Filter Results By:

Products

Applications

Manufacturers

Showing product results. 1186 - 1200 of 1410 products found.

  • Pyrgeometers / Four-Component Radiometer

    EKO Instruments Co., Ltd.

    EKO's pyrgeometers and net radiometers are used for meteorological observations of atmospheric radiations (radiations from clouds, water vapor, CO2 etc.) and the net radiation exchange between the earth and the atmosphere. Net total irradiance (shortwave + longwave) is typically measured by 4 component net radiometers or single component pyradiometers which have a single detector covering the full range. Pyrgeometers measure the long wave down welling radiation by means of a single detector facing the atmosphere. The Net longwave and down welling radiation can be determined by calculation.

  • Riverboat SP

    Teledyne Marine RD Instruments

    The Riverboat SP is the top choice for deployment of the Teledyne RDI StreamPro acoustic Doppler current profiler. Upgrade from the standard StreamPro float to the more stable, rugged and fully corrosion-resistant tethered boat. The Riverboat SP makes safe, easy measurements of discharge in relatively slow and fast flowing waters. Made of unbreakable polyethylene, the Riverboat SP is strong and can handle tough deployment conditions. The standard boat configuration fits a TRDI StreamPro ADCP, and the latest instrument clamp is suitable for the StreamPro with or without an internal compass upgrade.

  • Single Beam Echosounder, Hydrographic Survey Boat

    Z-Boat 1250 - Teledyne Marine Oceanscience

    Teledyne Oceanscience Z-Boats® are the number one choice for reliable, remotely controlled, hydrographic surveying in streams, rivers, lakes, and coastal waters around the world.Whether you need to reduce survey time, keep people safe during hazardous conditions, or access hard to reach locations, there is a Z-Boat to suit your survey and your budget. The Z-Boat 1250 is easy to operate. The integrated echosounder has an embedded transceiver with digital signal processing and outputs depth & temperature using NMEA 0183 data output.

  • Workhorse Quartermaster

    Teledyne Marine RD Instruments

    RDI's 150 kHz QuarterMaster ADCP has been designed to fill a gap between our 300 kHz Workhorse ADCPs and our 75 kHz Workhorse Long Ranger. This unit offers an extended current profiling range over our higher frequency units, in our proven Long Ranger configuration. The Quartermaster is ideally suited for applications in which you're interested in measuring the top 300 meters of the water column. The highly versatile QuarterMaster can also be upgraded to include our bottom tracking option.

  • Heavy Duty Dynamometers

    MD-7500-HD - Mustang Dynamometer

    Today’s Fleet Managers are faced with many challenges – most important of which is maintaining a healthy bottom line. With fuel costs at an all-time high, these challenges have become increasing difficult. Fleets being transitioned from fossil fuels to electric propulsion also face challenges with durability and range to make sure routes can be completed on time each and every day. To help combat these problems and others facing fleet managers today, Mustang Dynamometer offers the MD-7500-HD Series Chassis Dynamometer – which features the most advanced diagnostic capabilities in the industry. The MD-7500-HD is designed to simulate the driving conditions that fleet vehicles encounter on the road every day in a safe and controlled shop floor environment so that critical engine and drivetrain systems can be evaluated to insure vehicles are performing properly and at maximum efficiency. What’s more, the MD-7500-HD offers several levels of testing capabilities in a modular, compact package and with capabilities that can be upgraded in the future as your needs change. Every vehicle in your fleet can now be tested and validated before and after a repair to ensure proper diagnosis and repairs have been performed. In addition to testing repaired vehicles, the MD-7500-HD can be used to test vehicles on a regular basis as a preventative maintenance measure which decreases unexpected breakdowns and allows fleet management to control fuel costs while reducing repair costs. Periodic testing keeps fuel consumption to a minimum and helps technicians identify suspect components before they fail. A proactive approach to Fleet Service can prevent unexpected engine and or drive-train failure which saves organizations thousands of dollars in lost fair revenues. At the heart of the MD-7500-HD is a set of three air-cooled eddy current power absorbers. Each absorber, or brake, can hold up to 600-hp (total power of 1,800-hp) – more than enough to simulate a fully loaded transit bus. As the systems PAU’s (brakes) are air-cooled, no water is required to or from the device – eliminating the high cost of water consumption and/or the cost of an expensive water recovery system – which can sometimes exceed the cost of the dynamometer system itself. Mustang is the only company that offers a Universal Fleet Test Bed without water supply requirements. AC Motors can be added to simulate regeneration and validate range for organizations that have transitioned to carbon free electric propulsion. The 7500 is the best solution for fleet managers looking to improve their bottom line and offer disruption-free public transportation.

  • Flow Sensors and In-Line Flow Switches

    TE Connectivity Ltd.

    TE Connectivity (TE) manufactures flow sensors suitable for various liquids. Designed for applications including water control, power shower, central heating systems, circulation pump protection, cooling and leak detection, our in-line flow switches and sensors offer various fittings for simple installation.

  • 600 kHz Phased Array DVL

    Pathfinder - Teledyne Marine RD Instruments

    Doppler Velocity Log provides an array of advanced internal algorithms and features you’d typically expect to find only in higher-end solutions. With up to 80 m of bottom tracking, in up to 300 m of water, the Pathfinder 600 delivers a solid, value-priced solution for vehicles ranging from small inspection class ROVs to large diameter AUVs. bottom-detection algorithms and single-ping bottom-location accuracy with its broadband velocity processing technology, the Pathfinder provides users with highly reliable precision velocity data for navigation and position control, even over indeterminate terrain.

  • BOD (Biochemical Oxygen Demand)

    MRC ltd.

    The role of Biochemical Oxygen Demand (BOD) is to measure the amount of oxygen needed to remove organic waste from the water of bacteria.Important to know, the larger the Biochemical Oxygen Demand, the more rapidly oxygen is depleted in the stream. This means there will be less oxygen in the water.biological oxygen demand is essential By providing information to assess the effect discharged wastewater will have on the receiving environment.The BOD value is commonly expressed in milligrams of oxygen consumed per liter of sample during 5 days of incubation at 20°C.The goal is maintaining the aquatic life and aesthetic quality of streams and lakes.

  • Climate Chamber

    ICH - Memmert GmbH + Co.KG

    Its excellent temperature and humidity homogeneity positions the climate chamber ICH in the international top league of stability test chambers. Thermal transfer to the interior whether heat or cold is guaranteed through a large-area air jacket on four sides. Thanks to its hermetically sealed interior, the climate chamber ICH does not consume any water once the setpoints have been reached, provided that the door is not opened. Two high-grade platinum temperature sensors with mutual monitoring guarantee interruption-free long-term operation even if one sensor should fail.

  • Differential Pressure Manometer (0.5psi)

    HD755 - Extech Instruments Corporation

    Offering 11 selectable units of measure, the HD755 Differential Pressure Manometer can serve as a low range/high resolution Gauge or provide Differential Pressure up to 0 to 13.85 in. H2O (inches of water). Max/Min recording and Relative time stamp are useful features, as are HD755's Data Hold and Auto Power Off functions. The 0.5psi HD755 also features Zero function for offset correction or measurement and a built-in USB interface. Comes complete with 9V battery, software with USB cable, AC Adaptor, connection hose, built-in stand, and hard carrying case.

  • Differential Pressure Manometer (2psi)

    HD700 - Extech Instruments Corporation

    Offering 11 selectable units of measure, the HD700 Differential Pressure Manometer can serve as a low range/high resolution Gauge or provide Differential Pressure up to 0 to 55.40 in. H2O (inches of water). Max/Min recording and Relative time stamp are useful features, as are HD700's Data Hold and Auto Power Off functions. The 2psi HD700 also features Zero function for offset correction or measurement and a built-in USB interface. Comes complete with 9V battery, software with USB cable, AC Adaptor, connection hose, built-in stand, and hard carrying case.

  • Differential Pressure Manometer (5psi)

    HD750 - Extech Instruments Corporation

    Offering 11 selectable units of measure, the HD750 Differential Pressure Manometer can serve as a low range/high resolution Gauge or provide Differential Pressure up to 0 to 138.3 in. H2O (inches of water). Max/Min recording and Relative time stamp are useful features, as are HD750's Data Hold and Auto Power Off functions. The 5psi HD750 also features Zero function for offset correction or measurement and a built-in USB interface. Comes complete with 9V battery, software with USB cable, AC Adaptor, connection hose, built-in stand, and hard carrying case.

  • Earth Magnetometer

    EM2 - Alpha Lab, Inc.

    The Earth Magnetometer Model EM2 measures small variations from location to location in the Earth magnetic field associated with buried magnetic masses. Unlike metal detectors, a magnetometer signal is not attenuated by rock, dirt, mud or water, so targets can be detected at great depth. (If D is the diameter of a mass of magnetizable material, the EM2 can detect it as deep as 40 times the diameter D, whether the mass is specifically magnetized or not.) It is the lightest weight and lowest cost magnetometer available which can reliably measure differences down to 1 nT from point to point.

  • Exacting Electric Motor Testing

    Taylor Dynamometer, Inc.

    The Taylor Dynamometer Electric Motor Test Stand is designed to provide maximum reliability, excellent durability and flawless performance. Using our extensive line of Water Brake engine dynamometers, Taylor Dynamometer has systems available for testing electric motors from 5 to 13,000 hp (3.7 to 9,694 kW). Include an instrumentation package to achieve your testing requirements. From simple speed, torque and power display systems with manual control to completely automated testing solutions, Taylor Dynamometer has a system to meet your testing requirements.

  • Flow Cytometer

    INO

    Nowadays, quality control is a key part of any industrial process, in line with dynamically changing standards, and creation of new standards and protocols in accordance to each industry. Flow cytometry is a widely used bioanalysis technique in a larger number of applications. Extensively used in fields like microbiology, the technology has also proven benefits in the food and agrifood industry. A potential application is the absolute somatic cells count in the milk. Flow cytometry can also be applied for environmental and sanitary microbiology for applications such as detection of bacterial cells in milk or water for quality control and assurance testing.