Filter Results By:

Products

Applications

Manufacturers

Showing product results. 1216 - 1230 of 1429 products found.

  • ASAP® Probe

    IonSense Inc.

    Atmospheric Solids Analysis Probe (ASAP®) mass spectrometry allows direct analysis of samples using an atmospheric pressure ionization (API) source found on Liquid Chromatography Mass Spctrometry (LCMS) instruments. The ASAP® probe permits fast analysis of solid, liquid, tissue, or material (e.g. polymer) samples. ASAP® is a low cost alternative ionization method that is especially useful on commercial high end API mass spectrometers which have the capability of accurate mass and mass-selected fragmentation, such as a Bruker Qh-FTMS™, Jeol AccuTOF™, Thermo Ortitrap™, or Waters Synapt HDMS™.

  • IP X3, X4 - Rain Test Chamber

    ACMAS Technocracy Pvt. Ltd.

    The rain water or moisture penetrating through a leak in the case, can often reach into the circuit board and lead to failure of the equipment. This problem is frequently encountered with external equipments and devices during storage, usage or transportation in a rainy weather. Therefore, the automotive industries and various research and developmental units often use Rain Test Chambers to test the quality and performance of the product in such extreme environments.Weiber's Rain Test Chambers are such Rain Testing Machines/Chambers used for the testing of automobiles, electronic parts and components, light equipments, voltage cabinets and other wide variety of products under a rainy environment. These IP Test Chamber and IP Testing Chambers are designed to simulate specific environmental conditions, mimicking a natural rainy weather, to test the seals and water proofing capacity of the equipment and devices, thereby providing an estimation of the product performance over a period of time.

  • Electromagnetic (EM) Speed Log System

    AGILOG 2 - Aeronautical & General Instruments Ltd.

    AGILOG 2 is based on the well-established electromagnetic principle that a voltage is induced in a conductor by a moving magnetic field. By using the sea water as a conductor, an output is generated as the vessel progresses. Electromagnetic speed measurement is passive in operation and therefore particularly suitable for use in submarines and warships. The EM technology provides reliable and robust speed availability when compared to some alternative technologies.

  • Quad Input Logging Thermometer

    DT304 - UEi Test & Measurement Instruments

    This series of Digital Thermometers offers a unique combination of features including logging capabilities with 9,999 memory positions and a USB interface and software, one, two and four inputs offering relative and differential readings. The Apollo also offers a solution to storing probes and is manufactured to conform to the IP67 standard, meeting performance expectations of water submersion and high-pressure dust resistance

  • Dual Input Logging Thermometer

    DT302 - UEi Test & Measurement Instruments

    This series of Digital Thermometers offers a unique combination of features including logging capabilities with 9,999 memory positions and a USB interface and software, one, two and four inputs offering relative and differential readings. The Apollo also offers a solution to storing probes and is manufactured to conform to the IP67 standard, meeting performance expectations of water submersion and high-pressure dust resistance.

  • Moisture In Hydrocarbon Liquid Analyzers

    Process Sensing Technologies

    Ultra-dry conditions are essential for many petrochemical processes and refineries. The Liquidew moisture in liquid analyzers boosts quality and efficiency through continuous, online measurements of moisture dissolved in a wide variety of non-polar liquids. Typical applications include monitoring moisture content in naphtha feedstock to isomerisation processes and avoiding liquid water phase separation in diesel and aviation fuels.

  • Clora Online

    XOS

    Chlorine is often present in crude oils and the concentration can vary greatly depending on the origin. If not removed, Chlorine can react to form highly corrosive hydrochloric acid in areas such as crude tower overheads, leading to serious operational issues, economic loss and safety concerns. The need for a reliable online chlorine analyzer for refining process control is more important than ever. Clora Online complies with ASTM D7536 method, and delivers continuous chlorine analysis to monitor plant equipment corrosion. By monitoring desalted crude, a plant can optimize performance and immediately see impacts of crude changes (including organic chloride). Additionally, monitoring overhead water can provide the necessary feedback for chemical feed.

  • Deep Submersible Particle Size Analyzer

    LISST-Deep - Sequoia Scientific, Inc.

    The LISST-DEEP instrument obtains in-situmeasurements of particle size distribution,optical transmission, and the opticalvolume scattering function (VSF). Using ared 670nm diode laser and a customsilicon detector, small-angle scatteringfrom suspended particles is sensed at 32specific log-spaced angle ranges. Thismeasurement is post-processed to obtainsediment size distribution, volumeconcentration, optical transmission, andVSF. The electronics and opticalconfiguration in the LISST-DEEP are verysimilar to Sequoia’s workhorse, the LISST-100X. However, because of the extremedifficulty associated with keepingalignment under high pressure, the LISSTDEEPhardware design is radically differentfrom the LISST-100X. This allows theLISST-DEEP to be deployed down to 3000m and obtain reliable measurements ofthe in situ particle size distribution andvolume concentration in waters withoptical transmission up to 98.5%.

  • Digestion Systems

    Tecator line - FOSS A/S

    FOSS Tecator line Digestion systems are based on a digestion unit and a tube rack, allowing fully automated digestion for convenient, safe and flexible Kjeldahl analysis. Two way PC communication supports traceability and GLP. These versatile digestion systems are capable of handling eight, twenty or forty tubes in volumes of 100 ml, 250 ml or 400 ml dependent on chosen configuration. Parameters: Kjeldahl digestions, Chemical Oxygen Demand & other reflux chemistries, Trace metal analysis by AAS or ICP instruments. Sample types: Raw materials and finished products in Food, Feed, Agriculture and related matrices, Water & Wastewater and a wide range of industrial compounds.

  • Drying Ovens

    Dongguan Amade Instruments Technology Co., Ltd

    Drying oven is divided into fan blown type electric drying oven and vacuum drying oven based on the different materials which are dried. Electric drying oven is an oven with circulating air function to dry materials containing water by the way of electrical heating. Vacuum drying oven is a instrument provides vacuum environment for specially heat dry heat-sensitive, easily decomposed and easily oxidized materials. Working chamber is vacuumed by vacuum pump prior to drying, allowing to be filled with inert gas If necessary. Drying cabinets are widely used in chemical industry, electronic communication, plastics, cables, hardware, automobile parts, rubbers, printing, medical products, academy laboratories etc.

  • Gas Filter Correlation CO​​​​ Analyzer

    ​Model N300 - Teledyne Advanced Pollution Instrumentation

    The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

  • Pressure Data Loggers & Transmitters

    Monarch Instrument

    The Track-It Pressure Transmitter/Data Loggers with Digital Display are 24Vdc powered 4 wire transmitters that can also record up to 130,000 samples for logging, redundant data backup or archive. They can be configured to record both pressure or vacuum and ambient temperature or just pressure or vacuum alone to maximize data storage space. The Track-It™ Pressure/Temperature and Vacuum/Temperature Data Loggers with Display are battery powered stand alone water tight compact data loggers that record up to 130,000 samples. Simply plug the data logger into an available USB port on your PC and customize the settings, transfer data or view data in real time with the included Track-It Software program.

  • Professional Mobile Photometer

    P34 - Evoqua Water Technologies LLC

    The photometer P34 Professional meets all the requirements of modern water analysis. The device has a backlit display. Measuring range, reagent type as well as an automatic countdown timer for accurate response times are displayed. The internal memory stores up to 1,000 events with date, time and sample ID. The data can be retrieved at any time and transferred via an optional infrared module. The photometer P34 Professional serves, among others, to detect alkalinity, aluminum, bromine, chlorine, chlorine dioxide, chlorite, cyanuric acid, iron, urea, hardness, iodine, copper, sodium hypochlorite, ozone, PHMB, phosphate, pH, oxygen, acid, sulphate and hydrogen peroxide using various methods.

  • Rotational Flow Demonstration Kit

    Renesas Electronics Corp.

    The rotational flow demonstration kit detects the rotational position using the MCU’s on board data transfer controller (DTC) function, a form of state machine, while the MCU’s core is in stop-mode state. This ensures that the average power consumption is kept as low as possible, with IAV (average current) at 4.5 microampere (μA) and a 32 sample burst per second. The flow demonstration kit senses the flow direction and volumetric flow rate of water and gas, and can also detect reverse flow. The demonstration kit is applied using an active inductive method. Two coils are used to sense the rotational position of a part-metalized disk, and a third coil is used to generate a reference signal.

  • Electrochemical Migration (ECM) Testing

    National Technical Systems

    Testing for electrochemical migration (ECM) would occur in the case of a field failure return. Metal migration between isolated conductors on a completed printed circuit assembly may produce electrical shorts.Why does this growth occur and what do you need to look for? Basically, we need to know if our assemblies are “dirty.” By dirty, we mean littered with ions. Ions on printed circuit assembly surfaces can cause short circuits. In simple terms, shorts occur when the space between the conductors is bridged by dendrites formed by re-deposited metal ions. This metal migration is best described by IPC as a reverse plating of the conductors in the presence of ions, water and an electrical potential.

Get Help