters™ - Myron L Company

    No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L® Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications.

  • Electrochemical Migration (ECM) Testing

    National Technical Systems

    Testing for electrochemical migration (ECM) would occur in the case of a field failure return. Metal migration between isolated conductors on a completed printed circuit assembly may produce electrical shorts.Why does this growth occur and what do you need to look for? Basically, we need to know if our assemblies are “dirty.” By dirty, we mean littered with ions. Ions on printed circuit assembly surfaces can cause short circuits. In simple terms, shorts occur when the space between the conductors is bridged by dendrites formed by re-deposited metal ions. This metal migration is best described by IPC as a reverse plating of the conductors in the presence of ions, water and an electrical potential.

  • Boat Mount Sonar Scanner with P&T

    Teledyne Marine BlueView

    Deployed from a patrol boat, Teledyne BlueView's BV3100 is ideal for search and recovery operations, dive team situational awareness, and diver vectoring. It is also an effective means of harbor bottom inspection as well as diver and underwater IED detection.The BV3100 uses Teledyne BlueView's 2D forward looking sonar mounted to a digital pan and tilt system to deliver clear, streaming imagery during both confined and wide area searches. This real-time imagery is produced whether moving or stationary, even in zero visibility water conditions. The BV3100 can be used alone or as a complement to side scan sonar by allowing the user to reacquire and guide divers to targets found in side scan imagery.